Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/28257
Full metadata record
DC FieldValueLanguage
dc.creator.IDJERONIMO, E.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/7432737015287372pt_BR
dc.contributor.advisor1AMORIM JUNIOR, Wanderley Ferreira de.-
dc.contributor.advisor1IDAMORIM JUNIOR, W. F.npt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/8131607733881361pt_BR
dc.contributor.advisor2SANTANA, Renato Alexandre Costa de.-
dc.contributor.advisor2IDSANTANA, R. A. C.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/1438381290031148pt_BR
dc.contributor.referee1FERNANDES, Eisenhawer de Moura.-
dc.contributor.referee1IDFERNANDES, E. M.pt_BR
dc.contributor.referee2COUTINHO, Sebastião Araújo.-
dc.contributor.referee2IDCOUTINHO, S. A.pt_BR
dc.description.resumoUm sistema de bombeamento de fluxo pulsátil permite replicar as formas de onda de fluxo hidráulico, com precisão razoável para diversas simulações, como por exemplos fluxos sanguíneos fisiológicos, fluxos hidráulicos de sistemas de baixa pressão, etc. Uma aplicação importante desse sistema é permitir a simulação do fluxo sanguíneo do corpo humano permitindo a análise da mecânica dos fluidos do sistema circulatório humano, com um controle de variáveis como pressão, temperatura e ciclos por minuto, podendo-se ter uma condição muito próxima da realidade, além de permitir criar diversas situações distintas modificando os valores das variáveis mencionadas anteriormente. Para análise de Stents cardiovasculares, por exemplo, a Norma ASTM 2477-7 recomenda que os testes sejam feitos em condições semelhantes aquelas de uso, ou seja, em fluxo pulsátil simulando o coração humano. Stent é um dispositivo médico que pode ser definido como um cilindro de metal ou polímero, geralmente em forma de rede, que é colocado no lúmen de um vaso anatômico (como uma artéria ou um duto biliar) com o objetivo de reabrir a passagem desse vaso que encontra-se total ou parcialmente obstruída, geralmente com o intuito de manter um normal fluxo do sangue. Em virtude de sua aplicação influenciar diretamente a saúde do paciente, tem-se à necessidade de pesquisar formas de melhorar as propriedades físicas e químicas, tornando a tecnologia dos Stents mais confiável sem comprometer a biocompatibilidade. Assim, o presente trabalho, propõe o desenvolvimento de uma bancada experimental de fluxo pulsátil que poderá ser usada para ensaios em Stents. O projeto foi dividido em duas partes, a primeira foi o planejamento e fabricação da bancada (Projeto conceitual e mecânico) e em um segundo momento, a instrumentação da mesma (Projeto eletrônico). Como subsídio do projeto foram estudadas diversas bancadas geradoras fluxo pulsátil (que simulam o coração humano) e a partir desses, concebida e fabricada uma bancada que trabalha com fluido escoando em ciclo fechado. A mesma é composta por um atuador linear (Gerador de Pulso) e vários elementos sensores que permitem o sistema trabalhar em malha fechada, com controle de temperatura, pressão e número de ciclos por minuto. Todos os dados gerados são armazenados em um banco de dados podendo ser monitorados remotamente via web. Para análise, o corpo de prova é colocado no interior do tudo ou em uma célula de ensaio e um fluido, é circulado de forma pulsátil pelas mangueiras.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Ciências e Tecnologia - CCTpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA MECÂNICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Mecânica.pt_BR
dc.titleProjeto, fabricação e testes de uma bancada experimental de fluxo pulsátil.pt_BR
dc.date.issued2015-08-28-
dc.description.abstractA pulsatile flow pumping system allows replicating forms hydraulic flow wave, with reasonable accuracy for various simulations, for example physiological blood flows, inflows of low pressure hydraulic systems, etc. An important application of this system is to enable simulation of blood flow in the human body allowing the analysis of the mechanics of the human circulatory system fluids, with a control variable such as pressure, temperature and cycles per minute, being able to have a very next condition reality, and allows creating many different situations modifying the values of the variables mentioned above. For analysis of cardiovascular stents, for example, ASTM 2477-7 recommended that tests be conducted under conditions similar to those of use, ie in pulsatile flow simulating human heart. The stent is a medical device that can be defined as a metal cylinder or polymer, usually in network form, which is placed in the lumen of an anatomical vessel (such as an artery or a bile duct) in order to reopen the passage of this vessel which is fully or partially obstructed, usually in order to maintain a normal blood flow. Because of its application directly influence the health of the patient, there is the need to search for ways to improve the physical and chemical properties, making the most reliable technology of stents without sacrificing the biocompatibility. Thus, this paper proposes the development of a pulsatile flow test rig that can be used for testing on stents. The project was divided into two stages, the first was the design and craftsmanship of the bench (Conceptual Design and Mechanical) and in a second step, the same instrumentation (electronic design). As project grant were studied various pulsatile flow generating benches (which simulate the human heart) and from the these, designed and manufactured a bench working with leaking fluid in a closed cycle. The same consists of a linear actuator (Pulse Generator) and several sensor elements that allow the system to work in closed loop, with temperature control, pressure and number of cycles per minute. All data generated is stored in a database and can be monitored remotely via the web. For analysis, the test body is placed inside all or a test cell, and a fluid is circulated through the tubes pulsatile.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/28257-
dc.date.accessioned2022-12-09T21:53:35Z-
dc.date.available2022-12-09-
dc.date.available2022-12-09T21:53:35Z-
dc.typeDissertaçãopt_BR
dc.subjectBancada experimental de fluxo pulsátilpt_BR
dc.subjectFluxo pulsátilpt_BR
dc.subjectFluxo em malha fechadapt_BR
dc.subjectStents cardiovascularespt_BR
dc.subjectNorma ASTM 2477-07pt_BR
dc.subjectCiclo cardíacopt_BR
dc.subjectSistema de bombeamento de fluxo pulsátilpt_BR
dc.subjectExperimental pulsatile flow benchpt_BR
dc.subjectPulsatile flowpt_BR
dc.subjectClosed loop flowpt_BR
dc.subjectCardiovascular stentspt_BR
dc.subjectASTM Standard 2477-07pt_BR
dc.subjectCardiac cyclept_BR
dc.subjectPulsed flow pumping systempt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorJERONIMO, Emerson.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeDesign, fabrication and testing of an experimental pulsatile flow bench.pt_BR
dc.identifier.citationJERONIMO, Emerson. Projeto, fabricação e testes de uma bancada experimental de fluxo pulsátil. 2015. 106f. (Dissertação de Mestrado) Programa de Pós-Graduação em Engenharia Mecânica, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande - Paraíba - Brasil, 2015. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/28257pt_BR
Appears in Collections:Mestrado em Engenharia Mecânica.

Files in This Item:
File Description SizeFormat 
EMERSON JERONIMO - DISSERTAÇÃO PPGEM CCT 2015.pdfEmerson Jeronimo - Dissertação PPGEM CCT 201520.98 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.