dc.description.resumoEste trabalho teve por objetivo estudar o consumo per capita, os coeficientes de variação de consumo de água e contribuição de esgoto, da população de baixa renda dos Conjuntos Habitacionais Glória I e Glória II, na cidade de Campina Grande-PB (7013’11”Sul, 35052’31”Oeste), que abrigaram 2304 habitantes transferidos da extinta Favela da Cachoeira. Os conjuntos são dotados de infra-estrutura básica de saneamento, drenagem, pavimentação, energia elétrica, telefonia, coleta de lixo e transporte coletivo. O sistema de abastecimento de água é composto de um alimentador (DN-150mm) transportando uma vazão de 8,38 l/s; estação elevatória (5,13 l/s), sub-adutora de recalque (DN-100mm) e reservatório elevado (100m3) para o Glória I; e sistemas de distribuição. O sistema de esgotamento sanitário é composto de sistemas coletores (DN-100 e 150mm), dois emissários de gravidade (DN- 150mm) e o sistema de tratamento, projetado para tratar também os esgotos dos bairros Belo Monte e Jardim América, dotado de tratamento preliminar, duas lagoas em série, uma anaeróbia e uma facultativa com um vertedor triangular instalado aonde sai o efluente. Entre novembro de 2006 e fevereiro de 2007 foram feitas 4152 e 744 leituras horárias de consumo de água e de vazão de contribuição de esgotos, respectivamente, para estudar as tendências das estimativas do consumo per capita (q), do coeficiente do dia de maior consumo (K1), do coeficiente da hora de maior consumo (K2) e do coeficiente de retorno esgoto/água (C). O estudo mostrou que o consumo médio per capita atual (90 l/hab.dia) é igual para os dois conjuntos e menor que o valor adotado no projeto (120 l/hab.dia). Com relação aos valores do coeficiente do dia de maior consumo encontrados, (1,15-Glória I e 1,25-Glória II), foi observado uma proximidade do valor de projeto (1,2). Quanto aos valores encontrados para o coeficiente da hora de maior consumo, (2,36-Glória I e 2,41-Glória II), foi verificado que os mesmos encontram-se bem acima dos valores de projeto (1,5). Em se tratando do coeficiente de retorno, o estudo realizado mostrou um valor próximo do valor adotado em projeto (0,81). O resultado dos parâmetros estudados servirá de indicadores para confecção de projetos futuros para populações em condições e características análogas a dos conjuntos estudados.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologia e Recursos Naturais - CTRNpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTALpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Civil.-
dc.subject.cnpqEngenharia Sanitária.-
dc.titleContribuição à aplicação de coeficientes de consumo em projetos de abastecimento de água e esgotamento sanitário em comunidades urbanas de baixa renda do Nordeste do Brasil - estudo de caso.pt_BR
dc.date.issued2007-03-
dc.description.abstractThe aim of this work was to study the per capita consumption rate (q), coefficients of water consumption variation (K1 and K2) and sewage to water ratio (C) for two well-structured places, Gloria I and Gloria II, in Campina Grande city (7°13’11” S, 35°52’31” W), Paraiba state, northeast Brazil, where live 2,304 low-income people transferred from a slum (Favela da Cachoeira).Water for both places was taken from a main pipe of the Campina Grande Water Supply System at a flow-rate of 8.38L/s being 5.13L/s pumped to a 100m3-elevated reservoir for supplying Gloria I and 3.15L/s for feeding straightly Gloria II distribution system. Wastewaters from both places were sewered to a treatment plant made up of the preliminary treatment units bar screen and grit chamber and two stabilization ponds, an anaerobic and a secondary facultative one. Water consumption readings were obtained hourly, between November 2006 and February 2007 for estimating the aimed design parameters on consumption water. Measurements of sewage flow-rate taken hourly, between november 2006 and february 2007, based estimation of sewage to water ratio. The per capita consumption rate of 90L/inhabitant.day was less than that of 120L/inhabitant.day adopted for designing water supply. Estimates for K1 were 1.15 and 1.25, respectively for Gloria I and Gloria II, very close to the design value of 1.2, but the correspondent ones for K2 of 2.36 and 2.41 were higher enough compared to that (1.5), adopted for design. Estimated sewage to water ratio of 0.81 was close to that (0.85) used in the project. Due to the short period of study, coefficients obtained herein will be useful as indicators for designing future systems of water supply and wastewater collection for low-income urban populations in tropical countries.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2854-
dc.date.accessioned2019-02-20T15:37:46Z-
dc.date.available2019-02-20-
dc.date.available2019-02-20T15:37:46Z-
dc.typeDissertaçãopt_BR
dc.subjectConsumo de Água.-
dc.subjectCoeficientes de Variação de Consumo.-
dc.subjectCoeficiente de Retorno.-
dc.subjectWater consumption.-
dc.subjectConsumption Variation Coefficients.-
dc.subjectCoefficient of Return.-
dc.rightsAcesso Abertopt_BR
dc.creatorALMEIDA, Simão Araújo Barbosa de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeContribution to the application of consumption coefficients in water supply and sewage projects in low income urban communities in the Northeast of Brazil - a case study.pt_BR
dc.identifier.citationALMEIDA, Simão Araújo Barbosa de. Contribuição à aplicação de coeficientes de consumo em projetos de abastecimento de água e esgotamento sanitário em comunidades urbanas de baixa renda do Nordeste do Brasil - estudo de caso. 2007. 85 f. Dissertação (Mestrado em Engenharia Civil), Curso de Pós-Graduação em Engenharia Civil, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba, Campina Grande, Paraíba, Brasil, 2007. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2854pt_BR
Appears in Collections:Mestrado em Engenharia Civil e Ambiental.

Files in This Item:
File Description SizeFormat 
SIMÃO ARAÚJO BARBOSA - DISSERTAÇÃO PPGECA 2007.pdfSimão Araújo Barbosa de Almeida - Dissertação PPGECA CTRN 20072.4 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.