Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2901
Full metadata record
DC FieldValueLanguage
dc.creator.IDMEDEIROS FILHO, J. C.pt_BR
dc.contributor.advisor1GUERRA, Hugo Orlando Carllavo.-
dc.contributor.advisor1IDGUERRA, H. O. C.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/5353275464754248pt_BR
dc.contributor.referee1AZEVEDO, Hamilton Medeiros de.-
dc.contributor.referee1IDAZEVEDO, H. M.pt_BR
dc.contributor.referee2NOGUEIRA, Francisco das Chagas.-
dc.contributor.referee2IDNOGUEIRA, F. C.pt_BR
dc.description.resumoUm estudo foi conduzido na Fazenda Experimental "Rafael Fernandes" da Escola Superior de Agricultura de Mossoró (ESAM), Mossoró-RN, no período de outubro de 1981 a fevereiro de 1982, com o objetivo de avaliar o desempenho de um sistema de irrigação por aspersão. Para isso, foi utilizada a metodologia proposta por MERRIAM & KELLER (1978). Os testes foram realizados, sob diferentes condições climáticas, para os espaçamentos entre aspersores ao longo da lateral de 12 e 18m e as alturas do tubo de elevação de 0 , 5 ; 1,0 e 2,0m. Os parâmetros estudados foram a precipitação media, a uniformidade de distribuição de água e as perdas de água por evaporação. Os resultados mostraram que a precipitação média não foi influenciada pela altura do tubo de elevação. As melhores uniformidades de distribuição de água foram obtidas com o tubo de elevação a 2m de altura e com os menores espaçamentos. (-1,2,12 e 12 x 18m). O espaçamento de 18 x 18m apresentou uniformidades satisfatórias. Em geral, a uniformidade de distribuição de água diminuiu com o aumento da velocidade do vento, e o efeito desse fator climático foi mais significativo com o tubo de elevação a 2m de altura. Os fatores climáticos (velocidade do vento, temperatura e umidade relativa do ar) tiveram maior influencia nas perdas de água por evaporação do que a altura do tubo de elevação ou o espaçamento entre aspersores. As perdas aumentaram significativamente com a velocidade do vento. Para as velocidades do vento testadas (2,34 a 6,28 m/s), as perdas de água por evaporação variaram de 6,30 a 19,75%, Para as condições de clima de Mossoró e para as especificações do sistema de aspersão testado, aconselha-se o uso do espaçamento dos aspersores de 18 x 18m e o tubo de elevação a uma altura de 2m, com as irrigações sendo preferencialmente conduzidas no período da manhã.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologia e Recursos Naturais - CTRNpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTALpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Civil-
dc.titleAvaliação de um sistema de irrigação por aspersão em uma área do município de Mossoró-RN.pt_BR
dc.date.issued1983-05-
dc.description.abstractA study was conducted at the "Rafael Fernandes" Experimental Farm of the "Escola Superior de Agricultura de Mossoró", at Mossoró,RN, Brazil, with the objective to evaluate the performance of a sprinkler írrigation system. The methodology used was that proposed by Merriam and Keller (1978), The tests were carried out under different climatic conditions using 12 and 18m spacing between sprinklers along the lateral and risers heights of 0 . 5 ; 1.0 and 2,0m. The parameters studied were the average precipitation, water distribution uniformity, and water losses by evaporation. The results showed that the average precipitation was not affected by the riser height. The best water uniformity distribution were obtained with the riser at 2m high and with the smallest spacings (12 x 12 and 12 x 18m). The 18 x 18m spacing presented satisfactory water distribution uniformity. In general, the water distribution uniformity decreased with increasing windspeed and the effect of this climatic factor was more pronounced with the riser at 2m high. The climatic factors (windspeed, temperature and air relative humidity) had greater effect on the water losses by evaporation than the riser height or spacing between sprinklers. The losses increased significantly with increasing windspeed. The tested speeds (2.34 to 6.28 m/s) caused water losses by evaporation that ranged from 6,30 to 19.75%, Under the climatic conditions of Mossoró city and considering the specifications of the tested sprinkler írrigation system, it is advised the use of the sprinkler spacing of 18x18m and the riser height of 2m, with the irrigations being conducted preferably at morning.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2901-
dc.date.accessioned2019-02-22T15:52:09Z-
dc.date.available2019-02-22-
dc.date.available2019-02-22T15:52:09Z-
dc.typeTesept_BR
dc.subjectIrrigação por aspersão-
dc.subjectSprinkler Irrigation-
dc.subjectSistema de irrigação-
dc.subjectIrrigation system-
dc.subjectAvaliação de sistema-
dc.subjectSystem Evaluation-
dc.rightsAcesso Abertopt_BR
dc.creatorMEDEIROS FILHO, José Cipriano de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeEvaluation of a sprinkler irrigation system in an area of the municipality of Mossoró-RN.pt_BR
dc.identifier.citationMEDEIROS FILHO, José Cipriano de. Avaliação de um sistema de irrigação por asoersão em uma área do município de Mossoró-RN. 1983. 92f. (Dissertação de Mestrado em Engenharia Civil), Curso de Pós-Graduação em Engenharia Civil, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba – Campus II - Campina Grande - PB - Brasil, 1983. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2901pt_BR
Appears in Collections:Mestrado em Engenharia Civil e Ambiental.

Files in This Item:
File Description SizeFormat 
JOSÉ CIPRIANO DE MEDEIROS FILHO - DISSERTAÇÃO PPGECA 1983.pdfJosé Cipriano de Medeiros Filho - Dissertação PPGECA 19832.47 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.