Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3011
Full metadata record
DC FieldValueLanguage
dc.creator.IDOLIVEIRA, A. R.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/6114358397430196pt_BR
dc.contributor.advisor1FRANÇA, Kepler Borges.-
dc.contributor.advisor1IDFRANÇA, K. B.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3620576114544758pt_BR
dc.contributor.advisor2LABORDE, Hervé Michel.-
dc.contributor.advisor2IDLABORDE, H. M.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/4586255595693837pt_BR
dc.contributor.referee1FOSSY, Michel François.-
dc.contributor.referee1IDFOSSY, M. F.pt_BR
dc.contributor.referee2LUCIANO, Benedito Antonio.-
dc.contributor.referee2IDLUCIANO, B. A.pt_BR
dc.contributor.referee3OLIVEIRA, Leimar de.-
dc.contributor.referee3IDOLIVEIRA, L.pt_BR
dc.description.resumo0 presente trabalho visa estudar o desempenho de um sistema de dessalinização via osmose inversa, em escala piloto, fazendo uso de painéis fotovoltaicos,'o qual foi desenvolvido no Laboratório Referência em Dessalinização do Departamento de Engenharia Química da Universidade Federal de Campina Grande. O desempenho do sistema foi avaliado sob as seguintes águas: soluções de cloreto de sódio de concentração de 1000 mg/L a 4000 mg/L e águas salobras de poços tubulares com concentração de 2000 mg/L para uma faixa de pressão de 4,0 kgf/cm2 a 12 kgf/cm2 . A partir das variáveis de medidas como: tensão, corrente elétrica, vazão, condutividade elétrica e pH, foram avaliados os seguintes parâmetros: potência elétrica, vazão do permeado e do concentrado, recuperação e consumo de energia. A faixa de menor consumo de energia de 1,42 kWh/m3 a 2,3 kWh/m3 foi obtida sob a pressão de 10,0 kgf/cm2 para as soluções estudadas. O sistema mostrou condições técnicas de produzir 0,2 m3 /h de água dessalinizada a um custo viável de US$ 1,13/m3.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Ciências e Tecnologia - CCTpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA QUÍMICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia química-
dc.titleDesempenho de um sistema de dessalinização via osmose inversa, em escala piloto, alimentado por painéis fotovoltaicos.pt_BR
dc.date.issued2002-10-
dc.description.abstractIn this work the performance of small-scaled reverse osmosis desaíination unit is studied using photovoltaic solar energy. This unit was developed in the Reference Laboratory of Desaíination of the Chemical Engineering Department of the Federal University of Campina Grande. The system was tested with several sodium chloride solutions from 1000 mg/L to 4000 mg/L and brackish water from welis at concentration of 2000 mg/L under pressures from 4 kgf/cm2 to 12 kgf/cm2 The measurement of voltage, electric current, permeate and concentrate flows, electric conductinty and pH ailowed to evaiue the performance of the following parameters; electric power, recovery and energy consumption. The lowest range of energy consumption, was obtained at 10 kgf/cm2 , which was 1.42 kWh/m3 to 2.3 kWh/m3. The system provided technical conditions to produce 0.2 m3 /h of dessalinated at reasonable cost of US$ 1.13/ m3.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3011-
dc.date.accessioned2019-03-01T17:13:09Z-
dc.date.available2019-03-01-
dc.date.available2019-03-01T17:13:09Z-
dc.typeDissertaçãopt_BR
dc.subjectDessalinização-
dc.subjectDesalinización-
dc.subjectOsmose inversa-
dc.subjectÓsmosis inversa-
dc.subjectReverse osmosis-
dc.subjectDesalination-
dc.subjectFotovoltaico-
dc.subjectPhotovoltaic-
dc.subjectFotovoltaica-
dc.subjectEscala piloto-
dc.subjectPilot Scale-
dc.subjectIncrustação-
dc.subjectFouling-
dc.subjectEnsuciamiento-
dc.rightsAcesso Abertopt_BR
dc.creatorOLIVEIRA, Arleide Ricarte de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativePerformance of a reverse osmosis desalination system, on a pilot scale, powered by photovoltaic panels.pt_BR
dc.identifier.citationOLIVEIRA, Arleide Ricarte de. Desempenho de um sistema de dessalinização via osmose inversa, em escala piloto, alimentado por painéis fotovoltaicos. 2002. 111f. (Dissertação de Mestrado em Engenharia Química), Programa de Pós-graduação em Engenharia Química, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande - Paraíba - Brasil, 2002. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3011pt_BR
Appears in Collections:Mestrado em Engenharia Química

Files in This Item:
File Description SizeFormat 
ARLEIDE RICARTE DE OLIVEIRA - DISSERTAÇÃO PPGEQ CCT 2002.pdfArleide Ricarte de Oliveira - Dissertação PPGEQ 20022.73 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.