Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3034
Title: Automação de um sistema de tratamento de esgotos baseado no processo de lodo ativado.
Other Titles: Automation of a sewage treatment system based on the activated sludge process.
???metadata.dc.creator???: LIRA, Valnyr Vasconcelos.
???metadata.dc.contributor.advisor1???: BARROS, Péricles Rezende
???metadata.dc.contributor.advisor2???: ROCHA NETO, José Sérgio da.
???metadata.dc.contributor.referee1???: LIMA, Antonio Marcus Nogueira.
???metadata.dc.contributor.referee2???: FREIRE, Raimundo Carlos Silvério.
Keywords: Automação;Automatización;Automation;Tratamento de esgoto;Sewage treatment;Tratamiento de aguas residuales;Lodo aditivado;Lodos aditivos;Additive sludge;Águas residuárias;Wastewater;Aguas residuales
Issue Date: Jul-2001
Publisher: Universidade Federal de Campina Grande
Citation: LIRA, Valnyr Vasconcelos. Automação de um sistema de tratamento de esgotos baseado no processo de lodo ativado. 2001. 115f. (Dissertação de Mestrado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2001.
???metadata.dc.description.resumo???: Nesta dissertação é apresentado uni sistema de tratamento de esgotos consistindo de um processo anaeróbio, realizado por um reator UAS13, em serie com um processo aeróbio, implementado por um rcator de bateladas sequenciais. O reator UASB foi escolhido como processo anaeróbio por ser um sistema de grande potencial para regiões de clima quente, como é o caso da região Nordeste. .Já o reator de bateladas sequenciais foi utilizado como processo aeróbio por ser a versão mais simples dos sistemas baseados no processo de lodo ativado. A utilização de um sistema híbrido, isto é, anaeróbio aeróbio, visa a redução dos custos de construção c operação da planta de tratamento. Neste caso, grande parte do material orgânico do esgoto é retirado no processo anaeróbio, e assim, os tanques de aeração c a quantidade de oxigénio necessária para a etapa aeróbia são menores. A automação deste sistema de tratamento foi implementada. Como o processo anaeróbio não utiliza equipamentos elétricos nem mecânicos, a automação rcstringiu-se apenas ao processo aeróbio, isto é, aos reatores de bateladas sequenciais. É possível operar o sistema automaticamente, ou remotamente através de um computador via um sistema supervisório. Além das automação, uma nova técnica para determinação do fim do período de aeração foi apresentada nesta dissertação. Esta técnica, diferentemente das técnicas clássicas, não necessita da estimação de parâmetros como a taxa de respiração ou a função de transferência de oxigénio. Neste caso, o valor médio da concentração de oxigénio dissolvido no reator indica quando a aeração deve ser interrompida. Assim, com esta técnica, o sistema é capaz de tratar um maior volume de esgoto por dia, além de economizar energia.
Abstract: In this dissertation, a wastewater treatriient system is presented. K. consists of an anaerobic process, accomplished by an UASB reactor, in series with an aerobic process, iiiiplemeiited by asequencing batcli reactor. The UASB reactor was cliosen as the anaerobic process because it's a system of great potenfial for áreas of hot cliniafe, as the Northeast arca. The sequencing batcli reactor was used as aerobic process since it is the simplest version of the activated sludgc systeins. The use of a lrybrid system, that is, an anaerobicaerobic one, seeks the reduction of the construction and operation costs of the treatment plant. In this case, great part of the wastewater organic material is removed in the anaerobic process, so that, the aeration tanks and the amount of oxygen needed for the aerobic stage are smaller. The automation of this treatment system was iniplemented. As the anaerobic process doesn't use electric nor mechanical equipments, the automation isjust limited to the aerobic process, that is, to the sequencing batch reactors. It is possible to operate the system automatically, or remotely through a computer running a supervisory system. Besides the automation, a new technique for determing the end of the aeration period was presented in this dissertation. This technique, difFerently from the classic techniques, has no need to estimate parameters as the respiration rate or the oxygen transfer function. In this case, the average value of the oxygen dissolved concentration in the reactor indicates when the aeration should be interrupted. Then, with this technique, the system is capable to treat a larger wastewater volume by day, besides saving energy.
Keywords: Automação
Automatización
Automation
Tratamento de esgoto
Sewage treatment
Tratamiento de aguas residuales
Lodo aditivado
Lodos aditivos
Additive sludge
Águas residuárias
Wastewater
Aguas residuales
???metadata.dc.subject.cnpq???: ENGENHARIA ELÉTRICA
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3034
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
VALNYR VASCONCELOS LIRA - DISSERTAÇÃO PPGEE 2001.pdfValnyr Vasconcelos Lira - Dissertação PPGEE 200123.17 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.