dc.description.resumoINTRODUÇÂO: A fototerapia tem sido a conduta universalmente mais difundida para o tratamento da icterícia neonatal. O correto manejo, bem como aparelhos e lâmpadas adequadas com contínuo monitoramento de suas irradiâncias, são de fundamental importância para que a fototerapia seja eficaz no tratamento da doença, reduzindo o tempo de internamento e o risco de dano cerebral. OBJETIVO: Avaliar a eficácia dos aparelhos de fototerapia utilizados em recém-nascidos no Instituto Cândida Vargas (ICV) através da medição padronizada da irradiância. METODOLOGIA: Trata-se de um estudo transversal com caráter descritivo e abordagem quantitativa. A amostra foi composta por todos os aparelhos de fototerapia disponíveis no serviço, totalizando 17. Para aferição foi utilizado um fotodosímetro modelo THOR Multitester 3620, calibrado diretamente em microwatts por centímetros ao quadrado por nanômetros (μw/cm2/nm). Os dados foram tabulados em planilha Excel e analisados descritivamente. RESULTADO: Foram analisados 17 aparelhos de fototerapia, sendo 16 Bilispot® e 1 Biliberço®. A irradiância média dos aparelhos foi de 2,95 μW/cm²/nm ± 1,42. Os aparelhos do tipo Bilispot® apresentaram uma variação de 0,97 a 5,32 μW/cm²/nm, média de 2,77 μW/cm²/nm; o Biliberço® apresentou a maior irradiância entre todos os aparelhos analisados, com um valor de 5,87 μW/cm²/nm. Apenas 17,64% dos aparelhos apresentaram uma irradiância maior que 4 μW/cm²/nm. CONCLUSÃO: A maioria dos aparelhos estavam com irradiância inferior ao mínimo considerado terapêutico, tornando evidente a necessidade de uma maior eficácia na manutenção dos aparelhos de fototerapia.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Ciências Biológicas e da Saúde - CCBSpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqMedicina.pt_BR
dc.titleIrradiância dos aparelhos de fototerapia em uma maternidade de João Pessoa.pt_BR
dc.date.issued2018-08-01-
dc.description.abstractINTRODUCTION: Phototherapy has been universally most widely used way to treat neonatal jaundice, and the correct management, as well as adequate devices and lamps with continuous monitoring of their irradiances, are of fundamental importance for effective phototherapy in the treatment of jaundice, reducing the length of hospitalization and the risk of brain damage. OBJECTIVE: Evaluate the effectiveness of phototherapy devices used in newborns at Instituto Cândida Vargas (ICV) through the standardized measurement of the irradiance. STUDY DESIGN: This is a descriptive cross-sectional study with a quantitative approach. To measure the 17 phototherapy devices, a THOR Multitester 3620 photodosimeter was used, calibrated directly in microwatts per square centimeters per nanometer (mw / cm2 / nm). RESULTS: 17 phototherapy devices, 16 Bilispot® and 1 Biliberço®, were analyzed. The mean irradiance of the devices was 2.95 μW/cm²/nm ± 1.42. The Bilispot®-type devices presented a variation of 0.97 to 5.32 μW/cm²/nm, average of 2.77 μW/cm²/nm; Biliberço® presented the highest irradiance among all analyzed devices, with a value of 5.87 μW/cm²/nm. Only 17.64% of the devices had an irradiance greater than 4 μW/cm²/nm. CONCLUSION: The majority of the devices had irradiance below the minimum considered therapeutic, making evident the need for a greater efficiency in the maintenance of phototherapy devices.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/30625-
dc.date.accessioned2023-07-09T20:37:01Z-
dc.date.available2023-07-09-
dc.date.available2023-07-09T20:37:01Z-
dc.typeTrabalho de Conclusão de Cursopt_BR
dc.subjectIcteríciapt_BR
dc.subjectFototerapiapt_BR
dc.subjectIcterícia neonatalpt_BR
dc.subjectJaundicept_BR
dc.subjectPhototherapypt_BR
dc.subjectNeonatal jaundicept_BR
dc.subjectEstudo transversal com caráter descritivo e abordagem quantitativapt_BR
dc.subjectIrradiância - equipamentos hospitalares - maternidadept_BR
dc.subjectMaternidade - João Pessoa - PBpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorALVES, Lívia Feitosa.-
dc.creatorCATUNDA, Stephanie Bento.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeIrradiance of phototherapy devices in a maternity hospital in João Pessoa.pt_BR
dc.identifier.citationALVES, Lívia Feitosa. CATUNDA, Stephanie Bento. Irradiância dos aparelhos de fototerapia em uma maternidade de João Pessoa. 2018. 35fl. (Trabalho de Conclusão de Curso – Monografia), Curso de Bacharelado em Medicina, Centro de Ciências Biológicas e da Saúde, Universidade Federal de Campina Grande – Paraíba – Brasil, 2018.pt_BR