Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/30946
Full metadata record
DC FieldValueLanguage
dc.creator.IDCARDOSO, I. S.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/0482898604136573pt_BR
dc.contributor.advisor1COSTA, Edson Guedes da.-
dc.contributor.advisor1IDCOSTA, E. G.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3930289115658143pt_BR
dc.contributor.advisor2ARAÚJO, Jalberth Fernandes de.-
dc.contributor.advisor2IDARAÚJO, J. F.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/6903049112797651pt_BR
dc.contributor.referee1SOUZA, Benemar Alencar de.-
dc.contributor.referee1IDSOUZA, B. A.pt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/4987294390789975pt_BR
dc.contributor.referee2DANTAS, Karcius Marcelus Colaço.-
dc.contributor.referee2IDDANTAS, K. M. C.pt_BR
dc.contributor.referee2Latteshttp://lattes.cnpq.br/1881990103809201pt_BR
dc.contributor.referee3NOBREGA, Luiz Augusto Medeiros Martins.-
dc.contributor.referee3IDNOBREGA, L. A. M. M.pt_BR
dc.contributor.referee3Latteshttp://lattes.cnpq.br/6667507308429720pt_BR
dc.description.resumoNeste trabalho é proposta uma metodologia para regulação de tensão no ponto de acoplamento comum de uma rede de distribuição secundária após inserção de geração distribuída fotovoltaica. A rede de distribuição foi analisada a partir de simulações computacionais tomando como base os dados de uma rede de distribuição real localizada no estado da Paraíba, Brasil. As simulações computacionais foram realizadas com o objetivo de analisar se a inserção de geração distribuída fotovoltaica provoca violações dos limites de tensão determinados como adequados pela Agência Nacional de Energia Elétrica brasileira; analisar se a variação da posição do TAP do transformador de distribuição é uma forma de regular a tensão no PAC; analisar se a variação das estações do ano impacta no número de violações dos valores de tensão no PAC. A partir das simulações, verificou-se que, antes da aplicação da metodologia, ao longo de todo o ano ocorreram 142 violações do limite máximo de tensão considerado adequado, além disso também foi concluído que a variação do TAP do transformador aumentou a quantidade de violações do limite de tensão e que as estações do ano impactam diretamente na quantidade de violações, bem como no valor das tensões registradas no PAC. Após a aplicação da metodologia, redistribuindo 27 cargas na fase da unidade geradora, a tensão não ultrapassou nenhuma vez o limite máximo exigido. Com a regulação de tensão obtida a partir da metodologia deste trabalho, pode-se garantir uma maior segurança aos consumidores e aos equipamentos instalados na rede de distribuição na qual a unidade geradora está instalada, redução de custos para a concessionária de energia, além de ser uma possível solução para um dos maiores problemas da inserção da unidade de geração distribuída na rede de distribuiçãopt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.pt_BR
dc.titleMetodologia de regulação de tensão no PAC de uma rede de distribuição secundária após a inserção de geração distribuída fotovoltaica.pt_BR
dc.date.issued2022-04-01-
dc.description.abstractIn this papper it is proposes a methodology for voltage regulation at the common control point of a secondary distribution network after insertion of photovoltaic distributed generation. The distribution network in Brazil was based on computer simulations based on data from a real distribution network located in the state of Paraíba. As simulations carried out with the objective of studying whether a distributed distribution insertion causes restrictions on the limits of equipment equipment such as equipment by the Brazilian National Electric Energy Agency; if the position of the distribution transformer TAP is a way of analyzing the regulation of the voltage in the PAC; analyze whether the seasons of the seasons impact the number of Violations of test values in the PAC. From all the simulations, it was also observed that, before the application of the methodology of the entire resource process, it was also performed, that the TAP transformation process was also carried out from an alternative resource, the from a process of transformation of the entire process, which can be carried out from the voltage limit and that the seasons directly impact the ownership of recorded Violations, as well as the value of minor Violations in the PAC. After applying the methodology, redistributing 27 loads in the generator unit phase, the voltage never exceeded the maximum possible limit. From a study regulation carried out from the methodology of this work, it is possible to guarantee greater safety to users and to the equipment installed in the distribution network in which the generating unit is installed, cost reduction for the provision of safety services , in addition to being a possible solution to one of the biggest problems of inserting the distributed generation unit in the distribution networkpt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/30946-
dc.date.accessioned2023-07-20T12:12:32Z-
dc.date.available2023-07-20-
dc.date.available2023-07-20T12:12:32Z-
dc.typeDissertaçãopt_BR
dc.subjectRedistribuição de cargaspt_BR
dc.subjectRede de distribuiçãopt_BR
dc.subjectGeração distribuída fotovoltaicapt_BR
dc.subjectViolação dos limites de tensãopt_BR
dc.subjectPonto de acoplamento comumpt_BR
dc.subjectRede de distribuição secundáriapt_BR
dc.subjectUnidade de geração distribuídapt_BR
dc.subjectLoad redistributionpt_BR
dc.subjectDistribution networkpt_BR
dc.subjectPhotovoltaic distributed generationpt_BR
dc.subjectViolation of voltage limitspt_BR
dc.subjectCommon docking pointpt_BR
dc.subjectSecondary distribution networkpt_BR
dc.subjectDistributed generation unitpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorCARDOSO, Izadora Soares.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeVoltage regulation methodology in the PAC of a power supply network secondary distribution after the insertion of distributed generation photovoltaic.pt_BR
dc.identifier.citationCARDOSO, I. S. Metodologia de regulação de tensão no PAC de uma rede de distribuição secundária após a inserção de geração distribuída fotovoltaica. 2022. 71 f. Dissertação (Mestrado em Engenharia Elétrica) — Universidade Federal de Campina Grande, Centro de Engenharia Elétrica e Informática, Campina Grande, Paraíba, Brasil, 2023.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
IZADORA SOARES CARDOSO - DISSERTAÇÃO (PPGEE) 2022 (4).pdfIZADORA SOARES CARDOSO - DISSERTAÇÃO (PPGEE) 2022 (4)41.23 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.