Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3231
Full metadata record
DC FieldValueLanguage
dc.creator.IDARAÚJO, G. A. L.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/8261564685433904pt_BR
dc.contributor.advisor1FREIRE, Raimundo Carlos Silvério.-
dc.contributor.advisor1IDFREIRE, R. C. S.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4016576596215504pt_BR
dc.contributor.advisor2CATUNDA, Sebastian Yuri Cavalcanti.-
dc.contributor.advisor2IDCATUNDA, S. Y. C.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/0873496251879638pt_BR
dc.contributor.referee1DÓI, Ioshiaki.-
dc.contributor.referee2BARROS, Allan Kardec Dualibe.-
dc.contributor.referee3SILVA, João Bosco de Aquino.-
dc.contributor.referee4LUCIANO, Benedito Antonio.-
dc.description.resumoA técnica de oscilações forçadas é um método não invasivo de avaliação da mecânica pulmonar. Ela é usada para determinar a impedância do sistema respiratório que é calculada a partir de sinais de pressão e fluxo medidos próximos à boca do paciente. No sistema convencional estes sinais são induzidos a partir de sinais senoidais de pressão impostos por meio de um alto-falante e o transdutor de fluxo é um pneumotacômetro. Este equipamento mede a diferença de pressão entre dois pontos de um tubo que tem uma resistência mecânica interna, constituída de vários tubos capilares sobrepostos ou finas malhas metálicas. A tendência é que o pneumotacômetro seja bloqueado por saliva e condensação durante um uso prolongado, devido às partículas expelidas pelo paciente no processo respiratório. Isto aumenta a resistência efetiva do sensor de fluxo e conduz a erros. Visando encontrar métodos alternativos para a medição de fluxo respiratório com a técnica de oscilações forçadas, são utilizados outros tipos de sensores, tais como sensores termo-resistivos de fio de platina e sensores ultra-sônicos. São mostrados resultados experimentais da medição do fluxo respiratório com esses sensores e comparados com os obtidos com um pneumotacômetro.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.-
dc.titleSensores termo-resistivos e ultrassônicos na medição de fluxo respiratório com a técnica de oscilações forçadas.pt_BR
dc.date.issued2007-05-
dc.description.abstractThe forced oscillations technique is a non invasive method to investigate lung mechanics. It is used to determine the impedance of the respiratory system that is derived from the pressure and flow signals recorded at the mouth of the patient. In the conventional setup these signals are induced starting from sinusoidal pressure signals imposed by means of a loudspeaker, and the flow transducer is a pneumotachometer. This equipment measures the pressure difference between two points on a tube with an inner mechanical resistance element consisting of a bundle of capillary tubes or a wire mash screen. The pneumotachometer tendency is to become clogged with mucous and condensations during prolonged use, due to the particles expelled by the patient in the respiratory process. This increases the effective resistance of the flow head and leads to errors. In order to find alternative methods for the measurement of the respiratory flow with the forced oscillations technique, other kinds of sensor are used, such as platinum wire termoresistive sensors and ultrasonic sensors. Experimental results of the respiratory flow measured with these sensors are showed and compared with the results obtained by a pneumotachometer.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3231-
dc.date.accessioned2019-03-25T17:11:38Z-
dc.date.available2019-03-25-
dc.date.available2019-03-25T17:11:38Z-
dc.typeTesept_BR
dc.subjectMedição de Fluxo Respiratório-
dc.subjectAnemómetro a Fio Aquecido-
dc.subjectAnemómetro Ultrassônico-
dc.subjectTécnica de Oscilações Forçadas-
dc.subjectMeasurement of Respiratory Flow-
dc.subjectHeated Wire Anemometer-
dc.subjectUltrasonic Anemometer-
dc.subjectTechnique of Forced Oscillations-
dc.rightsAcesso Abertopt_BR
dc.creatorARAÚJO, Guilherme Augusto Limeira.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeThermo-resistive and ultrasonic sensors in the measurement of respiratory flow with the technique of forced oscillations.pt_BR
dc.identifier.citationARAÚJO, Guilherme Augusto Lima. Sensores termo-resistivos e ultrassônicos na medição de fluxo respiratório com a técnica de oscilações forçadas. 2007. 113 f. Tese (Doutorado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2007.pt_BR
Appears in Collections:Doutorado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
GUILHERME AUGUSTO LIMA ARAÚJO - TESE PPGEE 2007.pdfGuilherme Augusto Lima Araújo- Tese de Doutorado PPGEE 20071.22 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.