dc.description.resumoUm novo método para religamento controlado de linhas de transmissão com compensação reativa em derivação é proposto nesta tese. Este método baseia-se em técnicas simples para tratamento dos sinais de tensão necessários para o controle das manobras, consistindo na aplicação de transformações modais para separar as componentes de frequência contidas nos sinais sob análise. Como consequência de sua aplicação, obtém-se surtos de manobras de menor amplitude. Além disto, o método é capaz de detectar a extinção de defeitos fase-terra e fase- terra, os quais correspondem a mais de 80% dos defeitos nas linhas de 500 e 750 kV do SIN (Sistema Interligado Nacional). Ao se empregar a abordagem proposta, evita-se que o religamento ocorra sob defeito. Após identificar a extinção deste, é possível religar a linha e minimizar o tempo morto em que esta fica fora de operação. Assim, reduz-se o tempo de recomposição do sistema, aumentando a sua contabilidade e disponibilidade. Como aplicação desta metodologia, um dispositivo para controle de manobras de religamento de linhas de transmissão foi implementado e avaliado em um simulador digital de sistemas elétricos em tempo real, o RTDSTM (Real Time Digital Simulator ). Adicionalmente, uma versão o ine do método foi implementada para análises paramétricas e de sensibilidade por meio de registros oscilográficos reais e simulações digitais via EMTP (Electromagnetic Transients Program). Dados do SIN foram utilizados para estudo de casos e os resultados obtidos comprovam a eficiência do método em identificar a extinção de defeitos bem como em reduzir os surtos de manobras, independente dos parâmetros avaliados, a exemplo do grau de compensação da linha, da resistência de defeito e do local de sua ocorrência.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.
dc.titleChaveamento controlado aplicado ao religamento rápido de linhas de transmissão.pt_BR
dc.date.issued2012-04-13
dc.description.abstractA new method for controlled reclosing of transmission lines with shunt reactive compensation is proposed in this thesis. The method is based on simple techniques for analysis of voltage signals required to control the switching operations. It consists in applying modal transformations for separating the frequency components contained in the signals being analyzed. As a result of its application, smaller switchings surges are obtained. Moreover, the method determines the extinction time of single and double-phase to ground faults, which account for more than 80% of faults in 500 and 750 kV transmission lines at the Brazilian Power System Grid. By using the proposed approach, it is possible to prevent reclosing onto fault. After identifying the fault extinction time, it is possible to reclose the line and minimize the dead time in which it is out of service. This reduces the power system restoration time, increasing its reliability and availability. As an application of this methodology, a device to control the line reclosing was implemented and evaluated in a Real Time Digital Simulator (RTDSTM). In addition, an o ine version of the method was implemented for parametric and sensitivity analyzes by means of actual oscillographic data and digital simulations using EMTP (Electromagnetic Transients Program). Data from the Brazilian Power System Grid were used to produce some case studies and the results attest the e ciency of the method to identify the fault extinction time as well as to mitigate the switchings surges, regardless of the parameters evaluated, such as the degree of line compensation, fault resistance and fault location.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3265
dc.date.accessioned2019-03-27T15:11:12Z
dc.date.available2019-03-27
dc.date.available2019-03-27T15:11:12Z
dc.typeTesept_BR
dc.subjectChaveamento Controlado.
dc.subjectExtinção de Defeitos.
dc.subjectLinhas de Transmissão.
dc.subjectSobretensões de Manobra.
dc.subjectControlled Switching.
dc.subjectDefect Extinction.
dc.subjectTransmission lines.
dc.subjectManeuver overvoltages.
dc.rightsAcesso Abertopt_BR
dc.creatorDANTAS, Karcius Marcelus Colaço.
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeControlled switching applied to fast reclosing of transmission lines.pt_BR
dc.identifier.citationDANTAS, Karcius Marcelus Colaço. Chaveamento controlado aplicado ao religamento rápido de linhas de transmissão. 2012. 177f. (Tese de Doutorado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2012.pt_BR