Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3479
Title: Avaliação das condições de conforto ambiental em um hospital público regional de urgência e emergência.
Other Titles: Evaluation of environmental comfort conditions in a regional public emergency and emergency hospital.
???metadata.dc.creator???: PEREIRA, Cayo Farias.
???metadata.dc.contributor.advisor1???: MEIRA, Celeide Maria Belmont Sabino.
???metadata.dc.contributor.referee1???: COURA, Mônica de Amorim.
???metadata.dc.contributor.referee2???: ARAÚJO, André Luís Calado.
Keywords: Conforto Ambiental;Hospital - Engenharia Civil;Ambiente Construído;Environmental comfort;Hospital - Civil Engineering;Built Environment;Hospital;Conforto ambiental;Environmental comfort;Confort ambiental;Ambiente construído;Built environment;Entorno construido;Acústica hospitalar;Acústica hospitalaria;Hospital acoustics
Issue Date: Feb-2014
Publisher: Universidade Federal de Campina Grande
Citation: PEREIRA, Cayo Farias. Avaliação das condições de conforto ambiental em um hospital público regional de urgência e emergência. 2014. 98 f. Dissertação (Mestrado em Engenharia Civil e Ambiental), Programa de Pós-Graduação em Engenharia Civil e Ambiental, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande, Campina Grande, Paraíba, Brasil, 2014. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3479
???metadata.dc.description.resumo???: Esta avaliação possibilitou o aprofundamento do conhecimento sobre as condições de conforto ambiental em ambientes hospitalares, uma vez que a bibliografia referente a este assunto é limitada. A pesquisa foi realizada entre os meses de março a dezembro de 2013 no hospital, foram utilizadas recomendações das normas NBR 5413/1992 e NBR 10152/1987, e do projeto executivo elaborado pela SUPLAN para as condições de conforto térmico. A seleção dos 49 pontos de amostragem compreendeu todos os setores desde o pronto atendimento até a lavanderia. As análises foram realizadas com o auxílio dos equipamentos: decibelímetro e dosímetro de ruído para o conforto acústico, termômetro de globo para o conforto térmico e luxímetro digital para o conforto luminoso. As trinta aferições realizadas foram divididas em vinte durante o período diurno e as demais no período noturno. Os resultados obtidos foram divididos nos três indicadores estudados. Para o conforto luminoso foram registradas conformidades e não conformidades com a norma NBR 10152/1987, destacando-se a lavanderia (setor P6) que obteve maior conformidade durante o dia, já no período noturno houve 91,83% de não conformidade em todo o hospital. O conforto acústico apresentou conformidades, durante o período diurno, apenas no ponto P3 (entrada da UTI pediátrica) de 5%, 20% na armazenagem e 5% no final do corredor da enfermagem cirúrgica geral. No período noturno esperava-se que as reduções dos níveis de ruído, provenientes da redução do fluxo de pessoas e de equipamentos ligados a rede elétrica, haveria a conformidade do indicador. O conforto térmico, durante o dia, foi detectado em apenas três pontos: pronto atendimento, enfermaria de queimados e enfermaria clínica. Já no período noturno a frequência de conformidade aumentou atingindo valores de até 90% no ponto P1, 60% nos pontos P2 e P3, de 90% a 100% nas enfermarias P7, P8, P9, P11, P14 e P16. Considerando o conforto ambiental pode-se concluir que não há conforto nas instalações do hospital devido as inúmeras não conformidades nos seus setores. Recomenda-se a adequação dos setores do hospital com a instalação de luminárias, lâmpadas e remoção de películas das janelas para melhorar níveis de iluminamento dos ambientes; criação e implantação de do programa preventivo e educativo voltado para a saúde e redução do ruído em todos os ambientes; e criação de um sistema de ventilação para os ambientes e desbloqueio das janelas existentes. A união dos três indicadores resulta em ambientes desconfortáveis para pacientes, acompanhantes e funcionários; sendo necessários estudo, pós adequação as normas, visando a redução do desconforto ambiental e melhoria da qualidade de vida de toda a população envolvida.
Abstract: This assessment led to the deepening of knowledge about environmental comfort conditions in hospital environments, once the bibliography concerning this matter is limited. The survey was conducted between the months of march to December of 2013 at the hospital were used standards recommendations of NBR 5413/1992 and NBR 10152/1987, the executive project prepared by SUPLAN for conditions of thermal comfort. The selection of sampling points comprised all 49 sectors from the emergency room to the laundry. The analyses were carried out with the aid of equipment: decibel meter and dosimeter for acoustic comfort noise, globe thermometer to the thermal comfort and digital luxímetro for lighting comfort. The thirty measurements performed were divided into two bouts: during the daytime and the other at night. The results were organized and divided in three indicators studied. For the comfort of light were recorded compliance and nonconformities with the NBR 10152/1987, especially the laundry (P6) that obtained grater compliance during the day, at night there was 91,83% of noncompliance throughout the hospital. Acoustic comfort presented compliance, during the daytime period, just at the point P3 (entrance to the Pediatric UTI) of 5%, 20% on storage and 5% at the end of the corridor of the general surgical nursing. At night it was hoped that the reductions in noise levels from the reduction in the flow of people and equipment connected to power grid, there would be compliance of the indicator. The thermal comfort, during the day, was detected in only three points: emergency care, ward burned and medical ward. Already at night the frequency of compliance increased reaching values up to 90% in point P1, 60% in P2 and P3 points of 90% to 100% in wards P7, P8, P9, P11, P14 and P16. Considering the environmental comfort we can conclude that there’s no comfort in the premises of the hospital because of the numerous non-conformities in their sectors. It is recommended that the adequacy of the sectors of the hospital with the installation of luminaires, lamps and window films removal to improve levels of illuminance of environments. Creation and implementation of preventive and educational program geared toward health and reduction of noise in all environments. And the final is creation of a ventilation system for the existing windows environments and unlock. The union of the three indicators results in uncomfortable environments for patients, caregivers and staff, study are needed aiming at the reduction of environmental discomfort and improve the quality of life of all people involved.
Keywords: Conforto Ambiental
Hospital - Engenharia Civil
Ambiente Construído
Environmental comfort
Hospital - Civil Engineering
Built Environment
Hospital
Conforto ambiental
Environmental comfort
Confort ambiental
Ambiente construído
Built environment
Entorno construido
Acústica hospitalar
Acústica hospitalaria
Hospital acoustics
???metadata.dc.subject.cnpq???: Engenharia Civil.
Engenharia Sanitária.
Engenharia civil
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3479
Appears in Collections:Mestrado em Engenharia Civil e Ambiental.

Files in This Item:
File Description SizeFormat 
CAYO FARIAS PEREIRA - DISSERTAÇÃO PPGECA 2014.pdfCayo Farias Pereira - Dissertação PPGECA 20142.65 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.