Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/34969
Title: Dimensionamento de cortina atirantada.
Other Titles: Sizing of chain-link curtains.
???metadata.dc.creator???: ARRUDA, Lucas Wesley de Souza.
???metadata.dc.contributor.advisor1???: SOUZA, Leovegildo Douglas Pereira de.
???metadata.dc.contributor.referee1???: MEDEIROS, Eduardo Morais de.
???metadata.dc.contributor.referee2???: GOMES, Rafaela Nascimento.
Keywords: Estrutura de contenção;Containment structure;Tirantes;Tie Rods;Estabilidade de talude;Slope stability
Issue Date: 4-Dec-2023
Publisher: Universidade Federal de Campina Grande
Citation: ARRUDA, Lucas Wesley de Souza. Dimensionamento de cortina atirantada. 2023. 64 f. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Civil) - Centro de Ciências e Tecnologia Agroalimentar, Universidade Federal de Campina Grande, Pombal, Paraíba, Brasil, 2023.
???metadata.dc.description.resumo???: As estruturas de contenção de solo representam o avanço da engenharia em meio a urbanização no país. A cortina atirantada possui desempenho comprovado na área de estabilização de taludes quando se trata de vencer grandes alturas e cargas elevadas. Este estudo aborda o dimensionamento estrutural de uma cortina atirantada, empregando, para isto, as normas vigentes de concreto armado, tirantes ancorados e estabilidade de encostas, além do método de dimensionamento geotécnico desenvolvido por Costa Nunes, executado com auxílio de planilha no Excel e verificação de estabilidade através do software desenvolvido pela empresa FINE Engineering, para resolução de problemas geotécnicos, o GEO5. Inicialmente é feita uma revisão bibliográfica acerca dos tipos de cortinas empregadas, métodos de verificação de estabilidade e métodos de cálculo geotécnico e estrutural. A partir das forças de estabilização obtidas pelo método brasileiro de atirantamento, selecionou-se o tirante monobarra adequado, calculou-se a carga atuante na parede, e através do software Ftool foram obtidas as forças internas para o dimensionamento estrutural. Evidenciou-se que o projeto estrutural precisa ser devidamente calculado para atender aos critérios de protensão dos tirantes e carregamentos.
Abstract: The soil containment structures represent the advancement of engineering amidst urbanization in the country. The anchored curtain has proven performance in the area of slope stabilization , particularly in overcoming significant heights and high loads. This study addresses the structural design of an anchored curtain, employing current standards for reinforced concrete, anchored tie rods, slope stability, and the geotechnical design method developed by Costa Nunes. The calculations were carried out using an Excel spreadsheet and stability verification through the software developed by FINE Engineering, specifically the GEO5, for solving geotechnical problems. Initially, a literature review is conducted on the types of curtains used, stability verification met hods, and geotechnical and structural calculation methods. Based on the stabilization forces obtained through the Brazilian anchoring method, an appropriate single bar tie rod was selected. The acting load on the wall was calculated, and internal forces fo r structural design were obtained using the Ftool software. It became evident that the structural design needs to be accurately calculated to meet the criteria for tie rod prestressing and loading requirements.
Keywords: Estrutura de contenção
Containment structure
Tirantes
Tie Rods
Estabilidade de talude
Slope stability
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/34969
Appears in Collections:Curso de Bacharelado em Engenharia Civil - CCTA

Files in This Item:
File Description SizeFormat 
LUCAS WESLEY DE SOUZA ARRUDA - TCC - ENGENHARIA CIVIL 2023.pdfLucas Wesley de Souza Arruda – TCC – Engenharia Civil 2023.1.64 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.