Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/37992
Full metadata record
DC FieldValueLanguage
dc.creator.IDDANTAS, F. B.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/0670700800927974pt_BR
dc.contributor.advisor1FERNANDES JÚNIOR, Damásio.-
dc.contributor.advisor1IDFERNANDES Jr., D.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3630883713661678pt_BR
dc.contributor.advisor2NEVES, Washington Luiz Araújo.-
dc.contributor.advisor2IDNEVES, W. L. A.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/3107104665517286pt_BR
dc.contributor.referee1SOUZA, Benemar Alencar de.-
dc.contributor.referee2BRITO, Nubia Silva Dantas.-
dc.contributor.referee3ASADA, Eduardo Nobuhiro-
dc.contributor.referee4VIEIRA JÚNIOR , José Carlos de Melo.-
dc.description.resumoPropõe-se nesta Tese um método paraainstalação ótima de umaouvárias microrredes em sistemas de distribuição. As microrredes incluem arranjos de geração eólica e fotovoltaica e de armazenamento de energia elétrica. O método proposto contribui para reduzir as perdas técnicas de energia elétrica num período de 10 anos e para avaliar o desempenho das microrredes com uma alta penetração de energia renovável, além de ter flexibilidade para alterar as configurações das microrredes. O método considera diferentes níveis de penetração, pois o futuro do sistema de potência exigirá esta condição. A meta-heurística Algoritmo Genético foi utilizada como ferramenta para a resolução do problema de otimização proposto. Para realizar o cálculo do fluxo de potência é utilizado o software OpenDSS, que deve respeitar os limites de tensão impostos pela Agência Nacional de Energia Elétrica- ANEEL. Os estudos de caso foram divididos considerando diferentes níveis de penetração máxima de energia renovável. A análise dos resultados mostrou que o método proposto foi capaz de instalar as microrredes reduzindo as perdas de energia elétrica, bem como estimando os custos das soluções ótimas encontradas após o processo de otimização. Um diferencial do método está na possibilidade de utilizá-lo mesmo com uma alta penetração da geração renovável, além de considerar um horizonte de 10 anos. Ométodo proposto é simples, rápido e eficiente, e foi aplicado ao sistema teste IEEE 123 barras, sendo capaz de definir a quantidade e a localização das microrredes, obtendo êxito nos estudos de caso.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétricapt_BR
dc.titleUm método para instalação ótima de microrredes para minimizar as perdas de energia em sistemas de distribuiçãopt_BR
dc.date.issued2024-04-25-
dc.description.abstractThis Thesis proposes a method for the optimal installation of one or several microgrids in distribution systems. Microgrids include wind and photovoltaic generation and electrical energy storage arrangements. The proposed method contributes to reducing technical losses of electrical energy over a period of 10 years and to evaluating the performance of microgrids with a high penetration of renewable energy, in addition to having the f lexibility to change microgrid configurations. The method considers different levels of penetration, as the future of the power system will require this condition. The Genetic Algorithm meta-heuristic was used as a tool to solve the proposed optimization problem. To calculate the power flow, the OpenDSS software is used, which must respect the voltage limits imposed by the National Electric Energy Agency- ANEEL. The case studies were divided considering different levels of maximum renewable energy penetration. Analysis of the results showed that the proposed method was able to install microgrids reducing electrical energy losses, as well as estimating the costs of the optimal solutions found after the optimization process. A differentiator of the method is the possibility of using it even with a high penetration of renewable generation, in addition to considering a 10-year horizon. The proposed method is simple, fast and efficient, and was applied to the IEEE 123 bus test system, being able to define the number and location of microgrids, achieving success in the case studies.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/37992-
dc.date.accessioned2024-09-24T18:46:20Z-
dc.date.available2024-09-24-
dc.date.available2024-09-24T18:46:20Z-
dc.typeTesept_BR
dc.subjectSistema de distribuiçãopt_BR
dc.subjectOpenDSSpt_BR
dc.subjectMicrorredespt_BR
dc.subjectGeração distribuídapt_BR
dc.subjectAlgoritmo Genéticopt_BR
dc.subjectDistribution systempt_BR
dc.subjectOpenDSSpt_BR
dc.subjectMicrogridpt_BR
dc.subjectDistributed generationpt_BR
dc.subjectGenetic Algorithmpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorDANTAS, Felipe Barros.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeA method for optimal microgrid installation to minimize microgrids Energy losses in distribution systemspt_BR
dc.identifier.citationDANTAS, Felipe Barros. Um método para instalação ótima de microrredes para minimizar as perdas de energia em sistemas de distribuição. 2024. 139 f. Tese (Doutorado em Engenharia Elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande, Paraíba, Brasil, 2024.pt_BR
Appears in Collections:Doutorado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
FELIPE BARROS DANTAS - TESE (PPGEE) 2024.pdf4.49 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.