dc.description.resumo | O objetivo deste trabalho, é desenvolver uma técnica de otimização dos parâmetros de um sistema de medição de alta tensão de impulso, utilizando um divisor de potencial resistivo. Os parâmetros considerados nesse sentido são: a geometria dos eletrodos de blindagem, as resistências de amortecimento e a resistência do ramo de baixa-tensão do divisor. Uma nova técnica de otimização do sistema de medição foi desenvolvida baseada no modelo do circuito equivalente de um divisor de potencial resistivo. Aplicou-se esta técnica para a obtenção dos valores Ótimos dos parâmetros de um sistema de medição para impulsos de 1MV. Os parâmetros ótimos e a resposta degrau do sistema de medição foram calculados. Utilizando-se os parâmetros Ótimos foi construído um divisor de potêncial resistivo, através do qual obteve-se a medição da resposta degrau e do tempo de resposta. 0 tempo de resposta obtido foi menor do que 20ns. | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | Centro de Engenharia Elétrica e Informática - CEEI | pt_BR |
dc.publisher.program | PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA | pt_BR |
dc.publisher.initials | UFCG | pt_BR |
dc.title | Otimização dos parâmetros de um divisor de potencial resistivo. | pt_BR |
dc.date.issued | 1984-06 | - |
dc.description.abstract | The main objective of this thesis is to develop a technique for optimizing the parameters of a measuring systern for high impulse voltages using a resistive divider. The parameters considered in this sense are: the shielding electrode geometry, the damping resistances, and the resistance of the low voltage arm. A new technique for optimizing a measuring system for high impulse vo.ltage is developed in using an equivalent circuit model of a resistive voltage divider. This technique has been applied to obtain the optimum parameters- values of a measuring system for 1MV impulses. The optimum response and the step-response of the measuring system have been calculated. Using the optimum parameters-values a resistive voltage divider was constructed. The step-response of the measuring system and the response time were obtained. The measured response time less than 20ns. | pt_BR |
dc.identifier.uri | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/4114 | - |
dc.date.accessioned | 2019-06-04T15:32:21Z | - |
dc.date.available | 2019-06-04 | - |
dc.date.available | 2019-06-04T15:32:21Z | - |
dc.type | Dissertação | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.creator | REIS, Laurinda Lúcia Nogueira dos. | - |
dc.publisher | Universidade Federal de Campina Grande | pt_BR |
dc.language | por | pt_BR |
dc.title.alternative | Optimization of the parameters of a resistive potential divider. | pt_BR |
dc.identifier.citation | REIS, Laurinda Lúcia Nogueira dos. Otimização dos parâmetros de um divisor de potencial resistivo. 1984. 211f. (Dissertação de Mestrado em Engenharia Elétrica), Curso de Pós-Graduação em Engenharia Elétrica, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba – Campus II - Campina Grande - PB - Brasil,1984. | pt_BR |