Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41385
Title: | Determinação do bulbo molhado em nitossolo vermelho distroférrico utilizando-se a técnica de TDR, em laboratório. |
Other Titles: | Wetted front position in nitossolo vermelho distroférrico profile, identified from laboratory soil moisture measurements by TDR. |
???metadata.dc.creator???: | MARQUES, Odair J. ANAMI, Marcelo H. GONÇALVES, Antonio Carlos A. FOLEGATTI, Marcos V. |
Keywords: | Bulbo molhado;Nitossolo vermelho distroférrico;Irrigação por gotejamento;Técnica de TDR;Wet bulb;Dystroferric red soil;Drip irrigation;TDR technique |
Issue Date: | 2006 |
Publisher: | Universidade Federal de Campina Grande |
Citation: | MARQUES, Odair J; ANAMI, Marcelo H; GONÇALVES, Antonio Carlos A; FOLEGATTI, Marcos V. Determinação do bulbo molhado em nitossolo vermelho distroférrico utilizando-se a técnica de TDR, em laboratório. In: XXXV CONGRESSO BRASILEIRO DE ENGENHARIA AGRÍCOLA. 35., 2006, João Pessoa - PB. Anais [...]. João Pessoa - PB: Universidade Federal da Paraíba, 2006. Simpósio Temático: Engenharia de água e solo. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41385 |
???metadata.dc.description.resumo???: | Dada à importância dos recursos hídricos, visto a sua importância para a agropecuária e para a existência do ser humano, a adoção do método de irrigação localizada tem sido cada vez mais freqüente. Para se dimensionar corretamente os sistemas de irrigação empregados, a determinação das dimensões do bulbo molhado é fundamental. Procurou-se avaliar, para um NITOSSOLO VERMELHO Distroférrico, as dimensões de bulbo molhado formado a partir de uma fonte pontual de água, empregando-se a técnica de TDR para medida da umidade no perfil do solo. As vazões utilizadas foram de 2,4; 3,6 e 4,8 L h-1 por 8 horas de aplicação e volumes de 19,2; 28,8 e 38,4 litros, respectivamente. Foi construído um lisímetro de PVC com dimensões de 1,10 x 1,00 x 0,90 m onde foram colocadas sondas de TDR a cada 5 cm de baixo para cima e a cada 10 cm na superfície. Os resultados mostraram as dimensões (diâmetro x profundidade) do bulbo molhado em média 0,76 x 0,45 m, 0,92 x 065 m e 0,96 x 081 m, para as vazôes de 2,4, 3,6 e 4,8 L h-1, respectivamente. A utilização da técnica de TDR é altamente conveniente para medir as dimensões do bulbo molhado em laboratório. |
Abstract: | Since water is the most important natural resource to agriculture and to existence of humanity in general, to prevent unneeded water use, localized irrigation method has been largely applied in the world. To design the trickle irrigation systems adequately, designer must identify the water front position in the soil profile, any time after beginning to apply water from a punctual water source. Then, they dimensions were measured at a NITOSSOLO VERMELHO Distroférrico profile, using a TDR technique to measure soil moisture. The used outflows had been of 2.4; 3.6 and 4.8 L h-1 for 8 hours of application and volume of 19.2; 28.8 and 38.4 liters, respectively. Lysimeter of PVC with dimensions of 1.10 x 1.00 x 0.90 m was constructed and was install TDR probes to each 5 cm of low for top and to each 10 cm in the surface. The results showed that wetted front position in space, after water application (depth x diameter) was, in average 0.76 x 0.45 m, 0.92 x 0.65 m and 0.96 x 0.81 m for the outflows of 2.4, 3.6 and 4.8 L h-1, respectively. TDR techniques can be used to identify, with adequate precision, the wetted front in the soil profile, during application of water from punctual source. |
Keywords: | Bulbo molhado Nitossolo vermelho distroférrico Irrigação por gotejamento Técnica de TDR Wet bulb Dystroferric red soil Drip irrigation TDR technique |
???metadata.dc.subject.cnpq???: | Engenharia Agrícola. |
URI: | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41385 |
Appears in Collections: | 35º CONBEA 2006 - Simpósio Temático - Engenharia de Água e Solo |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
DETERMINAÇÃO DO BULBO MOLHADO - XXXV CONBEA UFCG 2006.pdf | Determinação do bulbo molhado em nitossolo vermelho distroférrico utilizando-se a técnica de TDR, em laboratório. - XXXV CONBEA UFCG 2006 | 55.46 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.