Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41944
Title: | Desempenho de reatores anaeróbios de fluxo ascendente com manta de lodo em dois estágios tratando águas residuárias de suinocultura. |
Other Titles: | Performance of two-stage upflow anaerobic sludge blanket reactors treating swine wastewater. |
???metadata.dc.creator???: | SANTANA, A. M. de. OLIVEIRA, R. A de. |
Keywords: | Reator anaeróbio de fluxo ascendente;Digestão anaeróbia;Reator UASB;Resíduos de suínos;Efluentes - suinocultura;Suinocultura - resíduos;Upflow anaerobic reactor;Anaerobic digestion;UASB reactor;Swine waste;Effluents - pig farming;Pig farming - waste |
Issue Date: | 2006 |
Publisher: | Universidade Federal de Campina Grande |
Citation: | SANTANA, A. M. de; OLIVEIRA, R. A de. Desempenho de reatores anaeróbios de fluxo ascendente com manta de lodo em dois estágios tratando águas residuárias de suinocultura. In: XXXV CONGRESSO BRASILEIRO DE ENGENHARIA AGRÍCOLA. 35., 2006, João Pessoa - PB. Anais [...]. João Pessoa - PB: Universidade Federal da Paraíba, 2006. Simpósio Temático: Saneamento e Controle Ambiental (Recursos Naturais e Meio Ambiente). Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41944 |
???metadata.dc.description.resumo???: | O objetivo deste trabalho foi avaliar o desempenho de dois reatores anaeróbios de fluxo ascendente com manta de lodo (UASB) em escala piloto com volumes de 908 L e 188 L, instalados em série, alimentados com águas residuárias de suinocultura com concentrações médias de sólidos suspensos totais (SST) variando de 2216 mg L-1 a 7131 mg L-1 e submetidos a tempos de detenção hidráulica (TDH) de 62,3 e 31,1 h, no primeiro reator, e de 12,9 e 6,5 h, no segundo reator. As eficiências médias de remoção de DQOtotal variaram de 74,0% a 89,6% no Reator 1 e de 34,3% a 45,1% no Reator 2, resultando em valores médios de 86,6% a 93,1% para o sistema de tratamento em dois estágios, com carga orgânica volumétrica (COV) na faixa de 3,40 a 14,44 kg DQOtotal m-3 reator d-1 no primeiro reator. Para a remoção de SST as eficiências variaram de 85,6 a 87,8 % para o sistema de tratamento anaeróbio em dois estágios. |
Abstract: | The objective of this work was to evaluate the acting of two upflow anaerobic sludge blanket reactors (UASB) in pilot scale with volumes of 908 L and 188 L, installed in series, fed with swine wastewater with medium concentrations of total suspended solids (TSS) ranging of 2216 mg L-1 to 7131 mg L-1 and submitted to hydraulic detention times (HDT) of 62.3 and 31.1 h, in the first reactor, and of 12.9 and 6.5 h, in the second reactor. The removal efficienty of CDOtotal ranging from 74.0% to 89.6% in the Reactor 1 and of 34.3% to 45.1% in the Reactor 2, resulting in average values from 86.6% to 93.1% the treatment system in two stage with organic volumetric load (OVL) ranging from 3.40 to 14.44 kg CODtotal m-3 reactor d-1 in the Reactor 1. For the removal of TSS efficiency they varied from 85.6 to 87.8% to the system of two stages treatment anaerobic. |
Keywords: | Reator anaeróbio de fluxo ascendente Digestão anaeróbia Reator UASB Resíduos de suínos Efluentes - suinocultura Suinocultura - resíduos Upflow anaerobic reactor Anaerobic digestion UASB reactor Swine waste Effluents - pig farming Pig farming - waste |
???metadata.dc.subject.cnpq???: | Engenharia Agrícola. |
URI: | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41944 |
Appears in Collections: | 35º CONBEA 2006 - Simpósio Temático - Saneamento e Controle Ambiental (Recursos Naturais e Meio Ambiente) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
DESEMPENHO DE REATORES ANAERÓBIOS DE FLUXO - XXXV CONBEA UFCG 2006.pdf | Desempenho de reatores anaeróbios de fluxo ascendente com manta de lodo em dois estágios tratando águas residuárias de suinocultura. - XXXV CONBEA UFCG 2006 | 97.97 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.