Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/447
Full metadata record
DC FieldValueLanguage
dc.creator.IDRODRIGUES, S. A.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/5027140030535720pt_BR
dc.contributor.advisor1FREIRE, Raimundo Carlos Silvério.-
dc.contributor.advisor1IDFREIRE, R. C. S.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4016576596215504pt_BR
dc.contributor.advisor2LUCIANO, Benedito Antônio.-
dc.contributor.advisor2IDLUCIANO, B. A.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/2390722791029216pt_BR
dc.description.resumoDe acordo com a Administração Federal de Alimentos e Medicamentos estadunidense (Food and Drug Administration – FDA), bombas de infusão são consideradas atualmente os dispositivos médicos cuja segurança é a mais crítica, devido à natureza de suas operações e os riscos a elas associados. O projeto destes dispositivos ainda é uma questão em aberto e várias iniciativas de melhoria estão sob investigação. No entanto, as especificações de tais sistemas ainda não estão adaptadas ao estado-da-arte do desenvolvimento de sistemas arquiteturais. Por exemplo, nesta pesquisa não foi possível identificar qualquer projeto que atenda aos padrões, considerando as especificação e documentação de arquiteturas de sistemas e de software durante o processo de engenharia. Em face desta situação, nesta dissertação é apresentada a especificação funcional de uma arquitetura para bombas de infusão que pode ser realizada mediante o emprego de várias tendências tecnológicas para esses produtos, a fim de melhorar a segurança. A especificação arquitetural apresentada foi validada pelo desenvolvimento de um protótipo multicanal de uma bomba de infusão que pode ser programada utilizando dados obtidos a partir de um serviço web, usando um aplicativo de celular, como controle remoto, que permita mudar os parâmetros de infusão de acordo com dados da prescrição médica. Assim, a principal contribuição deste trabalho pode ser apresentada como uma arquitetura distribuída para esse tipo de dispositivo, permitindo a integração com registros eletrônicos de saúde para o domínio de sistemas embarcados que implicam em redução de erros durante a atividade de programação.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.pt_BR
dc.titleSistemas de acionamento para bombas de infusão de múltiplos canais.pt_BR
dc.date.issued2014-09-
dc.description.abstractAccording to the Food and Drug Administration - FDA, infusion pumps are currently considered the most safety-critical medical device due to the nature of their operations and associated risks. Design of these devices is still an open question and several improvement initiatives are under research. However, the released specifications of such systems are not yet adapted to the current state-of-art systems architectural developments. For example, in this work, we could not identify any project meeting the patterns of views and viewpoints for specification and documentation of system and software architectures during the engineering process. Due to this, this dissertation proposes a functional specification of an architecture for infusion pumps that can be realized through several technological trends for these products in order to improve safety. The presented architectural specification was validated by the development of a multichannel prototype of an infusion pump that can be programmed through data retrieved from a web service using a mobile application as a remote control and changing the infusion parameters according to medical prescription. Thus, the main contribution of this paper can be presented as a distributed architecture for this sort of device, allowing early integration with Electronic Health Records for the embedded systems domain implying in risk reductions during the programming activity.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/447-
dc.date.accessioned2018-04-21T13:58:34Z-
dc.date.available2018-04-21-
dc.date.available2018-04-21T13:58:34Z-
dc.typeDissertaçãopt_BR
dc.subjectArquitetura de softwarept_BR
dc.subjectBombas de infusãopt_BR
dc.subjectDispositivo multicanalpt_BR
dc.subjectDispositivos médico - bomba de infusãopt_BR
dc.subjectInfusion pumpspt_BR
dc.subjectMulti-channel devicept_BR
dc.subjectArquitectura de software-
dc.subjectBombas de infusion-
dc.subjectDispositivo multicanal-
dc.rightsAcesso Abertopt_BR
dc.creatorRODRIGUES, Sidney Aciole.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeDrive systems for multi-channel infusion pumps.pt_BR
dc.identifier.citationRODRIGUES, Sidney Aciole. Sistemas de acionamento para bombas de infusão de múltiplos canais. 2014. 60f. (Dissertação de Mestrado em Engenharia Elétrica), Programa de Pós-graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2014.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
SIDNEY ACIOLE RODRIGUES - DISSERTAÇÃO PPGEE 2014.pdfSidney Aciole Rodrigues - Dissertação PPGEE 20142.7 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.