Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/582
Full metadata record
DC FieldValueLanguage
dc.creator.IDSANTOS, A. K. X.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/4184864506074526pt_BR
dc.contributor.advisor1NEVES, Washington Luiz Araújo.
dc.contributor.advisor1IDNEVES, W. L. A.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3107104665517286pt_BR
dc.contributor.advisor2FERNANDES JÚNIOR, Damásio.
dc.contributor.advisor2IDFERNANDES Jr., D.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/3630883713661678pt_BR
dc.contributor.referee1OLESKOVICZ, Mário.
dc.contributor.referee2BOAVENTURA, Wallacy do Couto.
dc.contributor.referee3BRITO, Nubia Silva Dantas.
dc.contributor.referee4MOTA, Wellington Santos.
dc.description.resumoUm método de estimação fasorial é proposto para ser utilizado em relés digitais de proteção. Este método tem o objetivo de melhorar a característica de rejeição de componentes indesejáveis do sinal, que são introduzidas durante faltas e manobras nos sistemas elétricos de potência e podem comprometer o desempenho dos sistemas de proteção. São realizadas comparações entre o método proposto e outros quatro métodos de estimação fasorial, em relação às respostas no tempo e frequência. Para as comparações de resposta no tempo são utilizados sinais analíticos provenientes do MATrix LABoratory (MATLAB®) e sinais simulados provenientes do Alternative Transients Program (ATP). Um relé de distância foi implementado utilizando a linguagem MODELS do ATP para avaliar o desempenho do relé, utilizando o método proposto e demais métodos avaliados. A partir de alguns parâmetros usados para avaliar quantitativamente os métodos de estimação, observou-se que o método proposto apresenta bons resultados em termos de precisão e velocidade de convergência, com resposta no tempo compatível com os demais métodos comumente utilizados. A resposta em frequência do método proposto se apresenta mais seletiva em relação aos demais, por apresentar menores lóbulos entre as harmônicas e uma banda de passagem mais estreita em torno da frequência fundamental. Outra vantagem do método proposto é que ele é de fácil programação e permite que os usuários alterem parâmetros de projeto de acordo com suas necessidades.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétricapt_BR
dc.subject.cnpqCiênciaspt_BR
dc.titleUm novo método de estimação fasorial para uso em relés digitais de proteção.pt_BR
dc.date.issued2016-10-21
dc.description.abstractA phasor estimation method is proposed to be used in digital relays for power system protection. It aims to improve the characteristic of filtering out undesirable frequency components of signals, which are introduced during faults and switching events in electric power systems that may compromise the performance of the protection systems. Comparisons are made in relation to time response and frequency response for the proposed method and four phasor estimation methods. In relation to response time are used analytical signals from MATrix LABoratory (MATLAB®) and simulated signals from Alternative Transients Program (ATP). A distance relay was implemented by using the MODELS language in ATP to evaluate the performance of the relay. From some parameters used to evaluate the estimation methods, it was observed that the proposed method shows good results in terms of accuracy and convergence speed, with response time compatible with other methods. The frequency response of the proposed method appears to be more selective than those of the others methods because it presents lower lobes between the harmonics and a narrower pass band around the fundamental frequency. Another advantage of the proposed method is that it can be easily programmed, allowing users to change design parameters according to their needs.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/582
dc.date.accessioned2018-05-04T19:00:50Z
dc.date.available2018-05-04
dc.date.available2018-05-04T19:00:50Z
dc.typeTesept_BR
dc.subjectResposta no tempopt_BR
dc.subjectResposta em frequênciapt_BR
dc.subjectRelé de distânciapt_BR
dc.subjectSistemas elétricos - proteçãopt_BR
dc.subjectPower system protectionpt_BR
dc.subjectDistance relaypt_BR
dc.subjectFrequency responsept_BR
dc.subjectTime responsept_BR
dc.rightsAcesso Abertopt_BR
dc.creatorCAMPOS, Alana Kelly Xavier Santos.
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.description.sponsorshipCapespt_BR
dc.identifier.citationCAMPOS, A. K. X. S. Um novo método de estimação fasorial para uso em relés digitais de proteção. 158 f. Tese (Doutorado em Engenharia Elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e informática, Universidade Federal de Campina Grande, Paraíba, Brasil, 2016.pt_BR
Appears in Collections:Doutorado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
ALANA KELLY XAVIER SANTOS CAMPOS – TESE (PPGEE) 2016.pdfAlana Kelly Xavier Santos Campos - Tese PPGEE 20163.87 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.