Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/667
Title: Estudo da qualidade de água residuária doméstica pós-tratada em fluxo descendente intermitente.
Other Titles: Quality study of post-treated domestic wastewater in flow down flashing.
???metadata.dc.creator???: SOUSA, Eliana Pereira de.
???metadata.dc.contributor.advisor1???: QUEIROZ, Manoel Moisés Ferreira de.
???metadata.dc.contributor.advisor2???: ARAÚJO, Alfredina dos Santos.
???metadata.dc.contributor.referee1???: MARACAJÁ, Patrício Borges.
???metadata.dc.contributor.referee2???: PEREIRA JUNIOR, Ednaldo Barbosa.
Keywords: Esgoto doméstico;Filtro intermitente de areia;Água residuária doméstica;Fluxo descendente intermitente;Pós-tratamento de efluente;Tanque séptico;Post-treated domestic wastewater;Domestic wastewater;Septic tank
Issue Date: 2015
Publisher: Universidade Federal de Campina Grande
Citation: SOUSA, Eliana Pereira de. Estudo da qualidade de água residuária doméstica pós-tratada em fluxo descendente intermitente. 2015. 93f. . (Dissertação de Mestrado Profissional), Programa de Pós-graduação em Sistemas Agroindustriais, Centro de Ciências e Tecnologia Agroalimentar, Universidade Federal de Campina Grande – Pombal – Paraíba – Brasil, 2015.
???metadata.dc.description.resumo???: A presente pesquisa investigou o desempenho do pós-tratamento de efluente de tanque séptico em filtros de areia de fluxos intermitentes, visando obter um esgoto tratado com qualidade adequada para reuso na irrigação. O esgoto doméstico foi proveniente do bloco de aulas II do Centro de Ciências e Tecnologia Agroalimentar (CCTA), da Universidade Federal de Campina Grande (UFCG). O controle de entrada do fluxo no sistema também foi quantificado. O sistema experimental foi constituído de um tanque séptico, três filtros de areia com fluxo intermitente e uma caixa de armazenamento. Os três filtros aeróbios de areia foram preenchidos com brita e areia na seguinte proporção: 10 cm de brita nº 1 na base, 50 cm de areia na porção mediana e 5 cm de brita nº 0 na porção superior. A areia utilizada nos três filtros foi a mesma, sendo peneirada numa peneira com diâmetro de 0,50 mm. O primeiro filtro recebeu 200 L/dia (50 L a cada 6hs) de efluente do tanque séptico, o segundo filtro recebeu 150 L/dia (50 L a cada 8hs) e o terceiro filtro recebeu 100 L/dia (50 L a cada 12hs). Realizaram-se campanhas de medição, no período de Novembro/2014 a Fevereiro/2015 para caracterizar os efluentes nos aspectos físico-químicos e microbiológicos como indicadores de transformação da qualidade da água. Os parâmetros analisados foram: OD, temperatura, turbidez, pH, CE, cor, dureza total, Ca, Mg, cloretos, N, Na, K, P, DQO, DBO5, CT, CTT e E.coli. A análise de variância (ANOVA) foi realizada para comparar as concentrações de todos os parâmetros entre os efluentes, com nível de significância de 5%. Temperatura, turbidez, CE, cor, dureza total, Ca, Mg, cloretos, Na, K, P, DQO, DBO5, CT, CTT e E.coli não apresentaram diferenças estatísticas significantes. O OD apresentou significância. O N, muita significância e o pH, extrema significância estatística. Os filtros reduziram as concentrações de nutrientes, matéria orgânica e microorganismos patógenos, porém, com os reduzidos tempos de intermitências adotados não foi possível encontrar diferenças estatísticas entre os tratamentos. Os valores encontrados não foram compatíveis com os recomendados para uso na agricultura, segundo a Resolução do CONAMA.
Abstract: This research investigated the performance of the post-treatment of septic tank effluent sand filters intermittent flows, to obtain a treaty with sewage quality suitable for reuse in irrigation. The sewage was coming from the classes of block II of the Center for Science and Technology Agrifood (CCTA), the Federal University of Campina Grande (UFCG). The input flow control in the system was also quantified. The experimental system was composed of a septic tank of three sand filters with intermittent flow and a storage box. The three aerobic sand filters were filled with gravel and sand at the following ratio: 10 cm crushed base # 1, 50 cm in the middle portion sand and crushed stone No. 5 0 cm in the upper portion. The sand used in the three filters was the same, being sieved through a sieve with a diameter of 0.50 mm. The first filter received 200 L / day (50 L each 6am) of effluent from septic tank, the second filter received 150 L / day (50 L every 8h) filter and the third received 100 L / day (50 L each 12pm). There were measurement campaigns, from November / 2014 to February / 2015 to characterize the effluents in the physical, chemical and microbiological aspects as processing indicators of water quality. The parameters analyzed were: OD, temperature, turbidity, pH, EC, color, total hardness, Ca, Mg, chlorides, N, Na, K, P, COD, BOD 5, CT, CTT and E. coli. The analysis of variance (ANOVA) was performed to compare the concentrations of all the parameters in the effluent, at 5% significance level. Temperature, turbidity, EC, color, total hardness, Ca, Mg, chlorides, Na, K, P, COD, BOD 5, CT, CTT and E. coli showed no statistically significant differences. The OD showed significant. The N, much significance and the pH, extreme statistical significance. The filters reduced the concentrations of nutrients, organic matter and pathogenic microorganisms, but with reduced flickers adopted times could not find statistical differences between treatments. These values were not compatible with those recommended for agricultural use, according to CONAMA resolution.
Keywords: Esgoto doméstico
Filtro intermitente de areia
Água residuária doméstica
Fluxo descendente intermitente
Pós-tratamento de efluente
Tanque séptico
Post-treated domestic wastewater
Domestic wastewater
Septic tank
???metadata.dc.subject.cnpq???: Ciências Agrárias
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/667
Appears in Collections:Mestrado Profissional em Sistemas Agroindustriais (Pombal).

Files in This Item:
File Description SizeFormat 
ELIANA PEREIRA DE SOUSA - DISSERTAÇÃO PPGSA PROFISSIONAL 2015.pdfEliana Pereira de Sousa - Dissertação PPGSA Profissional 2015.1.52 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.