Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/8133
Full metadata record
DC FieldValueLanguage
dc.creator.IDRODRIGUES, A. B.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/3268095563013249pt_BR
dc.contributor.advisor1MEIRA, Celeide Maria Belmont Sabino.-
dc.contributor.advisor1IDMEIRA, C. M. B. S.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/5581322712159667pt_BR
dc.contributor.advisor2OLIVEIRA, Rui de.-
dc.contributor.referee1COURA, Mônica de Amorim.-
dc.contributor.referee2ATHAYDE JÚNIOR, Gilson Barbosa.-
dc.description.resumoO presente trabalho tem o objetivo de contribuir para as ações de vigilância da qualidade da água do sistema de abastecimento do Hospital Dom Luiz Gonzaga Fernandes localizado na cidade de Campina Grande-PB, através da utilização de uma metodologia de análise de risco. Foram escolhidos quatorze pontos de amostragem (P0, P1, P3, P4, P5, P6, P7, P8, P9, P10, P11, P12 e P13), tendo sido analisados os indicadores cloro residual livre (CRL), cloro residual combinado (CRC), turbidez, pH, bactérias heterotróficas e coliformes totais no período de março a junho de 2013. Foi então aplicado o método Análise do Modo e Efeito de Falhas (FMEA) para definir os riscos do sistema de abastecimento e classificá-los quanto à sua importância. Posteriormente, foi empregado o método da média aritmética para estimar o risco total de cada ponto de amostragem, baseado na importância dos riscos listados e nos valores da média dos indicadores analisados. Um mapa foi gerado para representar melhor a distribuição do risco no sistema de abastecimento de água do hospital. Todos os pontos foram classificados como de risco alto. Os perigos mais influentes na categorização de risco foram baixa concentração de CRL, alta concentração de bactérias heterotróficas e presença de coliformes totais.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologia e Recursos Naturais - CTRNpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTALpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Civil e Ambiental-
dc.titleAvaliação de risco da qualidade da água de abastecimento de um hospital público regional de urgência e emergência.pt_BR
dc.date.issued2014-02-
dc.description.abstractThis work aims contribute for surveillance water quality’s measures for the supply system of Dom Luiz Gonzaga Fernandes Hospital, located in the Campina Grande city, Paraíba state, Brazil, through of the risk analysis methodology. Fourteen sampling points were chosen (P0, P1, P3, P4, P5, P6, P7, P8, P9, P10, P11, P12 e P13), have been analyzed the indicators free residual chlorine (FRC), combined residual chlorine (CRC), turbidity, pH, total coliform and heterotrophic bacteria on the period of March to June 2013. Therefore was applied the method of Failure Mode and Effect Analysis (FMEA) defining the risks of the supply system and categorize them in terms of their importance. Subsequently, it was employed the method of arithmetic mean for estimate the total risk of each sampling point , based on the importance of the risks listed and the values of mean of the indicators analyzed. A map was created to better represent the distribution of risks at the hospital water supply system. All sampling points were classified as high risk. The most influential hazards in the categorization of risk were the low concentration of CRL, high concentration of heterotrophic bacteria and the presence of total coliforms.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/8133-
dc.date.accessioned2019-10-16T13:21:08Z-
dc.date.available2019-10-16-
dc.date.available2019-10-16T13:21:08Z-
dc.typeDissertaçãopt_BR
dc.subjectQualidade da Água - Hospital-
dc.subjectSaúde Ambiental-
dc.subjectAnálise de Risco-
dc.subjectMetodologia FMEA-
dc.subjectTabela de Escores-
dc.subjectWater Quality - Hospital-
dc.subjectRisk analysis-
dc.subjectFMEA Methodology-
dc.subjectScoring Table-
dc.subjectEnvironmental Health-
dc.rightsAcesso Abertopt_BR
dc.creatorRODRIGUES, Alesca Barbosa.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeRisk assessment of the supply water quality of a regional public emergency hospital.pt_BR
dc.identifier.citationRODRIGUES, Alesca Barbosa. Avaliação de risco da qualidade da água de abastecimento de um hospital público regional de urgência e emergência. 2014. 96f. (Dissertação) Mestrado em Engenharia Civil e Ambiental, Programa de Pós-Graduação em Engenharia Civil e Ambiental, Universidade Federal de Campina Grande - Campina Grande - Paraíba - Brasil, 2014. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/8133pt_BR
Appears in Collections:Mestrado em Engenharia Civil e Ambiental.

Files in This Item:
File Description SizeFormat 
ALESCA BARBOSA RODRIGUES - DISSERTAÇÃO PPGECA 2014.pdfAlesca Barbosa Rodrigues - Dissertação PPGECA 2014.2.72 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.