Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/8167
Full metadata record
DC FieldValueLanguage
dc.creator.IDRAPHAEL L. A. REIS.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/1139577841043865pt_BR
dc.contributor.advisor1NEVES, Washington Luiz Araújo.-
dc.contributor.advisor1FERNANDES JÚNIOR, Damásio.-
dc.contributor.advisor1IDNEVES, W. L. A.pt_BR
dc.contributor.advisor1IDFERNANDES JÚNIOR, D.-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3107104665517286pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3630883713661678-
dc.contributor.referee1COSTA, Edson Guedes da.-
dc.contributor.referee2BRITO, Nubia Silva Dantas.-
dc.description.resumoNeste trabalho é avaliada a influência de diferentes modelos de Transformadores de Potencial Capacitivos (TPC) de 230 kV e 500 kV e filtros anti-aliasing sobre um método de localização de faltas de dois terminais baseado na teoria de ondas viajantes, considerando-se dados sincronizados, quando apenas os sinais de tensão estão disponíveis para medição. Vários cenários de faltas foram simulados no Alternative Transients Program (ATP). Em cada caso, a localização do curto-circuito foi estimada tomando como entrada do algoritmo localizador os sinais de tensão do primário, secundário e secundário filtrados dos TPC. Para possibilitar um estudo mais detalhado, três métodos de detecção de faltas baseados na teoria de ondas viajantes foram utilizados. Dos resultados obtidos, constata-se que as estimações dos locais do distúrbio são diretamente influenciadas pela resposta em frequência dos TPC e do conjunto TPC+filtro anti-aliasing, apresentando melhores estimativas nos casos em que há amplificação dos componentes de alta frequência da tensão secundária dos equipamentos.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica-
dc.titleInfluência de transformadores de potencial capacitivos e filtros anti-aliasing sobre métodos de localização de faltas baseados na teoria de ondas viajantes.pt_BR
dc.date.issued2015-07-31-
dc.description.abstractIn this work, the influence of 230 kV and 500 kV Coupling Capacitor Voltage Transformers (CCVT) and anti-aliasing filters on a two-terminal synchronized travelling wave-based fault location algorithm is analyzed, when only voltage measurements are available. Several fault scenarios were simulated using the Alternative Transients Program (ATP). In each case, the fault location was estimated using two-terminal synchronized voltage samples taken from the primary, secondary and filtered secondary terminals of the modeled CCVT. To provide a more thorough study, three different transient detection methods available in the literature were used to implement the analyzed fault location method. The obtained results indicate that the estimated fault locations are directly affected by the CCVT and CCVT+anti-aliasing filter frequency responses, resulting in a better performance of the fault location algorithm when the secondary voltage high frequency components are amplified.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/8167-
dc.date.accessioned2019-10-17T10:18:58Z-
dc.date.available2019-10-17-
dc.date.available2019-10-17T10:18:58Z-
dc.typeDissertaçãopt_BR
dc.subjectOndas Viajantes-
dc.subjectTransformadores de Potencial Capacitivos (TPC)-
dc.subjectLocalização de Faltas-
dc.subjectDetecção de Faltas-
dc.subjectTransitórios Eletromagnéticos-
dc.subjectFiltros Anti-aliasing-
dc.subjectAlternative Transients Program (ATP)-
dc.subjectTraveling Waves-
dc.subjectCapacitive Potential Transformers (TPC)-
dc.subjectFault Location-
dc.subjectFault Detection-
dc.subjectElectromagnetic Transients-
dc.subjectAnti-aliasing filters-
dc.subjectAlternative Transients Program (ATP)-
dc.rightsAcesso Abertopt_BR
dc.creatorREIS, Raphael Leite de Andrade.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeInfluence of capacitive potential transformers and anti-aliasing filters on fault location methods based on traveling wave theory.pt_BR
dc.identifier.citationREIS, Raphael Leite de Andrade. Influência de transformadores de potencial capacitivos e filtros anti-aliasing sobre métodos de localização de faltas baseados na teoria de ondas viajantes. 2015. 74f. (Dissertaçãoaaaaa0de Mestrado em Engenharia Elétrica, Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Campina Grande - Paraíba - Brasil, 2015.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
RAPHAEL LEITE DE ANDRADE REIS - DISSERTAÇÃO PPGEE 2015.pdfRaphael Leite de Andrade Reis - Dissertação PPGEE 20151.97 MBAdobe PDFView/Open