Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9367
Full metadata record
DC FieldValueLanguage
dc.creator.IDBENTO, A. A. M.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/1129596113585622pt_BR
dc.contributor.advisor1SILVA, Edison Roberto Cabral da.-
dc.contributor.advisor1IDSILVA, E. R. C.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/7577873305205472pt_BR
dc.contributor.referee1ANTUNES, Fernando Luiz Marcelo.-
dc.contributor.referee2JACOBINA, Cursino Brandão.-
dc.contributor.referee3OLIVEIRA, Talvanes Meneses.-
dc.description.resumoNeste trabalho é, inicialmente, apresentada uma classificação básica das soluções ativas para controle de fator de potência monofásico com corrente de linha senoidal. Em seguida, são apresentados os aspectos gerais das principais técnicas de controle empregadas nestas soluções usando o conversor boost. Na seqüência, é feito um estudo com o objetivo de se obter uma sistematização para as técnicas de controle de carga, que operam no modo de condução descontínua (MCD) e no modo de condução contínua (MCC) tanto para controle de corrente média quanto instantânea. Estas técnicas apresentam várias vantagens: a não necessidade de ter de investigar a natureza pulsante e não-linear do conversor, não há necessidade de amostra (sensor) de tensão de linha, nem multiplicadores analógicos, além de conseguir zerar o erro de corrente em apenas um ciclo de chaveamento. Uma nova técnica de controle de carga denominada Controle de Carga com modulação em freqüência (CCFM) é proposta para melhorar a distorção harmônica total (DHT) de um conversor boost intercalado com divisor capacitivo (BIC), existente na literatura. Resultados de simulação e experimentais mostraram um desempenho bastante satisfatório para esta técnica. Dois novos conversores CA-CA integrados são concebidos a partir do conversor boost intercalado analisado com controle de carga FM. Tais conversores apresentaram alto fator de potência e baixa DHT com resposta de saída rápida.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.titleEstudo das técnicas de controle de carga em conversores monofásicos para correção de fator de potência.pt_BR
dc.date.issued2005-02-
dc.description.abstractIn this dissertation, a simplified classification of active solutions for singlephase power factor (PF) correction circuits with sinusoidal line current is given first. Next, a review of general aspects of PF control strategies used with unidirectional boost converter is carried out. Then, a systematic study of the charge control technique is proposed for both discontinuous conduction mode (DCM) and continuous conduction mode (CCM) by considering either peak or average current control. The charge control has several advantages: it is independent of the pulsating or non-linear characteristic of the converter, does not need to template the line current thus eliminating multipliers, and allows making zero the current error in just one switching period. Also, a new technique here named Frequency Modulation Charge Control (FMCC) is introduced in order to improve the line current Total Harmonic Distortion (THD) of an interleaved boost with capacitance midpoint connection (IBC) converter already existent in the technical literature. Simulated and experimental results are reported showing that the application of the FMCC technique results in a satisfactory performance. In addition, two new integrated AC to AC converters are conceived from the IBC converter, which present high power factor, low THD, and fast response.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9367-
dc.date.accessioned2019-11-21T13:41:00Z-
dc.date.available2019-11-21-
dc.date.available2019-11-21T13:41:00Z-
dc.typeDissertaçãopt_BR
dc.subjectControle de Carga-
dc.subjectConversores Monofásicos-
dc.subjectCorreção de Fator de Potência-
dc.subjectCorrente de Linha Senoidal-
dc.subjectConversor Boost-
dc.subjectControle de Carga-
dc.subjectModo de Condução Descontínua (MCD)-
dc.subjectModo de Condução Contínua (MCC)-
dc.subjectLoad Control-
dc.subjectSingle-phase converters-
dc.subjectPower Factor Correction-
dc.subjectSinusoidal Line Current-
dc.subjectBoost converter-
dc.subjectLoad Control-
dc.subjectDiscontinuous Driving Mode (MCD)-
dc.subjectContinuous Driving Mode (MCC)-
dc.rightsAcesso Abertopt_BR
dc.creatorBENTO, Aluisio Alves de Melo.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeStudy of load control techniques in single phase converters for power factor correction.pt_BR
dc.identifier.citationBENTO, Aluisio Alves de Melo. Estudo das técnicas de controle de carga em conversores monofásicos para correção de fator de potência. 2005. 127f. (Dissertação de Mestrado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2005.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
ALUISIO ALVES DE MELO BENTO - DISSERTAÇÃO PPGEE 2005.pdfAluisio Alves de Melo Bento - Dissertação PPGEE 20053.8 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.