Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9369
Title: Modelagem de transformadores de corrente e correção distorcidas no enrolamento secundário.
Other Titles: Modeling of distorted current and correction transformers in the secondary winding.
???metadata.dc.creator???: PEREIRA, Fagner de Araújo.
???metadata.dc.contributor.advisor1???: COSTA, Edson Guedes da.
GUERRA, Francisco das Chagas Fernandes.
???metadata.dc.contributor.referee1???: LUCIANO, Benedito Antonio.
???metadata.dc.contributor.referee2???: SOUZA, Benemar Alencar de.
Keywords: Transformadores de Corrente (TCs);Distorções em TCs;Proteção de Sistema Elétrico;Correntes Distorcidas;Enrolamento Secundário;Saturação;Tensão;Processamento da Energia;Current Transformers (TCs);Distortions in CTs;Electrical System Protection;Distorted Chains;Secondary Winding;Saturation;Voltage;Energy Processing
Issue Date: Mar-2012
Publisher: Universidade Federal de Campina Grande
Citation: PEREIRA, Fagner de Araújo. Modelagem de transformadores de corrente e correção distorcidas no enrolamento secundário. 2012. 84f. (Dissertação de Mestrado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2012.
???metadata.dc.description.resumo???: Neste trabalho de dissertação é apresentada uma nova técnica para a correção de correntes distorcidas no enrolamento secundário de transformadores de corrente (TCs) utilizados no serviço de proteção. Ao contrário dos métodos convencionais em que a corrente é integrada numericamente para cálculo do fluxo de enlace, esta técnica é baseada na integração da tensão em um enrolamento terciário. Assim, a corrente de magnetização é determinada mediante a curva de saturação do núcleo e somada à corrente secundária distorcida, de modo a se obter uma reprodução fiel da onda de corrente primária. Outro aspecto inovador consiste no fato de que o fluxo residual no núcleo é determinado pela detecção do nível da corrente secundária e integração analógica da tensão no enrolamento terciário, desde o regime pré-falta até cerca de 1/6 de ciclo de tensão de 60 Hz após a ocorrência do defeito.
Abstract: In this dissertation work is presented a new technique for the correction of distorted currents in the secondary winding of current transformers (CTs) used for the protection service. Unlike conventional methods in which the current is integrated numerically to calculate the flow loop, this technique is based on integrating the voltage across a tertiary winding. Thus, the magnetizing current is determined by the saturation curve of the core and added to the secondary current distorted so as to obtain a faithful reproduction of the primary current waveform. Another innovative aspect is the fact that the residual flux in the core is determined by detecting the level of secondary current and integration of the analog voltage at the tertiary winding, since the system prefault to about 1/6 cycle voltage of 60 Hz after occurrence of the fault.
Keywords: Transformadores de Corrente (TCs)
Distorções em TCs
Proteção de Sistema Elétrico
Correntes Distorcidas
Enrolamento Secundário
Saturação
Tensão
Processamento da Energia
Current Transformers (TCs)
Distortions in CTs
Electrical System Protection
Distorted Chains
Secondary Winding
Saturation
Voltage
Energy Processing
???metadata.dc.subject.cnpq???: Engenharia Elétrica
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9369
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
FAGNER DE ARAUJO PEREIRA - DISSERTAÇÃO PPGEE 2012.pdf Fagner de Araújo Pereira - Dissertação PPGEE 20122.04 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.