Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9429
Full metadata record
DC FieldValueLanguage
dc.creator.IDFABRÍCIO, E. L. L.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/0577723750494758pt_BR
dc.contributor.advisor1JACOBINA, Cursino Brandão.-
dc.contributor.advisor1SANTOS JÚNIOR, Euzeli Cipriano dos.-
dc.contributor.advisor1IDJACOBINA, C. B.pt_BR
dc.contributor.advisor1IDSANTOS JÚNIOR, E. C.-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/0261885352003041pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/6627811177270508-
dc.contributor.referee1CORRÊA, Maurício Beltrão Rossiter.-
dc.contributor.referee2OLIVEIRA, Alexandre Cunha.-
dc.contributor.referee3ROCHA, Nady.-
dc.description.resumoA utilização de filtros ativos de potência (FAP) paralelos é a solução, mais empregada, para melhorar a qualidade de energia de sistemas. São compensadas, por esses filtros, harmônicas de corrente e reativos demandadas por cargas não lineares. Neste trabalho são estudadas associações de FAPs paralelos a três e quatro fios e propostas duas "filosofias" de controle. Essas tem como objetivo, além de compensar reativos e harmônicas de corrente, impor a divisão do fluxo de potência igualmente entre os filtros ou a divisão da função de compensação, onde um dos filtros compensará apenas as componentes reativas e o outro filtro compensará as componentes harmônicas. Para cada topologia estudada são abordadas os seguintes aspectos: (i) modelagem dinâmica da configuração; (ii) estratégia PWM e (iii) estratégia de controle. Será feito um estudo comparativo, entre as topologias convencionais e as topologias compostas por associação, das distorções harmônicas da corrente da rede elétrica e das perdas do sistema. As topologias, compostas por dois FAPs, permitem reduzir: as distorções da corrente da rede de alimentação, as perdas de alta frequência nos capacitores do barramento CC e as perdas nos semicondutores (IGBTs) em comparação às topologias convencionais nas mesmas condições de operação. As topologias são validadas apresentando-se os resultados de simulação e experimentais.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica-
dc.titleAssociação de filtros ativos de potência paralelos em sistemas a três e quatro fios.pt_BR
dc.advisor1Active Power Filter.-
dc.date.issued2011-03-03-
dc.description.abstractParallel active power filter (APF) is the solution more employed to improve the power system quality. Harmonics of the load current emitted by nonlinear loads are compensated by those lters. In this work are studied parallel association of APFs with three and four wires, in which are proposed two control philosophies for compensation of those harmonics. The rst strategy requires the power ow division equally between both lters, while the second established the division of compensation, where one lter compensate only the reactive and the other one compensate the harmonics components. For each topology studied will be addressed the following aspect: (i) modeling dynamics of the con guration; (ii) PWM strategy and (iii) control approach. A comparative study will be done in terms of harmonic distortions of the grid and power converter losses, as well; the conventional and the studied systems are employed in this comparison. The topologies composed of two APFs can reduce: the distortion of the grid, the high frequency losses in the dc-link, and the losses in semiconductor (IGBTs) devices, all compared to the conventional topology under the same conditions. The con gurations are validated by presenting the results of simulation and experimental.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9429-
dc.date.accessioned2019-11-22T18:52:02Z-
dc.date.available2019-11-22-
dc.date.available2019-11-22T18:52:02Z-
dc.typeDissertaçãopt_BR
dc.subjectConversores Elétricos-
dc.subjectQualidade de Energia-
dc.subjectFiltro Ativo de Potência-
dc.subjectCargas não Lineares-
dc.subjectDistorção Harmônica-
dc.subjectPerdas-
dc.subjectFiltros Ativos de Potência Paralelos-
dc.subjectSistemas a Três e Quatro Fios-
dc.subjectElectrical Converters-
dc.subjectPower Quality-
dc.subjectActive Power Filter.Non-linear-
dc.subjectNon-linear Loads.-
dc.subjectHarmonic Distortion.-
dc.subjectLosses.-
dc.subjectParallel Power Active Filters-
dc.subjectThree and Four Wire Systems-
dc.rightsAcesso Abertopt_BR
dc.creatorFABRÍCIO, Edgard Luiz Lopes.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeAssociation of parallel active power filters in three- and four-wire systems.pt_BR
dc.identifier.citationFABRÍCIO, Edgard Luiz Lopes. Associação de filtros ativos de potência paralelos em sistemas a três e quatro fios. 2011. 173f. (Dissertação de Mestrado em Engenharia Elétrica), Curso de Pós-Graduação em Engenharia Elétrica, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba – Campus II - Campina Grande - PB - Brasil, 2011.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
EDGARD LUIZ LOPES FABRÍCIO - DISSERTAÇÃO PPGEE 2011.pdfEdgard Luiz Lopes Fabrício - Dissertação PPGEE 20117.3 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.