Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9431
Full metadata record
DC FieldValueLanguage
dc.creator.IDGOMES, L. V.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/9663603094783048pt_BR
dc.contributor.advisor1COSTA, Edson Guedes da.
dc.contributor.advisor1IDCOSTA, E. G.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3930289115658143pt_BR
dc.contributor.referee1SOUZA, Benemar Alencar de.
dc.contributor.referee2LIRA, José Gutembergue de Assis.
dc.description.resumoUm fator importante na qualidade da energia do sistema elétrico é o sistema de aterramento. A maioria dos equipamentos de uma subestação utiliza a conexão de terra como referência para todas as outras tensões operacionais. Do ponto de vista da proteção, o objetivo de uma malha de aterramento é proporcionar uma superfície equipotencial no solo. Essa malha deve garantir que,quando uma corrente circular pelo aterramento, seja ela proveniente de uma falta ou de uma descarga atmosférica, não aparecerá diferenças de potencial entre diferentes pontos da subestação. Os sistemas de aterramento de subestações exigem uma avaliação periódica devido não só ao envelhecimento das malhas de terra como também aos problemas de corrosão, além dos desgastes devido à ocorrência de surtos elétricos. Essa avaliação deve ser feita com a subestação energizada, pois o desligamento das mesmas traria transtornos aos consumidores. Neste trabalho é apresentado um método de diagnóstico em malha de aterramento de subestações energizadas, que visa, por meio do mapeamento das tensões superficiais do solo (parte interna e externa da malha de aterramento) da subestação, identificar a localização de possíveis falhas (zonas de altas resistividades ou de desgaste/descontinuidade) na malha. Para isso, desenvolveu-se um sistema eletrônico embarcado capaz de medir diversos pontos de potenciais superficiais distribuídos ao longo da malha de aterramento. O sistema também é capaz de evidenciar o comportamento dos potenciais na superfície do solo, tanto em condições de regime permanente como também na ocorrência de um curto-circuito, por meio do processamento dos dados medidos via rotina computacional que exterioriza estes resultados por meio de gráficos bidimensionais (2D). As medições são realizadas na frequência industrial utilizando a corrente de desequilíbrio (desbalanço) do transformador como referência para a elevação do potencial do solo.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica
dc.titleSistema eletrônico embarcado para diagnóstico das condições de aterramento de subestações energizadas.pt_BR
dc.date.issued2012-08-31
dc.description.abstractAn important factor in the quality of electric power system is the Grounding System. Most equipment uses a substation ground connection as a reference for all other operating voltages. In protection, the objective of a grounding grid is to provide an equipotential surface in soil that will ensure that when a current circulating through the ground either from a fault or a lightning strike will not show differences in potential between specific substation points. The substation grounding systems require a periodic evaluation not only due to aging of ground loops, corrosion problems, apart from wear due to the occurrence of power surges. As the conditions to turn off the power substation increase in difficulty to pass, so increases the need to seek viable measurements alternatives, giving preference to methods of measurement of energized substation. On this paper is presented the development of a diagnosis in ground grid substation energized, which aims through the mapping of the surface tension of the soil (inside and outside the ground grid) substation, identifying the location of possible faults (e.g. zones of high ohmic resistance, corrosion, discontinuity) in the grid. It was developed an embedded electronic system capable of measure and to process several surface voltages distributed throughout the grounding grid. The system is also able to enhance behavior of the potential the soil surface, both in steady state conditions or in the occurrence of a short circuit, by processing the measured data via computer routine that exteriorize these results by two-dimensional graphics (2D). This evaluation must be done with the substation in working, where the current imbalance (unbalance) of the transformer is done reference to the rise of the ground potential.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9431
dc.date.accessioned2019-11-22T19:53:22Z
dc.date.available2019-11-22
dc.date.available2019-11-22T19:53:22Z
dc.typeDissertaçãopt_BR
dc.subjectSistema Eletrônico Embarcado
dc.subjectSistema de Aterramento
dc.subjectPotenciais de Superfície
dc.subjectSistemas Embarcados
dc.subjectDiagnóstico de Malha de Aterramento
dc.subjectMétodo das Diferenças Finitas
dc.subjectSubestações Energizadas
dc.subjectEmbedded Electronic System
dc.subjectGrounding System
dc.subjectSurface Potentials
dc.subjectEmbedded systems
dc.subjectGrounding Diagnosis
dc.subjectFinite Difference Method
dc.subjectEnergized Substations
dc.rightsAcesso Abertopt_BR
dc.creatorGOMES, Luana de Vasconcelos.
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeEmbedded electronic system for diagnosing grounding conditions of energized substations.pt_BR
dc.identifier.citationGOMES, Luana de Vasconcelos. Sistema eletrônico embarcado para diagnóstico das condições de aterramento de subestações energizadas. 2012. 58f. (Dissertação de Mestrado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2012. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9431pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
LUANA DE VASCONCELOS GOMES - DISSERTAÇÃO PPGEE 2012.pdfLuana de Vasconcelos Gomes- Dissertação PPGEE 20121.49 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.