Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9533
Full metadata record
DC FieldValueLanguage
dc.creator.IDCAVALCANTE JÚNIOR, J. Mpt_BR
dc.creator.Latteshttp://lattes.cnpq.br/3351376781364559pt_BR
dc.contributor.advisor1COSTA, Edson Guedes da.-
dc.contributor.advisor1IDCOSTA, E. G.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3930289115658143pt_BR
dc.contributor.advisor2ASSIS, Francisco Marcos de.-
dc.contributor.advisor2IDASSIS, F. M.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/2368523362272656pt_BR
dc.contributor.referee1SOUZA, Benemar Alencar de.-
dc.contributor.referee2DANTAS, Karcius Marcellus Colaço.-
dc.description.resumoEsta dissertação avalia a coordenação de isolamento de três seccionadores, considerando surtos de impulsos de manobra para sistemas elétricos com tensões nominais acima de 300 kV e surtos de impulsos atmosféricos para tensões abaixo de 300 kV. A partir de ensaios de seccionadores isolados a ar, realizados em laboratórios de extra-alta tensão, são coletados dados para a verificação da coordenação de isolamento com distâncias diferentes de open-gap e a distância de arco a seco no isolador, o que varia os valores de tensão disruptiva entre contatos e fase-terra, respectivamente. Uma análise estatística então é feita, com base nas curvas de distribuição normal de valores, tomando como base o método up and down com valores de tensão de ruptura de cinquenta por cento das tensões de impulso (U50%) e a dispersão dos valores medidos ( ). Adicionalmente, uma análise minuciosa dos resultados nos revela as condições nas quais não se consegue garantir a coordenação de isolamento do seccionador. Com base nesta análise, propõem-se estudos laboratoriais mais detalhados e indica-se a necessidade de inclusão de ensaios de tipo que comprovem a coordenação de isolamento do seccionador nos testes dielétricos das normas técnicas.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica-
dc.titleUma análise estatística da coordenação de isolamento em seccionadores de alta e extra-alta tensão.pt_BR
dc.date.issued2015-05-13-
dc.description.abstractThis dissertation evaluates the insulation coordination of three disconnectors isolated by air, with respect to switching surges for electrical systems with rated voltages above 300 kV, and atmospheric surges for voltages below 300 kV. From assay disconnectors isolated by air, in extra-high-voltage laboratories, data is collected for checking insulation coordination on the electrical distances of "Open-Gap" and dry arc distance, on the insulator, which varies the breakdown voltage values between contacts and fase-to-ground, respectively. Then the statistical analysis is performed on the normal distribution curve values, based on the method "up and down", on breakdown voltage values of the fifty percent of impulse voltages (U50%) and the dispersion of the measured values – standard deviation ( ). Thereafter, it is taken to analyze the results, obtaining the conditions for which, it may ensure the insulation coordination of the disconnector. Based on this analysis, it is proposed to more detailed laboratory studies and indicates the inclusion of dielectric tests proving the insulation coordination of the disconnector in the type testing of the Brazilian technical standard.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9533-
dc.date.accessioned2019-11-26T13:37:07Z-
dc.date.available2019-11-26-
dc.date.available2019-11-26T13:37:07Z-
dc.typeDissertaçãopt_BR
dc.subjectCoordenação de Isolamento-
dc.subjectSeccionadores-
dc.subjectEnsaios de Tipo-
dc.subjectIsolamento Elétrico-
dc.subjectSuportabilidade a Impulso Atmosférico-
dc.subjectSuportabilidade a Impulso de Manobra a Seco-
dc.subjectSuportabilidade a Impulso de Manobra sob Chuva-
dc.subjectIsolation Coordination-
dc.subjectDisconnectors-
dc.subjectType Tests-
dc.subjectElectrical Insulation-
dc.subjectSupport for Atmospheric Impulse-
dc.subjectSupport for Dry Maneuver Boost-
dc.subjectBearing Impulse Support in Rain-
dc.rightsAcesso Abertopt_BR
dc.creatorCAVALCANTE JÚNIOR, José Messias.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeA statistical analysis of insulation coordination in high and extra high voltage disconnectors.pt_BR
dc.identifier.citationCAVALCANTE JÚNIOR, José Messias. Uma análise estatística da coordenação de isolamento em seccionadores de alta e extra-alta tensão. 2015. 88f. (Dissertação) Mestrado em Engenharia Elétrica, Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande – Campina Grande - Paraíba - Brasil, 2015.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
JOSÉ MESSIAS CAVALCANTE JUNIOR - DISSERTAÇÃO PPGEE 2015.pdfJosé Messias Cavalcante Júnior - Dissertação PPGEE 20151.57 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.