Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9535
Full metadata record
DC FieldValueLanguage
dc.creator.IDARAUJO, D. B.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/4533756082631526pt_BR
dc.contributor.advisor1FREIRE, Raimundo Carlos Silvério.-
dc.contributor.advisor1IDFREIRE, R. C. S.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4016576596215504pt_BR
dc.contributor.advisor2LOPES, Waslon Terllizzie Araújo.-
dc.contributor.referee1NEVES, Washington Luiz Araújo.-
dc.contributor.referee2FERREIRA, Tarso Vilela.-
dc.description.resumoO isolamento elétrico é uma das partes mais importantes dos equipamentos elétrico. Seu objetivo é manter separadas as partes que se encontram entre diferentes potenciais, para que o seu funcionamento ocorra normalmente. Desta forma a integridade dos isolamentos é essencial para o bom funcionamento do equipamento e, no caso de uma falha do isolamento, danos podem ser causados ao mesmo, aos demais equipamentos que compõem o sistema e também às pessoas, além de poder interromper o fornecimento de energia elétrica, ocasionando em multas aplicadas por órgãos reguladores. As empresas do setor elétrico possuem interesse no bom funcionamento de seus equipamentos, e uma das formas de averiguar o bom funcionamento é por meio da verificação da integridade dos isolamentos elétricos, que pode ser realizada por meio da medição dos seus níveis de descargas parciais. Entretanto, estas medições são de difícil execução na maioria dos equipamentos elétricos, devido aos baixos níveis de intensidade das descargas, além de ruídos provenientes de diversas fontes, tais como emissões eletromagnéticas e manobras do sistema elétrico. Neste trabalho, um método de filtragem digital de sinais baseado na Transformada Wavelet é utilizado para realizar a atenuação dos ruídos presentes em sinais de descargas parciais medidos em laboratório. A partir dos resultados experimentais obtidos, verificou-se, por meio da visualização das formas de onda resultantes, uma redução considerável do ruído inerente às medições de descargas parciais. A filtragem deste ruído permite que uma futura quantificação do nível de descargas possa ser realizada, fazendo com que um diagnóstico do isolamento elétrico de um equipamento possa ser realizado, permitindo tomadas de decisão acerca de operação do equipamento, como possíveis realizações de manutenções para que os equipamentos possam operar de forma mais confiável.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica-
dc.titleAplicação da transformada wavelet à filtragem de sinais de descargas parciais.pt_BR
dc.date.issued2012-12-21-
dc.description.abstractThe electrical insulation is one of the most important parts of electrical equipment, which objective is to keep separate the different potential parts to guarantee the correct operation of the equipment. Thus, the integrity of those electrical insulations is essential for the correct operation of the equipment, and, in the case of failure, damage is caused to the equipment, to the others that compose the electrical system, people close to the installation and damage to the company’s image. Failures in the electrical systems can cause the interruption of the electrical energy supply, generating very high fines applied by regulatory agencies. The electric companies have interest on the correct operation of their equipment, and a way to verify that can be the verification of the integrity of the electrical insulation by measuring its partial discharge level. However, those measurements are very hard to be made in the great part of electrical equipment due to the low intensity level of the discharges, in addition to the from various sources such as electromagnetic emissions, system switching among others. In this work, a digital filtering method based on Wavelet Transform is used to perform the attenuation of noise in real partial discharge signals measured in laboratory. From the experimental results, it’s verified by visualizing the resultant waveforms a considerably attenuation of noise present in partial discharges. The noise filtering allows a future partial discharge quantification, making possible to know the integrity of the equipment insulation and also to make decisions about the operation of the equipment such as maintenances for the correct and more trustable operation of the equipment.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9535-
dc.date.accessioned2019-11-26T13:48:48Z-
dc.date.available2019-11-26-
dc.date.available2019-11-26T13:48:48Z-
dc.typeDissertaçãopt_BR
dc.subjectDescargas Parciais-
dc.subjectTransformada Wavelet-
dc.subjectIsolamento Elétrico-
dc.subjectMétodos de Atenuação de Ruído de Sinais de DP-
dc.subjectAnálise Multiresolução-
dc.subjectLocalização no Tempo-Frequencia-
dc.subjectPartial Discharges-
dc.subjectWavelet Transform-
dc.subjectElectrical Insulation-
dc.subjectDP Signal Noise Attenuation Methods-
dc.subjectMultiresolution Analysis-
dc.subjectTime-Frequency Location-
dc.rightsAcesso Abertopt_BR
dc.creatorARAUJO, Diego Buriti.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeApplication of the wavelet transform to the filtering of partial discharge signals.pt_BR
dc.identifier.citationARAUJO, Diego Buriti. Aplicação da transformada wavelet à filtragem de sinais de descargas parciais. 2012. 71f. (Dissertação) Mestrado em Engenharia Elétrica, Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Campina Grande - Paraíba - Brasil, 2012.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.