dc.contributor.advisor1NEVES, Washington Luiz Araújo.-
dc.contributor.advisor1FERNANDES JÚNIOR, Damásio.-
dc.contributor.advisor1IDNEVES, W. L. A.pt_BR
dc.contributor.advisor1IDFERNANDES JÚNIOR, D.-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3107104665517286pt_BR
dc.contributor.referee1FERNANDES, Alécio Barreto.-
dc.contributor.referee2SOUZA, Benemar Alencar de.-
dc.contributor.referee3MOTA, Wellington Santos.-
dc.description.resumoEste trabalho apresenta uma técnica para estimação paramétrica de equivalentes dependentes da frequência para aplicação em estudos de Tensão de Restabelecimento Transitória (TRT). Contribuições são apresentadas à representação das redes equivalentes, admitindo-se a extração de atributos das componentes harmônicas nas proximidades dos pontos de ressonância. Uma metodologia é proposta para aquisição precisa do espectro da rede externa real. Rotinas são implementadas para efetivar o cálculo dos elementos que compõem o modelo a parâmetros concentrados, proporcionando boa precisão. A validação é realizada nos domínios da frequência e do tempo, permitindo reduzir o grau de representação dos sistemas elétricos, garantindo boa confiabilidade às avaliações. Adicionalmente, visando minimizar as solicitações dielétricas impostas pela TRT, subsídios são propostos para dimensionar um dispositivo a base de varistores de Óxido de Zinco (ZnO) com a meta de limitar o valor de pico deste transitório. Testes de ensaio são reproduzidos digitalmente. Cenários de baixa frequência exigem maiores solicitações de energia ao dispositivo mitigador, no entanto, é possível caracterizar o número de pastilhas necessárias para reduzir a TRT a patamares seguros regidos pelas normas de fabricação dos equipamentos. Os resultados mostram que o dispositivo pode tornar permissivas operações qualificadas preliminarmente como proibitivas. O aporte financeiro normalmente destinado à aquisição de equipamentos de classe de tensão superior pode ser reduzido.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica-
dc.titleEquivalentes de redes elétricas e redução de tensão de restabelecimento transitória.pt_BR
dc.date.issued2010-03-23-
dc.description.abstractThis work presents a parameter estimation technique of Frequency Dependent Network Equivalents (FDNE) for application in Transient Recovery Voltage (TRV) studies. Contributions are presented to represent the network equivalent, assuming the attributes extraction of harmonic impedance components near the resonance points. A methodology is proposed for spectrum acquisition of the real external network. Routines are implemented to calculate the parameters that form a lumped model, providing good accuracy. The validation is performed in frequency and time domains, reducing electrical system modeling, ensuring reliability to assessments. Additionally, to minimize dielectrical stresses imposed by TRV, subsidies are offered to scale a device composed by Zinc Oxide (ZnO) varistors to limit TRV peak. Laboratory conditions are reproduced by digital tests. Low frequency cases require more energy from mitigating device, however, it is possible to characterize the number of discs needed to reduce TRV peak to acceptable levels specified by manufacturer standards. The results obtained in assessment presented good agreement, showing that the device can become permissive operations preliminarily qualified as unsafe. Financial support usually used to replace equipment by another with higher voltage class can be reduced.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9542-
dc.date.accessioned2019-11-26T14:36:13Z-
dc.date.available2019-11-26-
dc.date.available2019-11-26T14:36:13Z-
dc.typeDissertaçãopt_BR
dc.subjectCircuitos Equivalentes-
dc.subjectTRT-
dc.subjectEstimação de Parâmetros-
dc.subjectEquivalente Dependente da Frequência-
dc.subjectDispositivo de ZnO-
dc.subjectMitigação-
dc.subjectTransitórios Eletromagnéticos-
dc.subjectEquivalent Circuits-
dc.subjectParameter Estimation-
dc.subjectFrequency-Dependent Equivalent-
dc.subjectZnO Device-
dc.subjectMitigation-
dc.subjectElectromagnetic Transients-
dc.rightsAcesso Abertopt_BR
dc.creatorAZEVEDO, Wilker Victor da Silva.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeEquivalents of electrical networks and transient restoration voltage reduction.pt_BR
dc.identifier.citationAZEVÊDO, Wilker Victor da Silva. Equivalentes de redes elétricas e redução de tensão de restabelecimento transitória.. 2010. 91f. (Dissertação) Mestrado em Engenharia Elétrica, Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande – Campina Grande - Paraíba - Brasil, 2010.pt_BR