Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9572
Full metadata record
DC FieldValueLanguage
dc.creator.IDLOBO, P. C.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/6514989486185329pt_BR
dc.contributor.advisor1FREIRE, Raimundo Carlos Silvério.-
dc.contributor.advisor1IDFREIRE, R. C. S.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4016576596215504pt_BR
dc.contributor.referee1LUCIANO, Benedito Antonio.-
dc.contributor.referee2VILLANUEVA , Juan Moisés Maurício.-
dc.description.resumoPara a medição de grandezas físicas, como radiação, H, velocidade de fluidos, v e temperatura, Ta, existem configurações que se baseiam em sensores termorresistivos, utilizando o princípio da equivalência elétrica. Dentre as arquiteturas clássicas, que apresentam melhor resposta em frequência e utilizam este princípio, a mais comum é a que utiliza um sensor termorresistivo aquecido à uma temperatura constante. O sensor é aquecido por efeito Joule, à uma temperatura previamente determinada, e a variação da radiação térmica incidente, velocidade do fluido ou temperatura do meio é compensada variando-se o aquecimento elétrico devido à realimentação negativa utilizada, mantendo o sensor à uma temperatura quase constante. Neste trabalho é proposta uma arquitetura alternativa em que se faz constante a diferença de temperatura entre o sensor e o ambiente. Para ambas as configurações neste trabalho desenvolveram-se expressões e realizaram-se simulações para o sinal de saída em função da grandeza de entrada e da sensibilidade de arquiteturas com saídas analógicas e pulsadas (moduladas em duração de pulso - PWM), para sensores dos tipos PTC e NTC. Foram feitas comparações entre as arquiteturas, verificando-se que as arquiteturas com diferença de temperatura constante, saída analógica e com sensor termorresistivo do tipo PTC tinham melhor desempenho em relação à sensibilidade relativa, menor influência da grandeza interferente e maior influência da grandeza de entrada.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica-
dc.titleRadiômetro solar de equivalência elétrica com sensor aquecido à diferença de temperatura constante.pt_BR
dc.date.issued2015-03-
dc.description.abstractFor the measurement of physical quantities, such as radiation, H, velocity fluids, v, and temperature, Ta, there are settings based on thermoresistive sensors, which use the principle of electrical equivalence. Among the classic architectures, which have better frequency response and use this principle, the most common is the one that uses a thermoresistive sensor heated to a constant temperature. The sensor is heated by Joule effect to a previously stipulated temperature, and the variation of thermal radiation, temperature or flow velocity of the medium is compensated by varying the electric heating due to the negative feedback used, maintaining the sensor at an almost constant temperature. In this work it is proposed an alternative architecture that makes constant the temperature difference between the sensor and the environment. For both configurations, in this work, were developed expressions and simulations held for the output signal as a function of the input and the sensitivity of architecture with analog outputs and pulsed (modulated pulse duration - PWM) for sensors types of PTC and NTC. Comparisons were made between the architectures, verifying that architectures with constant temperature difference, analog output and thermoresistive sensor PTC had better performance with respect to the sensitivity, the less influence of interfering variable and the greater influence of input variable.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9572-
dc.date.accessioned2019-11-27T10:09:08Z-
dc.date.available2019-11-27-
dc.date.available2019-11-27T10:09:08Z-
dc.typeDissertaçãopt_BR
dc.subjectSensor Termorresistivo-
dc.subjectSensibilidade-
dc.subjectRadiação Solar-
dc.subjectTermistor-
dc.subjectRadiômetro Solar-
dc.subjectEquivalência Elétrica-
dc.subjectThermoresistive Sensor-
dc.subjectSensitivity-
dc.subjectSolar Radiation-
dc.subjectThermistor-
dc.subjectSolar Radiometer-
dc.subjectElectrical Equivalence-
dc.rightsAcesso Abertopt_BR
dc.creatorLOBO, Petrov Crescencio.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeSolar equivalence solar radiometer with heated sensor at constant temperature difference.pt_BR
dc.identifier.citationLOBO, Petrov Crescencio. Radiômetro solar de equivalência elétrica com sensor aquecido à diferença de temperatura constante. 2015. 106f. (Dissertação) Mestrado em Engenharia Elétrica, Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande – Campina Grande - Paraíba - Brasil, 2015.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
PETROV CRESCENCIO LOBO - DISSERTAÇÃO PPGEE 2015.pdfPetrov Crescencio Lobo - Dissertação PPGEE 20153.21 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.