Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9584
Full metadata record
DC FieldValueLanguage
dc.creator.IDFONSECA, N. S. S. M.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/6758262968199437pt_BR
dc.contributor.advisor1FREIRE, Raimundo Carlos Silvério.-
dc.contributor.advisor1IDFREIRE, R. C. S.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4016576596215504pt_BR
dc.contributor.advisor2FERREIRA, Tarso Vilela.-
dc.contributor.advisor2IDFERREIRA, T. V.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/9395719025602516pt_BR
dc.contributor.referee1GURJÃO, Edmar Candeia.-
dc.contributor.referee2LUCIANO, Benedito Antonio.-
dc.description.resumoNeste trabalho, é apresentado um sistema de aquisição de dados para transformadores trifásicos de distribuição. O sistema é capaz de medir e analisar formas de onda de tensão e corrente, calcular seus valores RMS, valores de harmônicas, distorção harmônica total, potência demandada, fator de potência e temperatura na carcaça do transformador. Os dados medidos são transferidos via rede sem fio, com protocolo ZigBee, para um computador pessoal, no qual um software de interface foi desenvolvido para concentrar e apresentar os dados na forma de valores numéricos e gráficos. O sistema de aquisição de dados utiliza um microcontrolador PIC18LF4520, um medidor de energia trifásico ADE7880 e um transceptor sem fio XBee-Pro. Os dados são medidos e enviados continuamente, permitindo assim que o usuário, a distância, monitore as variáveis elétricas e térmicas presentes no transformador de distribuição, e possa assim, avaliar as características da energia fornecida pelo equipamento. O sistema desenvolvido foi caracterizado e validado em laboratório com cargas lineares e não lineares, sendo posteriormente instalado em um transformador no Laboratório de Alta Tensão. No processo de validação, o sistema desenvolvido foi comparado com um Analisador de Qualidade de Energia Elétrica, e avaliados os desvios percentuais das medições realizadas dos dois equipamentos. O sistema desenvolvido apresentou desvios percentuais, em relação ao Analisador de Qualidade de Energia Elétrica, maiores nas medições dos sinais de corrente de cargas não lineares e menores nas medições dos sinais de tensão. O sistema pode ser utilizado não só para monitorar transformadores de distribuição, mas também qualquer outro equipamento que se adeque nos seus limites de corrente e tensão máximos.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica-
dc.titleSistema de aquisição de dados para monitoramento de transformadores de distribuição.pt_BR
dc.date.issued2015-03-
dc.description.abstractIn this work, a data acquisition system for three-phase transformers distribution is presented. The system is able to measure and analyze waveforms of voltage and current, calculate its RMS values, harmonic values, total harmonic distortion, demanded power, power factor and temperature in the transformer housing. The measured data is transferred via wireless network with ZigBee protocol, to a personal computer, where na software interface was developed to center and present the data in the form of numerical and graphical presentations. The data acquisition system uses a microcontroller PIC18LF4520, a three-phase power meter ADE7880 and a wireless transceiver XBee-Pro. The data is measured and sent continuously, allowing a user, in distance, monitor the electrical variables inherent in the distribution transformer, and can thus evaluate the energy characteristics provided by the equipment. The system was characterized, developed and validated in the laboratory with linear and nonlinear loads, and then installed in a transformer located at Laboratório de Alta Tensão. The developed system has presented percentage deviations relative to the Electric Power Quality Analyzer, higher in measurements of current signals of nonlinear loads and lower in measurements of voltage signals.The system can be used not only to monitor distribution transformers, but also any other equipment that fits in their limits of maximum current and voltages.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9584-
dc.date.accessioned2019-11-27T11:42:31Z-
dc.date.available2019-11-27-
dc.date.available2019-11-27T11:42:31Z-
dc.typeDissertaçãopt_BR
dc.subjectAquisição de Dados-
dc.subjectMonitoramento de Transformadores de Distribuição-
dc.subjectRede de Sensores sem Fio-
dc.subjectInstrumentação Eletrônica-
dc.subjectSistemas Embarcados-
dc.subjectProcessamento de Dados-
dc.subjectTransmissão de Dados-
dc.subjectData Acquisition-
dc.subjectMonitoring of Distribution Transformers-
dc.subjectWireless Sensor Network-
dc.subjectElectronic Instrumentation-
dc.subjectEmbedded Systems-
dc.subjectData Processing-
dc.subjectData Transmission-
dc.rightsAcesso Abertopt_BR
dc.creatorFONSÊCA, Newton Sávio Souza Marques da.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeData acquisition system for monitoring distribution transformers.pt_BR
dc.identifier.citationFONSÊCA, Newton Sávio Souza Marques da. Sistema de aquisição de dados para monitoramento de transformadores de distribuição. 2015. 115f. (Dissertação) Mestrado em Engenharia Elétrica, Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande – Campina Grande - Paraíba - Brasil, 2015.pt_BR
Appears in Collections:Mestrado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
NEWTON SÁVIO SOUZA MARQUES DA FONSÊCA - DISSERTAÇÃO PPGEE 2015.pdfNewton Sávio Souza Marques da Fonsêca - Dissertação PPGEE 20154.63 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.