dc.description.resumoEste trabalho apresenta uma técnica de estimação da poluição de isolamentos elétricos baseada no ruído ultrassônico emitido pelos mesmos, quando conectados a eletrodos energizados. A fim de atingir tal objetivo, foram realizados ensaios em laboratório, durante os quais os ruídos ultrassônicos foram digitalmente registrados para estudo posterior da melhor forma de processamento e extração de atributos. Como conseqüência deste estudo, obteve-se o algoritmo dos Vetores de Energia dos Centróides das Sub-bandas Espectrais (VECSE), o qual pode ser entendido como uma compressão espectral capaz de selecionar as bandas de frequência mais significativas do ruído. Em seguida, o áudio processado e transformado em VECSE constituiu uma base de dados que serviu para alimentar uma Rede Neural Artificial, capaz de distinguir com notável exatidão um VECSE oriundo de um isolamento mais poluído de um VECSE oriundo de um isolamento menos poluído. Por fim, para validar a técnica em campo, foram realizadas campanhas de medição na subestação Campina Grande 2, da Companhia Hidrelétrica do São Francisco. Durante estas campanhas se registrou ruído ultrassônico oriundo de vários equipamentos elétricos expostos a vários graus de poluição natural, e o processamento baseado em VECSE e Redes Neurais Artificial foi novamente aplicado. Como resultado, obtiveram-se taxas de acertos geralmente acima de 80% por parte da Rede Neural Artificial.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica-
dc.titleEstimação inteligente da poluição de isolamentos elétricos baseada nos VECSE do ruído ultrassônico.pt_BR
dc.date.issued2011-04-
dc.description.abstractThis work presents an electrical insulator pollution estimation technique based on the ultrasonic noise emitted by them, when connected to energized electrodes. In order to attain this objective, laboratory tests were performed, during which the ultrasonic noise was digitally registered for further study of the best processing and attribute extraction method. As a consequence of this study, the Spectral Sub-band Centroid Energy Vectors (SSCEV) algorithm was obtained, which can be understood as a spectral compression, capable of selecting the most significant frequency bands of the noise. Afterwards, the processed audio, changed into SSCEV, constituted a database which was fed to an Artificial Neural Network, capable of distinguishing with remarkable precision a SSCEV from a polluted insulator from a SSCEV from a less polluted insulator. Finally, in order to validate the technique in the field, measurement campaigns were performed in the substation Campina Grande II, of the São Francisco Hydroelectric Company. During these campaigns, ultrasonic noise from several electrical equipments, exposed to different natural pollution degrees, was obtained, and the processing, based on SSCEV and Artificial Neural Network was once again applied. As a result, success rates of over 80% were generally obtained by the Artificial Neural Network.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9600-
dc.date.accessioned2019-11-27T13:54:12Z-
dc.date.available2019-11-27-
dc.date.available2019-11-27T13:54:12Z-
dc.typeTesept_BR
dc.subjectIsolamentos Elétricos-
dc.subjectEstimação Inteligente da Poluição-
dc.subjectCompressão Espectral-
dc.subjectVetores de Energia-
dc.subjectCentróides das Sub-bandas Espectrais-
dc.subjectUltrassom-
dc.subjectRedes Neurais Artificiais-
dc.subjectRuído Ultrassônico-
dc.subjectElectrical Insulation-
dc.subjectIntelligent Pollution Estimation-
dc.subjectSpectral Compression-
dc.subjectEnergy Vectors-
dc.subjectCentroids of Spectral Sub-bands-
dc.subjectUltrasound-
dc.subjectArtificial Neural Networks-
dc.subjectUltrasonic Noise-
dc.rightsAcesso Abertopt_BR
dc.creatorFERREIRA, Tarso Vilela.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeIntelligent estimation of electrical insulation pollution based on VECSE of ultrasonic noise.pt_BR
dc.identifier.citationFERREIRA, Tarso Vilela. Estimação inteligente da poluição de isolamentos elétricos baseada nos VECSE do ruído ultrassônico. 2011. 134f. (Tese de Doutorado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2011.pt_BR
Appears in Collections:Doutorado em Engenharia Elétrica.

Files in This Item:
File Description SizeFormat 
TARSO VILELA FERREIRA - TESE PPGEE 2011.pdfTarso Vilela Ferreira - Tese PPGEE 20116.07 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.