dc.description.resumo O presente trabalho tem como principal objetivo conhecer a qualidade da água que esta sendo consumida pela população do Hospital Universitário Alcides Carneiro (HUAC) localizado na cidade de Campina Grande - PB, com o proposito de conhecer o sistema de distribuição de água predial daquele hospital, visando através da monitoração de indicadores sentinelas sugerir a elaboração e implantação de uma piano de manutenção para qualidade da água, procurando desta forma, manter um sistema distribuição com controle preventivo evitando consequentemente, possíveis disseminações de doenças relacionadas a água. O piano de manutenção devera atender aos padrões de potabilidade estabelecidos pela Portaria N° 518 de 25 de marco de 2004 do Ministério da Saúde e a Diretriz National do Piano de Amostragem da Vigilância em Saúde Ambiental relacionada a qualidade da água para consumo humano. Os resultados obtidos durante os sete meses de analise nos treze pontos de monitoração revelaram a vulnerabilidade do sistema de abastecimento do HUAC, em razão das baixas concentrações de cloro residual livre verificada na rede distribuição e nos reservatórios de acumulação e predominância das especies de cloro residual combinado. Outros fatores relacionados a manutenção do sistema predial como tempo de existência das tubulações e reservatórios, infiltrações, vazamentos e falta de limpeza adequada nos reservatórios também podem ter contribuído para a degradação da qualidade da água consumida pela população do hospital. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTAL pt_BR
dc.publisher.initials UFCG pt_BR
dc.title Avaliação da qualidade da água consumida em um hospital público da cidade de Campina Grande-PB. pt_BR
dc.date.issued 2010-03
dc.description.abstract The present work has as main objective to know the quality of water being consumed by the population of the University Hospital Alcides Carneiro (HUAC) in the city of Campina Grande - PB, in order to know the distribution system of water property that hospital, order by monitoring sentinel indicators suggest the development and implementation of a maintenance plan for water quality, thereby attempting to maintain a distribution system to control by avoiding therefore possible spread of diseases related to water. The maintenance plan must meet the standards of potability and established by Ordinance No. 518 of March 25, 2004 the Ministry of Health and National Planning Guidance Sampling Surveillance in Environmental Health-related quality of drinking water. The results obtained during the seven months of analysis in the thirteen monitoring points showed the vulnerability of the supply system of the HUAC, due to low concentrations of free residual chlorine found in the distribution network and reservoirs for the accumulation and the predominance of species of combined chlorine residual . Other factors related to the maintenance of the building as a time of existence of pipes and reservoirs, seepage, leakage and lack of proper cleaning the tanks may also have contributed to the degradation of the quality of water consumed by the population of the hospital. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10042
dc.date.accessioned 2019-12-10T12:21:12Z
dc.date.available 2019-12-10
dc.date.available 2019-12-10T12:21:12Z
dc.type Dissertação pt_BR
dc.subject Abastecimento de Água
dc.subject Qualidade da Água
dc.subject Indicadores Sentinelas
dc.subject Cloro Residual Combinado
dc.subject Portaria 518 (MS)
dc.subject Sistema de Abastecimento
dc.subject Controle de Qualidade
dc.subject Water Supply
dc.subject Water Quality
dc.subject Sentinel Indicators
dc.subject Combined Residual Chlorine
dc.subject Ordinance 518 (MS)
dc.subject Supply System
dc.subject Quality Control
dc.rights Acesso Aberto pt_BR
dc.creator BARBOSA, Flávia Lima.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Evaluation of the quality of water consumed in a public hospital in Campina Grande-PB. pt_BR
dc.identifier.citation BARBOSA, Flávia Lima. Avaliação da qualidade da água consumida em um hospital público da cidade de Campina Grande-PB. 2010. 104f. (Dissertação de Mestrado em Engenharia Civil e Ambiental), Programa de Pós-Graduação em Engenharia Civil e Ambiental, Universidade Federal de Campina Grande - Paraíba - Brasil, 2010. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10042 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta