dc.description.resumo |
O presente trabalho tem como principal objetivo conhecer a qualidade da água que esta sendo consumida pela população do Hospital Universitário Alcides Carneiro (HUAC) localizado na cidade de Campina Grande - PB, com o proposito de conhecer o sistema de distribuição de água predial daquele hospital, visando através da monitoração de indicadores sentinelas sugerir a elaboração e implantação de uma piano de manutenção para qualidade da água,
procurando desta forma, manter um sistema distribuição com controle preventivo evitando consequentemente, possíveis disseminações de doenças relacionadas a água. O piano de manutenção devera atender aos padrões de potabilidade estabelecidos pela Portaria N° 518 de 25 de marco de 2004 do Ministério da Saúde e a Diretriz National do Piano de Amostragem da Vigilância em Saúde Ambiental relacionada a qualidade da água para consumo humano.
Os resultados obtidos durante os sete meses de analise nos treze pontos de monitoração
revelaram a vulnerabilidade do sistema de abastecimento do HUAC, em razão das baixas
concentrações de cloro residual livre verificada na rede distribuição e nos reservatórios de acumulação e predominância das especies de cloro residual combinado. Outros fatores relacionados a manutenção do sistema predial como tempo de existência das tubulações e
reservatórios, infiltrações, vazamentos e falta de limpeza adequada nos reservatórios também
podem ter contribuído para a degradação da qualidade da água consumida pela população do hospital. |
pt_BR |
dc.publisher.country |
Brasil |
pt_BR |
dc.publisher.department |
Centro de Tecnologia e Recursos Naturais - CTRN |
pt_BR |
dc.publisher.program |
PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTAL |
pt_BR |
dc.publisher.initials |
UFCG |
pt_BR |
dc.title |
Avaliação da qualidade da água consumida em um hospital público da cidade de Campina Grande-PB. |
pt_BR |
dc.date.issued |
2010-03 |
|
dc.description.abstract |
The present work has as main objective to know the quality of water being consumed by the
population of the University Hospital Alcides Carneiro (HUAC) in the city of Campina
Grande - PB, in order to know the distribution system of water property that hospital, order by
monitoring sentinel indicators suggest the development and implementation of a maintenance
plan for water quality, thereby attempting to maintain a distribution system to control by
avoiding therefore possible spread of diseases related to water. The maintenance plan must
meet the standards of potability and established by Ordinance No. 518 of March 25, 2004 the
Ministry of Health and National Planning Guidance Sampling Surveillance in Environmental
Health-related quality of drinking water. The results obtained during the seven months of
analysis in the thirteen monitoring points showed the vulnerability of the supply system of the
HUAC, due to low concentrations of free residual chlorine found in the distribution network
and reservoirs for the accumulation and the predominance of species of combined chlorine
residual . Other factors related to the maintenance of the building as a time of existence of
pipes and reservoirs, seepage, leakage and lack of proper cleaning the tanks may also have
contributed to the degradation of the quality of water consumed by the population of the
hospital. |
pt_BR |
dc.identifier.uri |
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10042 |
|
dc.date.accessioned |
2019-12-10T12:21:12Z |
|
dc.date.available |
2019-12-10 |
|
dc.date.available |
2019-12-10T12:21:12Z |
|
dc.type |
Dissertação |
pt_BR |
dc.subject |
Abastecimento de Água |
|
dc.subject |
Qualidade da Água |
|
dc.subject |
Indicadores Sentinelas |
|
dc.subject |
Cloro Residual Combinado |
|
dc.subject |
Portaria 518 (MS) |
|
dc.subject |
Sistema de Abastecimento |
|
dc.subject |
Controle de Qualidade |
|
dc.subject |
Water Supply |
|
dc.subject |
Water Quality |
|
dc.subject |
Sentinel Indicators |
|
dc.subject |
Combined Residual Chlorine |
|
dc.subject |
Ordinance 518 (MS) |
|
dc.subject |
Supply System |
|
dc.subject |
Quality Control |
|
dc.rights |
Acesso Aberto |
pt_BR |
dc.creator |
BARBOSA, Flávia Lima. |
|
dc.publisher |
Universidade Federal de Campina Grande |
pt_BR |
dc.language |
por |
pt_BR |
dc.title.alternative |
Evaluation of the quality of water consumed in a public hospital in Campina Grande-PB. |
pt_BR |
dc.identifier.citation |
BARBOSA, Flávia Lima. Avaliação da qualidade da água consumida em um hospital público da cidade de Campina Grande-PB. 2010. 104f. (Dissertação de Mestrado em Engenharia Civil e Ambiental), Programa de Pós-Graduação em Engenharia Civil e Ambiental, Universidade Federal de Campina Grande - Paraíba - Brasil, 2010. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10042 |
pt_BR |