DSpace/Manakin Repository

Avaliação e comparação do desempenho de um sistema de membranas de micro/nano filtração com o sistema de osmose inversa para diferentes níveis de concentração de saia de águas salobras da comunidade de Uruçu em São João do Cariri-PB.

Mostrar registro simples

dc.creator.ID QUEIROZ, F. R. M. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/8997152772693829 pt_BR
dc.contributor.advisor1 FRANÇA, Kepler Borges.
dc.contributor.advisor1ID FRANÇA, K. B. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/3620576114544758 pt_BR
dc.contributor.referee1 BRANDÃO, Antônio Carlos.
dc.contributor.referee2 OLIVEIRA, Laercio Gomes de.
dc.description.resumo O processo de membranas no tratamento de água vem sendo uma das alternativas na produção de água potável para beneficiar as comunidades nas regiões Semi-árido do Nordeste brasileiro. O presente trabalho tem como objetivo estudar o desempenho de um sistema de tratamento de águas com membranas de microfiltração (MF) e nanofiltração (NF), visando avaliar seu potencial de dessalinização e comparar a qualidade do seu permeado com o do sistema de osmose inversa. O sistema contara com dois elementos de membranas, sendo um de nanofiltração modelo NF90 - 4040 da Dow Chemical Company - Filmtec, com área de 7,6 m2 e o outro por uma membrana de microfiltração na forma de fibras ocas com dimensão de 0,95 mm de diâmetro e 14 m2 de área, de capacidade de produção de 500 L/h e 250 L/h, respectivamente. O uso de um sistema de pre-tratamento bem escolhido e um elemento chave para evitar incrustações em nanofiltração. Entre as diferentes possibilidades para sistemas de pre-tratamento, microfiltração surge como a mais compátivel com a (NF). O estudo foi executado em oito partes com uma duração de 2 h para cada experimento em um intervalo de 10 em 10 min, coletando as amostras da alimentação, concentrado e permeado do sistema. A titulo de comparação do desempenho com o sistema de osmose inversa, foi escolhido uma água salobra de poço, com um TDS igual a 2479,7 mg/L, a qual vem sendo dessalinizada por um sistema de osmose inversa localiza na comunidade de Uruçu no município de São João do Cariri - PB. Os perfis de concentrações de sais do sistemas de micro - nanofiltração e de osmose inversa foi feita através das analises físico-químicas, obtendo em media uma taxa de rejeição de cálcio de 82,74% no permeado do sistema de micro - nanofiltração e para osmose inversa a taxa de rejeição de 99%. Observou-se que a limpeza química e uma das etapas de manutenção que procura manter a produção e a qualidade do permeado dentro dos padrões de qualidades. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Ciências e Tecnologia - CCT pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA QUÍMICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Química
dc.title Avaliação e comparação do desempenho de um sistema de membranas de micro/nano filtração com o sistema de osmose inversa para diferentes níveis de concentração de saia de águas salobras da comunidade de Uruçu em São João do Cariri-PB. pt_BR
dc.date.issued 2012-09
dc.description.abstract The membranes processing during water treatment has been one of the alternatives for production of drinkable water for the benefit of communities in semi-arid regions of Northeastern Brazil. The objective of this work is studying the performance of a system of water treatment with membranes of microfiltration (MF) and_nanofiltration (NF), in order to access their desalination potential and to compare their permeated quality with that of the reverse osmosis system. The system will contain two membranes elements, one of those is a Dow Chemical Company - Filmtec model NF90 - 4040 with an area of 7,6 m2, and the other is composed of a microfiltration membrane made of hollow fibers with measures of diameter 0,95 mm and area of 14 m2 .whose capacity of production are of 500 L/h and 250 L/h, respectively. The use of a well-chosen pre-treatment system is a key element to prevent incrustations in nanofiltration. Among the different possibilities of pre-treatment systems, microfiltration arises as the most compatible with (NF). The study was carried out in eight parts with a 2 h duration for each part at intervals of 10 minutes when were collected samples of the feeding, concentrated and permeated from the system. As an instance of comparison with the reverse osmosis system, a salty water well was chosen, with a 2479,7 mg/L TDS, has been being desalinized by a reverse osmosis system located at the village of Urucu, in Sao Joao do Cariri - PB. The salt concentration profiles of the micro - nanofiltration and reverse osmosis systems were done through physico-chemical analysis reaching an average rejection rate for calcium of 82,74% in the micro -nanofiltration system and a rejection rate of 99% for reverse osmosis. It was observed that the chemical purity is a maintenance step which is searched for keeping the quality and production of the permeated within the acceptable established standards. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10102
dc.date.accessioned 2019-12-11T13:50:27Z
dc.date.available 2019-12-11
dc.date.available 2019-12-11T13:50:27Z
dc.type Dissertação pt_BR
dc.subject Processos de Membrana
dc.subject Membrana de Microfiltração
dc.subject Membrana de Nanofiltração
dc.subject Água Salobra
dc.subject Osmose Inversa
dc.subject Tratamento de Águas
dc.subject Membrane Processes
dc.subject Microfiltration Membrane
dc.subject Nanofiltration Membrane
dc.subject Brackish Water
dc.subject Reverse Osmosis
dc.subject Water Treatment
dc.rights Acesso Aberto pt_BR
dc.creator QUEIROZ, Francisco Rubens Macedo de.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Evaluation and comparison of the performance of a micro / nano filtration membrane system with the reverse osmosis system for different brackish water skirt concentration levels of the uruçu community in São João do Cariri-PB. pt_BR
dc.identifier.citation QUEIROZ, Francisco Rubens de. Avaliação e comparação do desempenho de um sistema de membranas de micro/nano filtração com o sistema de osmose inversa para diferentes níveis de concentração de saia de águas salobras da comunidade de Uruçu em São João do Cariri-PB. 2012. 149 f. (Dissertação) Mestrado em Engenharia Química, Programa de Pós-graduação em Engenharia Química, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande - Campina Grande - Paraíba - Brasil, 2012. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10102 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta