dc.description.resumo |
A utilização de ligas de NiTi tratadas superficialmente, permite combinar as
características da liga metálica em estudo com as características do
revestimento a ser formado na superfície do material base. Neste trabalho
foram estudadas a cinética de corrosão e as características encontradas em
cada liga de NiTi com composição diferenciada para uma melhor abordagem
do problema, analisando não apenas as superfícies tratadas superficialmente,
como também aquelas que não sofreram nenhuma modificação. Com isso, o
comportamento eletroquímico das ligas metálicas de NiTi foi verificado em um
meio que se assemelha bastante as condições corpóreas. A partir de ensaios
eletroquímicos, foi possível a comparação dos resultados obtidos entre as ligas
metálicas em estudo. Alem dos métodos eletroquímicos empregados no estudo
da resistência a corrosão das ligas metálicas de NiTi, também foram utilizadas
métodos de analises na quantificação das modificações superficiais oriundas
dos tratamentos empregados. Foi observado ao longo deste trabalho a
resistência que os materiais a base de nitinol possuem, quando submetidos a
teste em solução de Hank's que se assemelha bastante ao sangue, como
também utilizando uma temperatura em torno de 37 °C que e normalmente a
temperatura encontrada no corpo humano e constata-se uma boa durabilidade
do material. Os testes utilizados na analise das modificações ocorridas na
superfície das amostras revelaram as mudanças causadas quando a superfície
passa por irradiações por feixe de laser de acordo com cada composição da
liga e os possíveis danos que isso pode acarretar no processo de degradação
do material. |
pt_BR |
dc.publisher.country |
Brasil |
pt_BR |
dc.publisher.department |
Centro de Ciências e Tecnologia - CCT |
pt_BR |
dc.publisher.program |
PÓS-GRADUAÇÃO EM ENGENHARIA QUÍMICA |
pt_BR |
dc.publisher.initials |
UFCG |
pt_BR |
dc.subject.cnpq |
Engenharia Química. |
|
dc.title |
Cinética de corrosão e caracterização microestrutural de materiais à base de ligas de NiTi para aplicação em stents cardiovasculares. |
pt_BR |
dc.date.issued |
2012-08-23 |
|
dc.description.abstract |
The use of NiTi alloys surface treated, allows to combine the characteristics of
the alloy in a study of the characteristics of the coating to be formed on the
surface of the base material. In this study the kinetics of corrosion and features
found in each NiTi alloy with different composition to better approach the
problem by analyzing not only superficially treated surfaces, as well as those
who experienced no change. Therefore, the electrochemical behavior of NiTi
alloys was verified in a way that closely resembles the bodily conditions. From
electrochemical tests, it was possible to compare the results between the alloys
under study. Besides the methods employed to study the electrochemical
corrosion resistance of alloys of NiTi, were also used assay methods in
quantification of surface modifications coming from the treatments. It was
observed throughout this work the resistance that the material to base nitinol
have, when subjected to test in a solution of Hank's that closely resembles the
blood, as well as using a temperature around 37 ° C which is normally the
temperature found in human body and it is observed a good durability of the
material. The tests used in the analysis of the changes occurring on the surface
of the samples revealed changes caused when the surface undergoes
irradiation by laser beam according to each alloy composition and the possible
damage that may result in degradation of the material. |
pt_BR |
dc.identifier.uri |
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10247 |
|
dc.date.accessioned |
2019-12-17T12:21:12Z |
|
dc.date.available |
2019-12-17 |
|
dc.date.available |
2019-12-17T12:21:12Z |
|
dc.type |
Dissertação |
pt_BR |
dc.subject |
Liga NiTi |
|
dc.subject |
Liga Memória de Forma |
|
dc.subject |
Cinética Eletroquímica |
|
dc.subject |
Biomateriais |
|
dc.subject |
Cinética de Corrosão |
|
dc.subject |
Stents Cardiovasculares |
|
dc.subject |
Emprego de Laser |
|
dc.subject |
Corrosão - Materiais Metálicos |
|
dc.subject |
NiTi Alloy |
|
dc.subject |
Connects Shape Memory |
|
dc.subject |
Electrochemical Kinetics |
|
dc.subject |
Biomaterials |
|
dc.subject |
Corrosion Kinetics |
|
dc.subject |
Cardiovascular Stents |
|
dc.subject |
Use of Laser. |
|
dc.subject |
Corrosion - Metallic Materials |
|
dc.rights |
Acesso Aberto |
pt_BR |
dc.creator |
OLIVEIRA, Cláudio Emanuel Silva. |
|
dc.publisher |
Universidade Federal de Campina Grande |
pt_BR |
dc.language |
por |
pt_BR |
dc.title.alternative |
Corrosion kinetics and microstructural characterization of NiTi alloy-based materials for application in cardiovascular stents. |
pt_BR |
dc.identifier.citation |
OLIVEIRA, Cláudio Emanuel Silva. Cinética de corrosão e caracterização microestrutural de materiais a base de ligas de NiTi para aplicação em stents cardiovasculares. 2012. 123f. (Dissertação de Mestrado em Engenharia Química), Programa de Pós-graduação em Engenharia Química, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande - Paraíba - Brasil, 2012. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10247 |
pt_BR |