dc.creator.ID |
BARBOSA, A. F. |
pt_BR |
dc.creator.Lattes |
http://lattes.cnpq.br/4012220886988503 |
pt_BR |
dc.contributor.advisor1 |
FREIRE, Raimundo Carlos Silvério. |
|
dc.contributor.advisor1 |
DEEP, Gurdip Singh. |
|
dc.contributor.advisor1ID |
FREIRE, R. C. S. |
pt_BR |
dc.contributor.advisor1ID |
DEEP, G. S. |
|
dc.contributor.advisor1Lattes |
http://lattes.cnpq.br/4016576596215504 |
pt_BR |
dc.contributor.advisor1Lattes |
http://lattes.cnpq.br/6322106621770962 |
|
dc.contributor.referee1 |
SILVA, José Felício da. |
|
dc.contributor.referee2 |
Fontgalland, Glauco. |
|
dc.description.resumo |
Um sistema que perrnite a monitorizacao da contracao utenna e do batimento cardiaco
fetal foi projetado e implementado. Parte importante desse sistema sao os sensores, os
quais atendem aos seguintes criterios: ser nao invasivo e proporcionar comodidade e
eonforto a gestante: Paraaquisicao da contracao uterina, inicialmente, investigou-se a
utilizacao de.,um, sensor capaciiiyo mediante teste em gestantes. Os resultados obtidos
rnostraram que o sensor capacitivo nao apresentava sensibilidade adequada a variacao
de pressao, Investiu-se na busca de um novo sensor que oferecesse urna melhor
sensibilidade, que ocorreu em duas etapas: uma relativa ao projeto e construcao da
estrutura mecanica e outra relativa ao projeto e montagem de um circuito eletronico. 0
principio de funcionamento do sensor desenvolvido e fazer variar uma indutancia,
quando ocorre uma contrafao uterina. Para aquisifao do batimento cardiaco fetal foi
utilizado um sensor integrante de um detector de batimento cardiaco, DF-4001 baseado
em-efeito Dopplen A-partirdQ^sinal obtido no detector foi projetado e implementado um
circuito eletronico que conta os pulsos de batimento e apresenta o resultado em um
mostrador de 7 segmentos. Para o armazenamento dos dados adquiridos pelos sensores
de contracao uterina e do batimento cardiaco fetal, desenvolveu-se um software para o
microcontrolador MC68HC11 realizar a medi9ao do periodo entre dois pulsos e
posteriormente foi ampliado para que o mesmo pudesse medir 10 periodos T, e obter
uma media das medi9oes. Decisoes sao tomadas no microcontrolador referentes aos
casos em que a taxa de batimento cardiaco fetal ou as contra9des uterinas estejam fora
dos padroes de normal idade, gerando sinais de alarme. |
pt_BR |
dc.publisher.country |
Brasil |
pt_BR |
dc.publisher.department |
Centro de Engenharia Elétrica e Informática - CEEI |
pt_BR |
dc.publisher.program |
PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA |
pt_BR |
dc.publisher.initials |
UFCG |
pt_BR |
dc.subject.cnpq |
Engenharia Elétrica |
|
dc.title |
Sistema de aquisição de dados para acompanhamento de gestantes em trabalho de parto. |
pt_BR |
dc.date.issued |
2003-03-28 |
|
dc.description.abstract |
A system that allows the monitoring of the uterine contraction and the fetal heart beat it was projected and implemented. Important parts of this system are the sensors, which
assist to the following criteria: to be not invasive and to provide comfort to the pregnant. For acquisition' of the; uterine-contraction, initially, the use of a sensor capacitive was investigated by.testing.it in the pregnant. The obtained results showed that the sensor capacitive didn't present appropriate sensibility to the pressure variation. It was invested in the search of a new one sensor that could offer a better sensibility, which happened in two stages: one relative to the project and construction of the mechanical structure and other relative one to the project and assembly of an electronic circuit. The beginning of
operation of the sensor developed is to do to vary an inductance, when an uterine contraction happens. For acquisition of the fetal heart beat a sensor in the detector of heart beat, DF-4001 was used based on Doppler effect. Starting from the sign obtained in the detector was projected' and implemented an electronic circuit that it counts the beat pulses and it presents the result in a display case of 7 segments. For the storage of the acquired data.for the sensor of uterine contraction and of the fetal heart beat, it was developed a software for the microcontrolador MC6SHC11 to accomplish the measurement of the period among two pulses and later it was enlarged so that the same could measure 10 periods T, and to obtain an average of the measurements. Decisions are made in the microcontrolador regarding the cases in that the tax of fetal heart beat or the uterine contractions are out of the normality patterns, generating alarm signs. |
|
dc.identifier.uri |
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10321 |
|
dc.date.accessioned |
2019-12-18T18:12:16Z |
|
dc.date.available |
2019-12-18 |
|
dc.date.available |
2019-12-18T18:12:16Z |
|
dc.type |
Dissertação |
pt_BR |
dc.subject |
Sistema de Aquisição de Dados |
|
dc.subject |
Aquisição de Sinais - Gestantes - Trabalho de Parto |
|
dc.subject |
Sensores |
|
dc.subject |
Sensor Capacitivo |
|
dc.subject |
Circuito Eletrônico |
|
dc.subject |
Armazenamento dos Dados |
|
dc.subject |
Microcontrolador |
|
dc.subject |
Data Acquisition System |
|
dc.subject |
Signal Acquisition - Pregnant Women - Labor |
|
dc.subject |
Sensors |
|
dc.subject |
Capacitive Sensor |
|
dc.subject |
Eletronic Circuit |
|
dc.subject |
Data Storage |
|
dc.subject |
Microcontroller |
|
dc.rights |
Acesso Aberto |
pt_BR |
dc.creator |
BARBOSA, Antenor Farias. |
|
dc.publisher |
Universidade Federal de Campina Grande |
pt_BR |
dc.language |
por |
pt_BR |
dc.title.alternative |
Data acquisition system for monitoring pregnant women in labor. |
pt_BR |
dc.identifier.citation |
BARBOSA, Antenor Farias. Sistema de aquisição de dados para acompanhamento de gestantes em trabalho de parto. 2003. 128f. (Dissertação de Mestrado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2003. |
pt_BR |