DSpace/Manakin Repository

Sistema de aquisição de dados para acompanhamento de gestantes em trabalho de parto.

Mostrar registro simples

dc.creator.ID BARBOSA, A. F. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/4012220886988503 pt_BR
dc.contributor.advisor1 FREIRE, Raimundo Carlos Silvério.
dc.contributor.advisor1 DEEP, Gurdip Singh.
dc.contributor.advisor1ID FREIRE, R. C. S. pt_BR
dc.contributor.advisor1ID DEEP, G. S.
dc.contributor.advisor1Lattes http://lattes.cnpq.br/4016576596215504 pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/6322106621770962
dc.contributor.referee1 SILVA, José Felício da.
dc.contributor.referee2 Fontgalland, Glauco.
dc.description.resumo Um sistema que perrnite a monitorizacao da contracao utenna e do batimento cardiaco fetal foi projetado e implementado. Parte importante desse sistema sao os sensores, os quais atendem aos seguintes criterios: ser nao invasivo e proporcionar comodidade e eonforto a gestante: Paraaquisicao da contracao uterina, inicialmente, investigou-se a utilizacao de.,um, sensor capaciiiyo mediante teste em gestantes. Os resultados obtidos rnostraram que o sensor capacitivo nao apresentava sensibilidade adequada a variacao de pressao, Investiu-se na busca de um novo sensor que oferecesse urna melhor sensibilidade, que ocorreu em duas etapas: uma relativa ao projeto e construcao da estrutura mecanica e outra relativa ao projeto e montagem de um circuito eletronico. 0 principio de funcionamento do sensor desenvolvido e fazer variar uma indutancia, quando ocorre uma contrafao uterina. Para aquisifao do batimento cardiaco fetal foi utilizado um sensor integrante de um detector de batimento cardiaco, DF-4001 baseado em-efeito Dopplen A-partirdQ^sinal obtido no detector foi projetado e implementado um circuito eletronico que conta os pulsos de batimento e apresenta o resultado em um mostrador de 7 segmentos. Para o armazenamento dos dados adquiridos pelos sensores de contracao uterina e do batimento cardiaco fetal, desenvolveu-se um software para o microcontrolador MC68HC11 realizar a medi9ao do periodo entre dois pulsos e posteriormente foi ampliado para que o mesmo pudesse medir 10 periodos T, e obter uma media das medi9oes. Decisoes sao tomadas no microcontrolador referentes aos casos em que a taxa de batimento cardiaco fetal ou as contra9des uterinas estejam fora dos padroes de normal idade, gerando sinais de alarme. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica
dc.title Sistema de aquisição de dados para acompanhamento de gestantes em trabalho de parto. pt_BR
dc.date.issued 2003-03-28
dc.description.abstract A system that allows the monitoring of the uterine contraction and the fetal heart beat it was projected and implemented. Important parts of this system are the sensors, which assist to the following criteria: to be not invasive and to provide comfort to the pregnant. For acquisition' of the; uterine-contraction, initially, the use of a sensor capacitive was investigated by.testing.it in the pregnant. The obtained results showed that the sensor capacitive didn't present appropriate sensibility to the pressure variation. It was invested in the search of a new one sensor that could offer a better sensibility, which happened in two stages: one relative to the project and construction of the mechanical structure and other relative one to the project and assembly of an electronic circuit. The beginning of operation of the sensor developed is to do to vary an inductance, when an uterine contraction happens. For acquisition of the fetal heart beat a sensor in the detector of heart beat, DF-4001 was used based on Doppler effect. Starting from the sign obtained in the detector was projected' and implemented an electronic circuit that it counts the beat pulses and it presents the result in a display case of 7 segments. For the storage of the acquired data.for the sensor of uterine contraction and of the fetal heart beat, it was developed a software for the microcontrolador MC6SHC11 to accomplish the measurement of the period among two pulses and later it was enlarged so that the same could measure 10 periods T, and to obtain an average of the measurements. Decisions are made in the microcontrolador regarding the cases in that the tax of fetal heart beat or the uterine contractions are out of the normality patterns, generating alarm signs.
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10321
dc.date.accessioned 2019-12-18T18:12:16Z
dc.date.available 2019-12-18
dc.date.available 2019-12-18T18:12:16Z
dc.type Dissertação pt_BR
dc.subject Sistema de Aquisição de Dados
dc.subject Aquisição de Sinais - Gestantes - Trabalho de Parto
dc.subject Sensores
dc.subject Sensor Capacitivo
dc.subject Circuito Eletrônico
dc.subject Armazenamento dos Dados
dc.subject Microcontrolador
dc.subject Data Acquisition System
dc.subject Signal Acquisition - Pregnant Women - Labor
dc.subject Sensors
dc.subject Capacitive Sensor
dc.subject Eletronic Circuit
dc.subject Data Storage
dc.subject Microcontroller
dc.rights Acesso Aberto pt_BR
dc.creator BARBOSA, Antenor Farias.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Data acquisition system for monitoring pregnant women in labor. pt_BR
dc.identifier.citation BARBOSA, Antenor Farias. Sistema de aquisição de dados para acompanhamento de gestantes em trabalho de parto. 2003. 128f. (Dissertação de Mestrado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2003. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta