DSpace/Manakin Repository

Dimensionamento de um edifício residencial de cinco pavimentos em alvenaria estrutural de acordo com a ABNT NBR 15961-1:2011 com análise do efeito arco.

Mostrar registro simples

dc.creator.ID VIEIRA, C. A. S. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/0348367035475102 pt_BR
dc.contributor.advisor1 MAIA, Cibelle Dias de Carvalho Dantas.
dc.contributor.advisor1ID MAIA, C. D. C. D. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/7557494911644798 pt_BR
dc.contributor.referee1 GUEDES, Saul Barbosa.
dc.contributor.referee2 MEDEIROS, Eduardo Morais de.
dc.contributor.referee3 MONTEIRO, Hellykan Berliet dos Santos.
dc.description.resumo O setor da construção civil está em constante desenvolvimento a fim de se obter materiais e métodos construtivos e estruturais que melhor se adaptem às necessidades de cada região e perfil de obra, primando por meios mais eficientes, econômicos e sustentáveis. A alvenaria estrutural evoluiu bastante nas últimas décadas tornando-se um dos sistemas construtivos mais sustentáveis por conta da racionalização que acarreta na redução dos resíduos gerados, constituindo-se como um dos sistemas construtivos mais usuais atualmente devido a plena capacidade de atender à demanda do setor por meios mais eficientes e ambientalmente viáveis. Desta forma, objetivou-se com o presente trabalho dimensionar um edifício residencial de cinco pavimentos em alvenaria estrutural de blocos de concreto realizado de acordo com a ABNT NBR 15961-1:2011 e analisar seu arqueamento. As lajes foram pré-dimensionadas segundo ABNT NBR 6118:2014 e o levantamento das cargas verticais conforme a ABNT NBR 6120:2019. Calculou-se o efeito arco pela equação de Riddington e Smith (1978), devido sua simplicidade e ao fato de apresentar resultados bastante próximos da realidade. Observou-se a ocorrência do efeito arco com um aumento de tensões nas paredes da edificação e os parâmetros essenciais responsáveis por tal ocorrência. Fica evidente o aumento de tensões próximo aos apoios e a necessidade de considerar a interação parede e viga no dimensionamento de edifícios de alvenaria estrutural apoiadas sobre vigas, sendo indispensável para evitar o aparecimento de patologias e para que consiga atender aos padrões de desempenho esperados. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Ciências e Tecnologia Agroalimentar - CCTA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Civil pt_BR
dc.title Dimensionamento de um edifício residencial de cinco pavimentos em alvenaria estrutural de acordo com a ABNT NBR 15961-1:2011 com análise do efeito arco. pt_BR
dc.date.issued 2019-11-28
dc.description.abstract The construction sector is constantly developing in order to obtain construction and structural materials and methods that best adapt to the needs of each region and work profile, striving for more efficient, economical and sustainable means. Structural masonry has evolved considerably in recent decades, becoming one of the most sustainable building systems due to the rationalization that leads to the reduction of waste generated, constituting one of the most common building systems currently due to the full capacity to meet the demand of the sector, by more efficient and environmentally viable means. Thus, the objective of this work was to design a five-storey residential building in structural masonry of concrete blocks made in accordance with ABNT NBR 15961-1: 2011 and analyze its arch. The slabs were pre-dimensioned according to ABNT NBR 6118: 2014 and the lifting of vertical loads according to ABNT NBR 6120: 2019. The arc effect was calculated by the Riddington and Smith (1978) equation, due to its simplicity and the fact that it presents results that are close to reality. The occurrence of the arc effect was observed with an increase of tensions in the walls of the building and the essential parameters responsible for such occurrence. It is evident the increase of stresses close to the supports and the need to consider the interaction wall and beam in the design of structural masonry buildings supported on beams, being indispensable to avoid the appearance of pathologies and to meet the expected performance standards. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10327
dc.date.accessioned 2019-12-19T09:37:23Z
dc.date.available 2019-12-19
dc.date.available 2019-12-19T09:37:23Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Alvenaria estrutural pt_BR
dc.subject Structural masonry pt_BR
dc.subject Dimensionamento pt_BR
dc.subject Sizing pt_BR
dc.subject Interação parede-viga pt_BR
dc.subject Wall beam-interaction pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator VIEIRA, Carlos Alexandre da Silva.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Design of a five-storey residential building in structural masonry according to ABNT NBR 15961-1: 2011 with arc effect analysis pt_BR
dc.identifier.citation VIEIRA. Carlos Alexandre da Silva. Dimensionamento de um edifício residencial de cinco pavimentos em alvenaria estrutural de acordo com a ABNT NBR 15961-1:2011 com análise do efeito arco. 2019. 85 f. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Civil) - Centro de Ciências e Tecnologia Agroalimentar, Universidade Federal de Campina Grande, Pombal, Paraíba, Brasil, 2019. pt_BR