dc.creator.ID |
ALMEIDA, F. P. |
pt_BR |
dc.creator.Lattes |
http://lattes.cnpq.br/9163714839391611 |
pt_BR |
dc.contributor.advisor1 |
LIMA, Vera Lúcia Antunes de. |
|
dc.contributor.advisor1 |
AZEVEDO, Carlos Alberto Vieira de. |
|
dc.contributor.advisor1ID |
LIMA, V. L. A. |
pt_BR |
dc.contributor.advisor1ID |
AZEVEDO, C. A. V. |
|
dc.contributor.advisor1Lattes |
http://lattes.cnpq.br/5379077061489077 |
pt_BR |
dc.contributor.advisor1Lattes |
http://lattes.cnpq.br/4086387731166686 |
|
dc.contributor.referee1 |
ALMEIDA, Hermes Alves de. |
|
dc.contributor.referee2 |
DANTAS NETO, José. |
|
dc.description.resumo |
Esta pesquisa teve como objetivo avaliar o desempenho hidráulico de
diferentes sistemas de drenagem subterrânea sob condições controladas de laboratório, usando-se um modelo físico horizontal de tanque de areia. Os sistemas drenantes foram compostos pelos seguintes materiais: tubo de PVC liso próprio para esgoto, com diâmetro nominal de 50,0 mm e área aberta de 23,0 cm2.m"'; tubo de PVC corrugado flexível Drenoflex. com diâmetro nominal de 65,0 mm e área aberta de 23,0 cm2.m_1; tubo Kananet de polietileno de alta densidade corrugado e flexível da Kanaflex, com diâmetro nominal
de 75,0 mm e área aberta de 110,0 cm2.m-1; e os envoltórios constituídos de manta sintética de poliéster bidim OP-20, brita zero e a manta sintética de poliuretano espuma com 5,0 mm de espessura. O arranjo estatístico utilizado foi do tipo fatorial, em que os nove
tratamentos com três repetições cada envolveram todas as combinações entre tubo drenante e envoltório. A avaliação do desempenho dos sistemas drenantes baseou-se em parâmetros típicos de avaliação propostos na literatura. Com referenda a carga hidráulica de entrada, todos os materiais drenantes foram classificados como regular. Considerando a razão entre as cargas hidráulicas de entrada e total, os resultados obtidos não foram satisfatórios. Em
relação a resistência de entrada, constatou-se que houve diferença significativa para todos os sistemas drenantes. O tubo de PVC liso apresentou maior resistência de entrada com o envoltório de espuma. Constatou-se também que entre os sistemas avaliados, os menores
valores da resistência de entrada foram obtidos com o uso do envoltório de brita zero, seguido do envoltório de espuma nos tubos convencionais. Todos os sistemas drenantes foram classificados como bons a muito bons Quanto ao fluxo, constatou-se que todos os materiais drenantes com os envoltórios de bidim e de brita zero não apresentaram diferença. Os materiais drenantes convencionais Drenoflex e Kananet não diferiram com o uso do envoltório de espuma. Para todos os sistemas drenantes, a maior e a menor descarga
foram constatadas com o uso dos envoltórios de brita zero e bidim, respectivamente. Na avaliação quanto ao fator de resistência de entrada, verificou-se que todos os sistemas drenantes apresentaram seus valores compreendidos entre os limites estabelecidos na
literatura, sendo considerados como muito bons. |
pt_BR |
dc.publisher.country |
Brasil |
pt_BR |
dc.publisher.department |
Centro de Tecnologia e Recursos Naturais - CTRN |
pt_BR |
dc.publisher.program |
PÓS-GRADUAÇÃO EM ENGENHARIA AGRÍCOLA |
pt_BR |
dc.publisher.initials |
UFCG |
pt_BR |
dc.subject.cnpq |
Engenharia Agrícola |
|
dc.title |
Avaliação de sistemas drenantes alternativos na drenagem subterrânea. |
pt_BR |
dc.date.issued |
2011-03 |
|
dc.description.abstract |
The purpose of this research was to evaluate the hydraulic performance of different subsurface drainage systems under laboratory controlled conditions, using a sand tank horizontal physical model. The drainage systems were composed by the following materials: smooth PVC pipe for sewage, with nominal diameter of 50.0 mm and opened
area of 23,0 cm2.m"'; Drenoflex corrugated flexible PVC pipe, with nominal diameter of 65,0 mm and opened area of 23,0 cm2.m"K, Kananet corrugated flexible polyethylene pipe of high density from the Kanaflex, with nominal diameter of 75,0 mm and opened area of
110,0 cm2.m_ 1; and the envelopes made of OP-20 bidim polyester synthetic blanket, zero crush, and foam polyurethane synthetic blanket, with 5,0 mm of thickness. The factorial statistical arrangement was used, where the nine treatments with three repetitions each, involved all combinations between drainage pipe and envelope. The evaluation of the drainage systems performance was based on typical parameters proposed in the literature. Respecting to inlet hydraulic head, all drainage systems were classified as regular. Considering the ratio between the inlet and total hydraulic head, the obtained results
weren't satisfactory. Regarding the entrance resistance, it was verified significant difference for all drainage systems. The smooth PVC pipe presented larger entrance resistance with the foam envelope. Also, it was verified that the smaller values for the entrance resistance were obtained with the use of zero crush envelope, followed by the
foam envelope in the conventional pipes. A l l drainage systems were classified good to very good. Regarding the outflow, it was verified that all drainage pipes with bidim and zero crush envelopes didnt presented difference. The Drenoflex and Kananet conventional drainage pipes didn't differ with the foam envelope use. For all drainage systems, the
highest and lowest discharges were fund with the use of zero crush and bidim envelopes, respectively. In the evaluation regarding the entrance resistance factor, all drainage systems presented values between the limits established in the literature, being considered
as very good. |
pt_BR |
dc.identifier.uri |
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10489 |
|
dc.date.accessioned |
2019-12-26T12:40:45Z |
|
dc.date.available |
2019-12-26 |
|
dc.date.available |
2019-12-26T12:40:45Z |
|
dc.type |
Dissertação |
pt_BR |
dc.subject |
Drenagem Subterrânea |
|
dc.subject |
Desempenho Hidráulico |
|
dc.subject |
Tanque de Areia |
|
dc.subject |
Sistemas Drenantes |
|
dc.subject |
Condutividade Hidráulica Saturada |
|
dc.subject |
Prorosidade Drenável |
|
dc.subject |
Underground Drainage |
|
dc.subject |
Hydraulic Performance |
|
dc.subject |
Sand Tank |
|
dc.subject |
Drainage Systems |
|
dc.subject |
Saturated Hydraulic Conductivity |
|
dc.subject |
Drainable Porosity |
|
dc.rights |
Acesso Aberto |
pt_BR |
dc.creator |
ALMEIDA, Florício Pinto de. |
|
dc.publisher |
Universidade Federal de Campina Grande |
pt_BR |
dc.language |
por |
pt_BR |
dc.title.alternative |
Evaluation of alternative drainage systems in underground drainage. |
pt_BR |
dc.identifier.citation |
ALMEIDA, Florício Pinto de. Avaliação de sistemas drenantes alternativos na drenagem subterrânea. 2001. 81f. (Dissertação) Mestrado em Engenharia Agrícola, Programa de Pós-Graduação em Engenharia Agrícola, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba - Campus II - Campina Grande - Paraíba - Brasil, 2001. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10489 |
pt_BR |