LOPES, W. G.; http://lattes.cnpq.br/2527331990875849; LOPES, Waneide Gomes.
Abstract:
The present work has the objective to monitor the performance of the
following desalinization reverse osmosis systems: Sitio Amorim and Sitio
Carretao, both of them located in Campina Grande city at the Paraiba state. In
order to observe the situations in terms of water quality and operation for the
systems a technical diagnostic was necessary to do.
Samples of the well water, permeate and the concentrated were collected
to be analysed the physical-chemical compounds, which were used to study de
performance of the cleaning of membranes and in the simulator design for
desalinization membrane systems.
Considering the feed water for system 1 of 3030.0 mg.L"1 of STD the
permeate production was of 0.9 m3.h"1 at 191.0 mg.L"1 of STD, while the system 2
the feed water shown 10063.3 mg.L"1 of STD its production was 0.55 m3.h"1 at
364.0 mg.L"1 of STD.