dc.description.resumo Faltas de alta impedância (FAI) são distúrbios graves e preocupantes nos sistemas de distribuição de energia elétrica. Devi do aos baixos níveis de corrente de falta, os principais dispositivos de proteção desses sistemas não são capazes de diagnosticá-las com precisão. Neste sentido, métodos de detecção e localização de FAI vêm sendo foco de interesse de muitas pesquisas. Tais métodos são, muitas vezes, validados com auxilio de simulações computacionais. Quanta mais próximo estes modelos consigam chegar das características encontradas no fenômeno real, mais confiáveis serão os algoritmos de diagnostico neles baseados. Desta forma, neste trabalho e apresentado um modelo de FAI que apresenta as principais características das correntes de falta deste distúrbio, tais como: baixos níveis de sobrecorrente, assimetria entre os semiciclos, não-linearidade, buildup, shoulder e intermitência. O modelo se baseia em oscilografias reais de FAI obtidas em ensaios de campo. As simulações foram realizadas no software ATP e o modelo foi implementado usando a linguagem MODELS. O modelo leva em consideração o tipo de superfície de contato, e contempla um número maior de características do que os modelos estudados. Com uma modelagem especifica para cada tipo de superfície, uma base de dados foi criada, na qual os arquivos finais foram convertidos para o padrão IEEE COMTRADE. Esse padrão e utilizado pela maioria dos RDP, qualímetros e reles oscilográficos do sistema elétrico, permitindo assim, que dados reais sejam inseridos a base de dados simulados sem a necessidade de nenhum tipo de conversão de formato. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica
dc.title Uma revisão de modelos clássicos de faltas de alta impedância para efeito de melhoramento. pt_BR
dc.date.issued 2011-09-09
dc.description.abstract High impedance faults (HIF) are serious and troubling disturbances in distribution systems of electric power. Due to their fault current low levels, the main power system protection devices are not able to diagnose them accurately. In this sense, HIF detection and location methods have been the focus of many researches. Such methods are often validated with the aid of computer simulations. The closer these models can reach the characteristics found in real phenomenon, the more reliable will be the diagnostic algorithms based on them. Thus, this paper presents a model of HIF which takes into account the main fault currents characteristics of the disturbance, such as: low levels of overcurrent, asymmetry between the half-cycles, nonlinearity, buildup, shoulder, and intermittence. The model is based on actual HIF oscillographic data obtained in field tests. Simulations were performed in ATP software and the model was implemented by using MODELS. At the end, it was obtained a model that takes into account the type of contact surface, and simulates a larger number of features than the evaluated models. With a specific model for each type of surface, it was created a database composed of records with IEEE COMTRADE standard. This pattern is used for most digital fault recorders (DFRs), qualimeters, and relays of the electrical system, allowing, in this way, actual data to be inserted to the simulated database without needing any kind of format conversion. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11061
dc.date.accessioned 2020-01-20T18:37:20Z
dc.date.available 2020-01-20
dc.date.available 2020-01-20T18:37:20Z
dc.type Dissertação pt_BR
dc.subject Faltas de Alta Impedância
dc.subject Banco de Dados
dc.subject Ensaios de Campo
dc.subject Modelagem de Falta
dc.subject Transitórios Eletromagnéticos
dc.subject High Impedance Fault
dc.subject Database
dc.subject Field Tests
dc.subject Fault Modeling
dc.subject Electromagnetic Transients
dc.rights Acesso Aberto pt_BR
dc.creator SANTOS, Wellinsílvio Costa dos.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative A review of classic models of high impedance faults for improvement purposes. pt_BR
dc.identifier.citation SANTOS, Wellinsílvio Costa dos. Uma revisão de modelos clássicos de faltas de alta impedância para efeito de melhoramento. 2011. 75 f. Dissertação (Mestrado em Engenharia Elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande, Paraíba, Brasil, 2011. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta