dc.description.resumo |
No sistema de lodo ativado um dos parâmetros operacionais mais importantes
e a taxa de consumo de oxigênio (TCO) que representa a velocidade de respiração
dos microrganismos presentes no sistema de tratamento. A respirometria e aplicada
a medição e interpretação da TCO em sistemas aeróbios de tratamento, sendo
usado para tanto algum tipo de respirômetro. A TCO e o parâmetro mais indicado
para avaliar a toxicidade de um afluente porque o lançamento de uma descarga
toxica resultara numa diminuição da velocidade de consumo de oxigênio pelos
microrganismos intoxicados e, portanto, da TCO. Nesta dissertação, descreve-se a experiencia obtida com um respirômetro
automatizado que foi instalado na Estação de Tratamento de Efluentes (ETE) da
CETREL no Polo Petroquímico de Camaçari na Bahia. A ETE da CETREL, trata
todos os efluentes industriais do Polo e, por esta razão, ha descargas frequentes de
materiais potencialmente tóxicos que podem abalar a estabilidade operacional do
sistema de tratamento. Portanto, na CETREL o respirômetro funcionou
principalmente como um toxímetro. O respirômetro utilizado na investigação experimental, da qual trata esta dissertação, media a TCO a partir da variação da concentração de oxigênio
dissolvido no licor misto de um sistema de lodo ativado em escala de laboratório. O
instrumento era composto de duas unidades que funcionavam independentemente,
podendo ser testados dois efluentes simultaneamente. Tal configuração foi
escolhida para aumentar a flexibilidade operacional e aumentar a confiabilidade nas
informações obtidas. No caso da investigação experimental, optou-se por
determinar a TCO, usando-se a vazão dos efluentes industriais brutos e
equalizados que chegam na ETE da CETREL. Alem da variação da concentração
de OD e o calculo subsequente da TCO, o respirômetro também registrava o valor
da temperatura em função do tempo. O "software" Toxim-D, desenvolvido para o
respirômetro permitiu o controle da aeração e a determinação direta das três
variáveis, que podiam ser armazenadas na memoria do computador para análise
posterior.O uso do respirômetro na CETREL mostrou os seguintes pontos importantes: (1) em condições normais o efluente bruto tem uma TCO que varia de
maneira acentuada e imprevisível com o tempo, indicando que há introdução
frequente (algumas vezes por dia) de sobre cargas orgânicas e material toxico no
sistema de tratamento; (2) a TCO do efluente equalizado tem uma variação muito gradual e previsível. Sob condições operacionais normais, as oscilações da TCO podem ser
atribuídas, principalmente, as variações da temperatura e da concentração de
material orgânico; (3) em algumas ocasiões, os reatores com efluente equalizado e efluente industrial indicaram a presença de material toxico no momento que coincidiu com
um período de problemas operacionais na estação, onde se detectou uma alta
concentração de compostos considerados poluentes prioritários, letal para as
bactérias. |
pt_BR |
dc.publisher.country |
Brasil |
pt_BR |
dc.publisher.department |
Centro de Tecnologia e Recursos Naturais - CTRN |
pt_BR |
dc.publisher.program |
PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTAL |
pt_BR |
dc.publisher.initials |
UFCG |
pt_BR |
dc.title |
Utilização da respirometria no controle operacional de sistemas aeróbios de tratamento de águas residuárias. |
pt_BR |
dc.date.issued |
1999-03 |
|
dc.description.abstract |
In the activated sludge system one of the most important operational
parameters is the oxygen uptake rate (OUR) . which represents the respiration rate
speed of micro organisms present in the treatment system. Respirometry is used for
measurement and interpretation of OUR in treatment aerobic systems, with the aid of
some type of respirometer. OUR is the most indicated parameter to evaluate the
toxicity of a influent, because the release of a toxic discharge will result in a
decrease of the oxygen consumption rate by the intoxicated micro organisms and
therefore, of OUR.
In this dissertation, the experience obtained with an automated respirometer
installed in the Effluent Treatment Plant (ETE) of CETREL at the Petrochemical
Complex of Camacari in Bahia is described. The ETE of CETREL treats all the
industrial effluents of the Complex and, for this reason, there are frequent
discharges of material that potentially are toxic and these can affect the operational
stability of the treatment system. Therefore, at CETREL the respirometer operated
mainly as a toxicity meter.
The toxicity meter used during the experimental investigation, of this
dissertation, measured OUR from the variation of the Dissolved Oxygen (DO)
concentration in the mixed liquor of an activated sludge systems at laboratory scale.
The instrument was composed of two units that worked independently, so that two
wastewaters could be tested simultaneously. Such configuration was chosen to
increase operational flexibility and augment the reliability of the obtained
information. In the case of the experimental investigation, the raw and equalised
industrial effluent arriving ate the ETE of CETREL were chosen to determine OUR,
Along with the variation of the DO concentration and the subsequent calculation of
OUR, the toxicity meter also acquired the value of the temperature as a function of
time. The software Toxim-D, developed for the toxicity meter allowed the control of
aeration and the on-line determination of the three variables, that were stored in the
memory of the computer for posterior analysis.
The use of the toxicity meter at CETREL showed the following important
points: (1) under normal conditions the raw industrial effluent has a OUR that varies
significantly and in a unpredictable way with the time, indicating that there is
frequent introduction (a few times a day) of organic over loads and toxic material in
the treatment system;
(2) OUR of the equalised effluent exhibit very gradual and predicabie
variations. Under normal operational conditions, the oscillations of OUR can be
attributed, mainly, to variations of the temperature and of the concentration of
organic material;
(3) at some occasions, the reactors with raw and with equalised effluents
indicated the presence of toxic material on moments that coincided with periods of
operational problems in the station, where a high concentration of priority pollutants
was detected, lethal for the bacteria. |
pt_BR |
dc.identifier.uri |
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11200 |
|
dc.date.accessioned |
2020-01-24T14:22:50Z |
|
dc.date.available |
2020-01-24 |
|
dc.date.available |
2020-01-24T14:22:50Z |
|
dc.type |
Dissertação |
pt_BR |
dc.subject |
Águas Residuárias - Tratamento |
|
dc.subject |
Lodo Ativado |
|
dc.subject |
Respirometria |
|
dc.subject |
Controle Operacional |
|
dc.subject |
Efluentes Líquidos |
|
dc.subject |
Resíduos Sólidos Perigosos |
|
dc.subject |
Wastewater - Treatment |
|
dc.subject |
Activated Sludge |
|
dc.subject |
Respirometry |
|
dc.subject |
Operational Control |
|
dc.subject |
Liquid Effluents |
|
dc.subject |
Hazardous Solid Waste |
|
dc.rights |
Acesso Aberto |
pt_BR |
dc.creator |
FERNANDES, José Gilson Santos. |
|
dc.publisher |
Universidade Federal de Campina Grande |
pt_BR |
dc.language |
por |
pt_BR |
dc.title.alternative |
Use of respirometry in the operational control of aerobic wastewater treatment systems. |
pt_BR |
dc.identifier.citation |
FERNANDES, José Gilson Santos. Utilização da respirometria no controle operacional de sistemas aeróbios de tratamento de águas residuárias. 1999. 127f. (Dissertação de Mestrado em Engenharia Civil e Ambiental), Curso de Pós-Graduação em Engenharia Civil, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba – Campus II - Campina Grande - PB - Brasil, 1999. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11200 |
pt_BR |