dc.description.resumo |
Fósforo e um dos principais nutrientes responsáveis pela eutrofização de corpos d'água
receptores. Concentrações superiores a 0,03 mg/L caracterizam um lago como eutrófico.
Para evitar problemas com eutrofização o fosforo tem que ser removido de efluentes de
estacoes de tratamento de esgoto antes da descarga destes em corpos d'água receptores. Na
pratica, fosforo pode ser removido biologicamente em reatores aeróbios desde que a relação P/DQO seja suficientemente alta ou através de tratamento físico-químico, sabendo-se que alguns fosfatos formam precipitados. Em sistemas de tratamento anaeróbio-aeróbio a unica
alternativa de se produzir um efluente com baixa concentração de fosforo e através do
tratamento físico-químico. Neste contexto, foi realizada uma investigação experimental em escala piloto com o objetivo de se estabelecer a viabilidade da remoção físico-química de
fosforo em um sistema de tratamento anaeróbio-aeróbio usando cloreto férrico (FeCb) e
sulfato de alumínio (A1(SO4)3). Os resultados indicaram que a remoção parcial de fósforo e
factível, mas que para se obter um efluente com baixa concentração de fosforo e requerida uma alta dosagem de ambos os coagulantes. Os resultados mostraram que o cloreto férrico é mais recomendável por causa do seu baixo preço e porque traz menos problemas para disposição final com o lodo produzido. |
pt_BR |
dc.publisher.country |
Brasil |
pt_BR |
dc.publisher.department |
Centro de Tecnologia e Recursos Naturais - CTRN |
pt_BR |
dc.publisher.program |
PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTAL |
pt_BR |
dc.publisher.initials |
UFCG |
pt_BR |
dc.title |
Remoção físico-química de fósforo de efluentes de sistemas anaeróbios-aeróbios de tratamento de esgoto doméstico. |
pt_BR |
dc.date.issued |
2005-08 |
|
dc.description.abstract |
Phosphorus is one of the most important macro nutrients responsible for eutrophication of
surface waters. A concentration of 0,03 mg/L indicates an eutrophic condition in a lake. To
avoid problems with eutrophication, there is a need to remove phosphorus from effluents
produced in sewage treatment plants that are to be discharged into surface waters. In
practice, phosphorus can be removed by biological means in aerobic treatment plants if the
P/COD ratio is high enough, or by physical chemical treatment, using the fact that several
phosphates are poorly soluble. In anaerobic- aerobic plants, the only alternative to produce
an effluent with a low P concentration is the application of physical chemical treatment. A
bench scale experimental investigation was carried on with the objective to establish the
feasibility of physical chemical phosphorus removal in anaerobic-aerobic sewage treatment
plants, using both ferric chloride (FeCh) and aluminium sulfate (A^CSO^). The results
indicated that the partial removal is feasible, but for a low effluent P concentration a high
dosage of either coagulant is required. The results also indicated that ferric chloride is more
recommendable because of its low price per mass unit and a less problematic final disposal
of the produced sludge. |
pt_BR |
dc.identifier.uri |
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11289 |
|
dc.date.accessioned |
2020-01-28T12:44:43Z |
|
dc.date.available |
2020-01-28 |
|
dc.date.available |
2020-01-28T12:44:43Z |
|
dc.type |
Dissertação |
pt_BR |
dc.subject |
Águas Residuárias - Tratamento Biológico |
|
dc.subject |
Águas Residuárias - Tratamento Físio-químico |
|
dc.subject |
Reator UASB |
|
dc.subject |
Sistema de Lodo Ativado |
|
dc.subject |
Remoção de Fásforo |
|
dc.subject |
Esgoto Doméstico |
|
dc.subject |
Wastewater - Biological Treatment |
|
dc.subject |
Wastewater - Physicochemical Treatment |
|
dc.subject |
UASB Reactor |
|
dc.subject |
Activated Sludge System |
|
dc.subject |
Phosphorus removal |
|
dc.subject |
Domestic Sewer |
|
dc.rights |
Acesso Aberto |
pt_BR |
dc.creator |
SANTOS, José Claúdio Silveira dos. |
|
dc.publisher |
Universidade Federal de Campina Grande |
pt_BR |
dc.language |
por |
pt_BR |
dc.title.alternative |
Physical-chemical removal of phosphorus from effluents from anaerobic-aerobic systems for domestic sewage treatment. |
pt_BR |
dc.identifier.citation |
SANTOS, José Claúdio Silveira dos. Remoção físico-química de fósforo de efluentes de sistemas anaeróbios-aeróbios de tratamento de esgoto doméstico. 2005. 111f. (Dissertação de Mestrado em Engenharia Civil e Ambiental), Programa de Pós-Graduação em Engenharia Civil e Ambiental, Universidade Federal de Campina Grande - Paraíba - Brasil, 2011. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11289 |
pt_BR |