DSpace/Manakin Repository

Desempenho de um sistema wetland no tratamento de um córrego afluente ao açude de Bodocongó: segundo ano de funcionamento.

Mostrar registro simples

dc.creator.ID RAIMUNDO SOBRINHO, J. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/7384474220529593 pt_BR
dc.contributor.advisor1 CEBALLOS, Beatriz Susana Ovruski de.
dc.contributor.advisor1ID CEBALLOS, B. S. O. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/9321950498637802 pt_BR
dc.contributor.advisor2 SOUSA, José Tavares de.
dc.contributor.advisor2ID http://lattes.cnpq.br/9348418607084437
dc.contributor.referee1 SILVA, Flávio Luiz Honorato da.
dc.contributor.referee2 KONIG, Annemarie.
dc.description.resumo O tratamento por métodos simples e de baixo custo de águas superficiais poluídas, tem se tornado cada vez mais necessário para a sobrevivência de rios e açudes bem como para propiciar o reuso dessas águas na irrigação. Com estas finalidades foi realizada no Campus II da Universidade Federal da Paraíba (Campina Grande, Paraíba, Brasil) a presente pesquisa para se avaliar um sistema de wetland artificial (ou construído) usando Typha spp. O sistema foi montado em 10 tanques brasilit de 250L, enchidos com brita (19mm) e alimentados em bateladas com água do córrego que atravessa o Campus II dessa Universidade, com vazões calculadas para tempo de detenção hidráulica de 5 e 10 dias, através de fluxo subsuperficial. Em 8 desses tanques se plantaram 8 própágulos de Typha spp (densidade de 20 propagulos/m2) enquanto os outros 2 tanques sem macrófitas foram usados como controle. A eficiência do sistema foi avaliada com base nos parâmetros físicos, químicos e microbiológicos de qualidade da água, medidos no afluente e nos efluentes dos tanques. A analise estatística dos resultados foi feita sobre dois conjuntos de dados: os obtidos ao longo dos seis meses da presente pesquisa (Janeiro a junho de 2001) e os referentes ao 1° ano de funcionamento (Janeiro a dezembro de 2000), perfazendo um total de dezoito meses. Os resultados mostraram que o sistema apresentou eficiência significativa na purificação da água. Para os dois tempos de detenção hidráulica, as remoções verificadas nos últimos seis meses foram, em media: 82 e 89% da turbidez; 83 e 88% da DB05; 100% do nitrogênio amoniacal; 84 e 86% do fosforo total; 96% do ortofosfato solúvel e 99,9% de coliformes e estreptococos fecais. A temperatura e o pH permaneceram praticamente constantes, enquanto outros parâmetros apresentaram grandes acréscimos como: condutividade elétrica (83 e 106%), bicarbonatos (64 e 90%), cloretos (194 e 220%), sódio (165 e 228%), cálcio (96 e 114%), magnésio (103 e 141%), alealinidade total (67 e 92%) e dureza total (92 e 111%). Comparando os resultados deste período com os dados dos 12 meses anteriores, especialmente os correspondentes ao período de mesma climatologia (semestres I), constata-se que o desempenho do sistema aumentou ao longo do tempo, com o crescimento das plantas e do seu sistema radicular. A analise de variância ao nível de 5% de significância, mostrou diferenças dentro dos tratamentos para os parâmetros: sólidos totais, nitrogênio amoniacal, nitrato, fosforo, coliformes fecais e estreptococos fecais. O teste de Tukey, aplicado também aos dados desses dois períodos, não identificou diferenças significativas nos efluentes dos tanques vegetados com tempo de detenção hidráulica de 5 e 10 dias para as variáveis: condutividade elétrica, turbidez, pH, alealinidade, dureza, DBOs, nitrogênio amoniacal, fosforo total, coliformes fecais e estreptococos fecais. Estes efluentes, comparados aos dos tanques controles, apresentaram diferenças significativas para: condutividade elétrica, bicarbonato, sódio, cálcio, magnésio, dureza, coliformes e estreptococos fecais. Conclui-se que águas superficiais contaminadas por esgotos domésticos, podem ser tratadas em wetlands construídos com 5 dias de detenção hidráulica. Estes sistemas se caracterizam pela simplicidade de construção e manutenção e podem ser apresentados como uma alternativa para 0 melhor aproveitamento dos escassos recursos hídricos no semi-árido do nordeste brasileiro. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTAL pt_BR
dc.publisher.initials UFCG pt_BR
dc.title Desempenho de um sistema wetland no tratamento de um córrego afluente ao açude de Bodocongó: segundo ano de funcionamento. pt_BR
dc.date.issued 2002-03
dc.description.abstract The treatment of polluted surface water by simple and economic methods is becoming more and more necessary for the survival of rivers and lakes as well as it presents an opportunity of reusing these waters for irrigation. With this purpose the present research was carried out at Campus II of the Federal Paraiba University (Campina Grande, Paraiba, Brazil), to evaluate an artificial wetland system using Typha spp. The system consisted of 10 Brasilit tanks of 250 L, filled with small stone pieces ( 19 mm) and was fed in batch with stream water, that passes through Campus II of this University, with calculated discharge for a hydraulic detention of 5 and 10 days and having a subsurface flow. In 8 of these tanks 8 propagulos of Typha spp were planted while the other two tanks having no macrofitas were used as controls. The efficiency of the system was evaluated in terms of physical, chemical and biological water quality parameters measured for affluent and effluent water of the tanks. The statistical analysis of the results was made on two data groups: one that obtained along with six months of the preset research work ( January to June 2001) and the other obtained during first year of the work ( January to December 2000 ), making a total of eighteen months. The results showed that the system presented significant efficiency for the water purification. For the two periods of the water hydraulic detention the verified mean removals in the last six months were: 82 and 89% turbidity; 83 to 88% biochemical demand of oxygen BOD5; 100% ammoniacal nitrogen; 84 to 86% total phosphrorus; 96% of the soluble ortophosphate and 99% of feacal coliforms. The temperature and the pH stayed practically constant, while other parameters suffered higher increments as: electric conductivity (83 to 106%), bicarbonates (64 to 90%), chlorates (134 to 220%), sodium (165 to 228%), calcium (96 to 114%), magnesium (103 to 141%), total alkalinity (67 to 92%) and total hardness (92 to 111%). A comparison of these results with those of previous 12 months, especially corresponding to similar climatic period (first semester) it can be said that the performance of the system improved along with time with the growth of the plants and their radicule system. The variance analysis at 5% level of significance showed differences for the following parameters: total solids, ammoniacal nitrogen, nitrates, phosphorous, feacal coliforms and estreptococos coliforms. The Tukey test also applied to these two periods did not indicate any significant difference for the effluents of the vegetated tanks for the hydraulic detention time of 5 and 10 days on the variables as: electrical conductivity, turbidity, pH, alkalinity, hardness, BOD5, ammoniacal nitrogen, total phosphorous; feacal coliforms and estreptococos eoliforms. These effluents when compared with those of controle tanks, showed significant differences for: electrical conductivity, bicarbonate, sodium, calcium, magnesium, hardness, coliforms and estreptococos feacal. It is concluded that the surface waters contaminated with domestic drain can be treated through the constructed wetlands use with 5 days hydraulic detention time. These systems are characterized by their construction simplicity and maintenance and presents an alternative for the better utilization of the scarce hydraulic resources of semi-arid region of Northeast of Brazil. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11300
dc.date.accessioned 2020-01-29T09:34:52Z
dc.date.available 2020-01-28
dc.date.available 2020-01-29T09:34:52Z
dc.type Dissertação pt_BR
dc.subject Wetland Construído
dc.subject Macrófitas
dc.subject Plantas Áquáticas
dc.subject Remoção de Matéria Orgânica
dc.subject Nutrientes
dc.subject Bactérias de Águas Poluídas
dc.subject Typha spp
dc.subject Built Wetland
dc.subject Macrophytes
dc.subject Aquatic Plants
dc.subject Organic Matter Removal
dc.subject Nutrients
dc.subject Polluted Water Bacteria
dc.rights Acesso Aberto pt_BR
dc.creator RAIMUNDO SOBRINHO, José.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Performance of a wetland system in the treatment of a tributary stream to the Bodocongó reservoir: second year of operation. pt_BR
dc.identifier.citation RAIMUNDO SOBRINHO, José. Desempenho de um sistema wetland no tratamento de um córrego afluente ao açude de Bodocongó: segundo ano de funcionamento. 2002. 148f. (Dissertação de Mestrado em Engenharia Civil e Ambiental), Curso de Pós-Graduação em Engenharia Civil, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba – Campus II - Campina Grande - PB - Brasil, 2002. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11300 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta