Avaliação da susceptibilidade a trincas a frio induzidas por hidrogênio em juntas soldadas dos aços API 5L X-80 por meio do teste de implante.

Afficher la notice abrégée

dc.creator.ID MARQUES, L. N. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/3754473953019217 pt_BR
dc.contributor.advisor1 MACIEL, Theophilo Moura.
dc.contributor.advisor1ID MACIEL, T. M. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/9476858938351846 pt_BR
dc.contributor.referee1 SANTOS, Marco Antonio dos.
dc.contributor.referee2 ALMEIDA, Daisy Martins de.
dc.contributor.referee3 CASTRO, Walman Benicio de.
dc.description.resumo Neste trabalho foi avaliada a influencia dos parâmetros, processos e procedimentos de soldagem sobre a susceptibilidade a trincas a frio induzidas pelo hidrogênio (TIH) em juntas soldadas do ago API 5L X80. Para isto foram realizados ensaios de implante em soldagens executadas pelos processos SMAW e FCAW com diferentes parâmetros e procedimentos de soldagem. Os consumíveis utilizados foram o arame autoprotegido AWS E 91T8-K8 com 1,60 mm de diâmetro e com proteção gasosa (75% Ar -25%CO-,) AWS E 91T1-G com diâmetro de 1,20 mm. E os eletrodos AWS E 8010 e AWS E 8018-G, com diâmetro de 4,00 mm. Apos as soldagens os corpos de prova foram cortados transversalmente e as trincas e microtrincas, quando existentes, foram identificadas, para cada condição de soldagem sendo os resultados associados a microestrutura e ao valor de microdureza na região onde ocorreu trincamento. A microestrutura predominante foi composta por Bainita e Ferrita Primaria e todas as trincas encontradas foram de característica intergranular, entretanto não representaram um numero significativo, os como os valores de microdureza, foram todos abaixo de 238,1 HV, tanto no metal de solda como na ZTA e possível dizer que o ago estudado apresenta boa soldabilidade e não e susceptível ao TIH para as condições analisadas. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Ciências e Tecnologia - CCT pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM CIÊNCIA E ENGENHARIA DE MATERIAIS pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Ciência e Engenharia de Materiais.
dc.title Avaliação da susceptibilidade a trincas a frio induzidas por hidrogênio em juntas soldadas dos aços API 5L X-80 por meio do teste de implante. pt_BR
dc.date.issued 2013-02-27
dc.description.abstract In this study, the influence of the parameters, process and welding procedures on susceptibility to hydrogen induced cold cracking in API 5L X80 steel welded joints . Were evaluated for this Implant Test using SMAW and FCAW process with different parameters and welding procedures. Were used AWS E 91T8-K8 with 1,60 mm diameter self protected and AWS E 91T1-G with 1,20 mm diameter gas protected . And AWS E 8010 e AWS E 8018-G, with diameter 4,00 mm. After welding the specimens were cut and cracks and microcracks were identified for each welding condition and the results associated with the microstructure and microhardness value in the region where cracking occurred. It was verified that all cracks occurred were predominantly composed of Bainite and Primary Ferrite All cracks were intergranular but do not represented a significant size, as all the microhardness values were less than 238,1 HV it is possible to say that the steel studied has a good weldability and it is not likely to be susceptible to hydrogen induced cold cracking for the analyzed conditions pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11430
dc.date.accessioned 2020-02-03T11:50:33Z
dc.date.available 2020-02-03
dc.date.available 2020-02-03T11:50:33Z
dc.type Dissertação pt_BR
dc.subject Soldagem
dc.subject Aço API 5L X80
dc.subject Trincamento Induzido por Hidrogênio
dc.subject Teste de Implante
dc.subject Processos SMAW e FCAW
dc.subject Trincas
dc.subject Welding
dc.subject API 5L X80 Steel
dc.subject Hydrogen-Induced Cracking
dc.subject Implant Test
dc.subject SMAW and FCAW Processes
dc.subject Cracks
dc.rights Acesso Aberto pt_BR
dc.creator MARQUES, Lívia Neves.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Evaluation of susceptibility to cold cracks induced by hydrogen in welded joints of API 5L X-80 steels using the implant test. pt_BR
dc.identifier.citation MARQUES, Lívia Neves. Avaliação da susceptibilidade a trincas a frio induzidas por hidrogênio em juntas soldadas dos aços API 5L X-80 por meio do teste de implante. 2013. 97 f. (Dissertação de Mestrado em Ciência e Engenharia de Materiais), Programa de Pós-graduação em Ciência e Engenharia de Materiais, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande - Paraíba - Brasil, 2013. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11430 pt_BR