dc.description.resumo |
Neste trabalho foi avaliada a influencia dos parâmetros, processos e
procedimentos de soldagem sobre a susceptibilidade a trincas a frio induzidas
pelo hidrogênio (TIH) em juntas soldadas do ago API 5L X80. Para isto foram
realizados ensaios de implante em soldagens executadas pelos processos
SMAW e FCAW com diferentes parâmetros e procedimentos de soldagem. Os
consumíveis utilizados foram o arame autoprotegido AWS E 91T8-K8 com 1,60
mm de diâmetro e com proteção gasosa (75% Ar -25%CO-,) AWS E 91T1-G com
diâmetro de 1,20 mm. E os eletrodos AWS E 8010 e AWS E 8018-G, com
diâmetro de 4,00 mm. Apos as soldagens os corpos de prova foram cortados
transversalmente e as trincas e microtrincas, quando existentes, foram
identificadas, para cada condição de soldagem sendo os resultados associados
a microestrutura e ao valor de microdureza na região onde ocorreu
trincamento. A microestrutura predominante foi composta por Bainita e Ferrita
Primaria e todas as trincas encontradas foram de característica intergranular,
entretanto não representaram um numero significativo, os como os valores de
microdureza, foram todos abaixo de 238,1 HV, tanto no metal de solda como
na ZTA e possível dizer que o ago estudado apresenta boa soldabilidade e não
e susceptível ao TIH para as condições analisadas. |
pt_BR |
dc.publisher.country |
Brasil |
pt_BR |
dc.publisher.department |
Centro de Ciências e Tecnologia - CCT |
pt_BR |
dc.publisher.program |
PÓS-GRADUAÇÃO EM CIÊNCIA E ENGENHARIA DE MATERIAIS |
pt_BR |
dc.publisher.initials |
UFCG |
pt_BR |
dc.subject.cnpq |
Ciência e Engenharia de Materiais. |
|
dc.title |
Avaliação da susceptibilidade a trincas a frio induzidas por hidrogênio em juntas soldadas dos aços API 5L X-80 por meio do teste de implante. |
pt_BR |
dc.date.issued |
2013-02-27 |
|
dc.description.abstract |
In this study, the influence of the parameters, process and welding procedures
on susceptibility to hydrogen induced cold cracking in API 5L X80 steel welded
joints . Were evaluated for this Implant Test using SMAW and FCAW process
with different parameters and welding procedures. Were used AWS E 91T8-K8
with 1,60 mm diameter self protected and AWS E 91T1-G with 1,20 mm
diameter gas protected . And AWS E 8010 e AWS E 8018-G, with diameter
4,00 mm. After welding the specimens were cut and cracks and microcracks
were identified for each welding condition and the results associated with the
microstructure and microhardness value in the region where cracking occurred.
It was verified that all cracks occurred were predominantly composed of Bainite
and Primary Ferrite All cracks were intergranular but do not represented a
significant size, as all the microhardness values were less than 238,1 HV it is
possible to say that the steel studied has a good weldability and it is not likely to
be susceptible to hydrogen induced cold cracking for the analyzed conditions |
pt_BR |
dc.identifier.uri |
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11430 |
|
dc.date.accessioned |
2020-02-03T11:50:33Z |
|
dc.date.available |
2020-02-03 |
|
dc.date.available |
2020-02-03T11:50:33Z |
|
dc.type |
Dissertação |
pt_BR |
dc.subject |
Soldagem |
|
dc.subject |
Aço API 5L X80 |
|
dc.subject |
Trincamento Induzido por Hidrogênio |
|
dc.subject |
Teste de Implante |
|
dc.subject |
Processos SMAW e FCAW |
|
dc.subject |
Trincas |
|
dc.subject |
Welding |
|
dc.subject |
API 5L X80 Steel |
|
dc.subject |
Hydrogen-Induced Cracking |
|
dc.subject |
Implant Test |
|
dc.subject |
SMAW and FCAW Processes |
|
dc.subject |
Cracks |
|
dc.rights |
Acesso Aberto |
pt_BR |
dc.creator |
MARQUES, Lívia Neves. |
|
dc.publisher |
Universidade Federal de Campina Grande |
pt_BR |
dc.language |
por |
pt_BR |
dc.title.alternative |
Evaluation of susceptibility to cold cracks induced by hydrogen in welded joints of API 5L X-80 steels using the implant test. |
pt_BR |
dc.identifier.citation |
MARQUES, Lívia Neves. Avaliação da susceptibilidade a trincas a frio induzidas por hidrogênio em juntas soldadas dos aços API 5L X-80 por meio do teste de implante. 2013. 97 f. (Dissertação de Mestrado em Ciência e Engenharia de Materiais), Programa de Pós-graduação em Ciência e Engenharia de Materiais, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande - Paraíba - Brasil, 2013. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11430 |
pt_BR |