DSpace/Manakin Repository

Avaliação do desempenho da estação de tratamento de esgotos da zona leste Teresina (PI) e seu impacto no rio Poty.

Mostrar registro simples

dc.creator.ID ROCHA, M. E. S. pt_BR
dc.contributor.advisor1 KONIG, Annemarie.
dc.contributor.advisor1ID KONIG, A. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/1484397481626689 pt_BR
dc.contributor.advisor2 CEBALLOS, Beatriz Susana Ovruski de.
dc.contributor.advisor2ID CEBALLOS, B. S. O.
dc.contributor.advisor2Lattes http://lattes.cnpq.br/9321950498637802
dc.contributor.referee1 OLIVEIRA, Rui de.
dc.contributor.referee2 MOTA, Francisco Suetônio Bastos.
dc.description.resumo Este trabalho apresenta a avaliação do desempenho de um sistema de tratamento de esgotos por lagoas de estabilização da ETE Leste Teresina - (PI) e o impacto do lançamento do efluente final na qualidade das aguas do corpo receptor, o rio Poty. O sistema e constituído de tratamento preliminar (gradeamento e desarenação) e cinco lagoas de estabilização. O projeto considera a primeira lagoa da serie como sendo facultativa aerada e as demais de maturação (1, 2, 3 e 4). Uma serie de lagoas e composta pela facultativa aerada seguida pelas maturação 1 e 3 e a outra, pela facultativa aerada seguida de maturação 2 e 4. O sistema esta localizado na cidade de Teresina (5°05'13"S; 42°48'41"0; 73m acima do nível do mar), capital do estado do Piaui, Nordeste do Brasil. O período de estudo foi de marco de 1999 a novembro de 2001 e os parâmetros analisados foram temperatura, pH, DB05 , DQO, sólidos totais (ST), suas frações fixas (STF), voláteis (STV) e coliformes fecais (CF). As amostras foram coletadas as 8 horas da manha no esgoto bruto (EB), efluente final (EF), rio a montante (RM) e a jusante (RJ), ambos a 100m do ponto de descarga do efluente final. Os valores médios da DB05 do EB e EF, foram de 355 e 77mg02/l; no RM encontraram-se entre 5 e 10mgO2/l e o lançamento do EF, contribuiu para um aumento discreto em RJ, entre 6 e 16mg02/l. No periodo, as eficiências medias de remoção da matéria orgânica expressas como DB05 e DQO foram de 80% (351-77mg02/l) e 72% (525-145mg02/l) respectivamente, indicando o bom funcionamento do sistema. Os valores de sólidos totais e suas frações foram muito variados, não se verificando remoções expressivas. No esgoto bruto, os valores de CF foram típicos para águas residuárias domesticas (5,3xl07NMP/ 100ml), sendo removidos pelo sistema de tratamento em 99,9% (5,3x107- 4,4x104NMP/ 100ml), percentual considerado adequado para sistemas com esta configuração. No corpo receptor, os valores médios de coliformes fecais variaram de 9,3xl02 a 9,2xl03NMP/100ml a montante e 2,0xl03 a 4,4xl04NMP/100ml a jusante. Através da analise de variância ANOVA (fator único) seguida do método GT-2 foi possível concluir que o lançamento do efluente da ETE Leste, não causou impactos na qualidade das águas do rio Poty. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTAL pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Civil e Ambiental
dc.title Avaliação do desempenho da estação de tratamento de esgotos da zona leste Teresina (PI) e seu impacto no rio Poty. pt_BR
dc.date.issued 2002-04-26
dc.description.abstract This work presents the evaluation of a sewage treatment system by stabilization ponds named ETE Leste (Teresina City - Piaui State) and the final effluent impact on the receiving body (Poty River) water quality. The sewage treatment plant comprises preliminary treatment (screening and degriting) followed by five ponds of stabilization. The project considered the fist pond as aerated facultative followed by two series in parallel of maturation ponds named 1, 2, 3 and 4: one serie with maturation 1 and 3 and the other with maturation 2 and 4. The system is located in the sity of Teresina (5°5'13"S; 42°48'41"W; 73m above the sea level), capital of Piaui State, Northeast of Brazil. The study was carried out from March 1999 to November of 2001. The sampling point were raw sewage (RS), final effluent (FE) and river up and downstream (RUp and RD) both at 100m from final effluent discharge. Samples were analyzed for temperature, pH, BOD5 , COD, Total Solids (TS) with fixed (TFS) and volatile (TVS) fractions and fecal coliforms (FC). Mean values of BOD5 in the RS and FE were of 351 and 77mg02/l, between 5- 1 Omg02/1 in river upstream with river downstream showing a discrete BOD increase after receiving final effluent discharge (6 to 16mg02/L). During the experimental period organic matter (as BOD and COD) removal efficiencies (as BOD and COD) were 80% (351-77 mg02 /l) and 72% (525-145mg02/l) respectively, showing good performance of pond system. Total solids and fractions varied considerably and no expressive removals were found. Raw sewage FC values were typical for those found in domestic wastewater (5.3xl07MPN/ml) with pond system removing up to 99,9% (5.3xl07- 4.4xl04MPN/100ml), considered appropriate for systems with this configuration. In the receiving water body FC mean values varied between 9.2x102 to 9.3xl03MPN/100ml for upstream samples and between 2.0x103 to 4.4x104MPN/ 100ml to downstream samples. Although the data haven't demonstrated a river impact caused by the final effluent discharge, the analysis of variance (ANOVA-one way) followed by the GT-2 graphic method demonstrated that those alterations were not significant. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11708
dc.date.accessioned 2020-02-10T14:12:35Z
dc.date.available 2020-02-10
dc.date.available 2020-02-10T14:12:35Z
dc.type Dissertação pt_BR
dc.subject Lagoas de Estabilização
dc.subject Tratamento de Esgotos
dc.subject Recursos Hídricos
dc.subject Águas Residuárias
dc.subject Lagoas Anaeróbias
dc.subject Lagoas Facultativas
dc.subject Lagoas de Maturação
dc.subject Stabilization Ponds
dc.subject Sewage Treatment
dc.subject Water resources
dc.subject Residual Waters
dc.subject Anaerobic Lagoons
dc.subject Optional Ponds
dc.subject Maturation Ponds
dc.rights Acesso Aberto pt_BR
dc.creator ROCHA, Maria Elgenir Silva da.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Performance evaluation of the sewage treatment plant in the eastern Teresina (PI) and its impact on the Poty River. pt_BR
dc.identifier.citation ROCHA, Maria Elgenir Silva da. Avaliação do desempenho da estação de tratamento de esgotos da zona leste Teresina (PI) e seu impacto no rio Poty. 2002. 108f. (Dissertação) Mestrado em Engenharia Civil e Ambiental, Curso de Pós-Graduação em Engenharia Civil, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba – Campus II - Campina Grande - Paraíba - Brasil, 2002. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11708 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta