DSpace/Manakin Repository

Considerações de projeto para anemômetros a fio quente baseado em estruturas realimentadas.

Mostrar registro simples

dc.creator.ID DINIZ, R. C. S. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/7915381755425396 pt_BR
dc.contributor.advisor1 FREIRE, Raimundo Carlos Silvério.
dc.contributor.advisor1 MELO, Hiran de.
dc.contributor.advisor1ID FREIRE, R. C. S. pt_BR
dc.contributor.advisor1ID MELO, H.
dc.contributor.advisor1ID MELO, H.
dc.contributor.advisor1ID MELO, H.
dc.contributor.advisor1Lattes http://lattes.cnpq.br/4016576596215504 pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/2127559774805521
dc.contributor.advisor1Lattes http://lattes.cnpq.br/2127559774805521
dc.contributor.advisor1Lattes http://lattes.cnpq.br/2127559774805521
dc.contributor.referee1 FERREIRA, Rômulo Pires Coelho.
dc.contributor.referee2 SILVA, Antonio Almeida da.
dc.contributor.referee3 CATUNDA, Sebastian Yuri Cavalcanti.
dc.description.resumo Os anemômetros baseados no principio de medição da velocidade do fluido a partir da transferência de calor, que usam sensores termo-resistivos aquecidos eletricamente, são chamados de "Anemômetros a Fio Quente". Eles podem ser classificados como instrumento elétrico de medição, pois o tipo de sensor utilizado modifica um parâmetro elétrico, grandeza que o instrumento ira processar, em função da grandeza que se deseja medir. No sentido de determinar a velocidade do fluido a partir de um parâmetro elétrico, utiliza-se o principio da equivalência elétrica nas arquiteturas de medição, dentre as estruturas existentes, investigou-se a estrutura a temperatura do sensor constante, conhecida pela sigla "CTA", do inglês "Constant Temperature Anemometer". Neste trabalho apresentam-se considerações de projeto para implementação de CTA com realimentação PWM, além de procedimentos para caracterização de sensores, circuitos para compensação de temperatura do fluido e um sistema de aquisição de dados. Baseado nas considerações de projeto apresentadas neste trabalho, implementou-se um CTA com excitação PWM que mede a velocidade do ar. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica
dc.title Considerações de projeto para anemômetros a fio quente baseado em estruturas realimentadas. pt_BR
dc.date.issued 2003-12-18
dc.description.abstract Anemometers based on the measurement principle of the fluid velocity using heat transfer and heated electrically thermo-resistive sensor are called Hot wire anemometer. They can be classified as an measurement electrical instrument because the sensor used has one of its electrical parameter modified in presence of the fluid velocity variation. In order to obtain a fluid velocity from a electric parameter one use the electrical equivalence principle in the measurement structures. Among measurement structures that use such a principle, it was investigated the called Constant Temperature Anemometer - CTA. This dissertation consists of establishing a methodology to be used in design of fluid velocity measurement systems based on feedback structures using PWM excitation, beyond procedures for sensor characterization, circuits of fluid temperature compensation and a data acquisition system. Based on the methodology presented in this dissertation, it was developed a CTA with PWM excitation which measures air velocity. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11936
dc.date.accessioned 2020-02-14T15:20:28Z
dc.date.available 2020-02-14
dc.date.available 2020-02-14T15:20:28Z
dc.type Dissertação pt_BR
dc.subject Anemômetro
dc.subject Sensores Termorresistivos
dc.subject Anemômetros a Fio Quente
dc.subject Equivalência Elétrica
dc.subject Ponte de Wheatstone
dc.subject Princípio de Medição da Velocidade do Fluido
dc.subject Anemometer
dc.subject Thermoresistive Sensors
dc.subject Hot Wire Anemometers
dc.subject Electrical Equivalence
dc.subject Wheatstone Bridge
dc.subject Fluid Speed Measurement Principle
dc.rights Acesso Aberto pt_BR
dc.creator DINIZ, Ronny Clay Santos.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Design considerations for hot wire anemometers based on feedback structures. pt_BR
dc.identifier.citation DINIZ, Ronny Clay Santos. Considerações de projeto para anemômetros a fio quente baseado em estruturas realimentadas. 112f. (Dissertação) Mestrado em Engenharia Elétrica, Curso de Pós-Graduação em Engenharia Elétrica, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba – Campus II - Campina Grande - Paraíba - Brasil, 2004. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta