DSpace/Manakin Repository

Reconstrução de tomografia computadorizada através de interpolação baseada em registro.

Mostrar registro simples

dc.creator.ID GUIMARÃES, Daniel Marques Vasconcelos pt_BR
dc.creator.Lattes http://lattes.cnpq.br/4103540054940166 pt_BR
dc.contributor.advisor1 ALMEIDA, Carlos Wilson Dantas de.
dc.contributor.advisor1ID de ALMEIDA, C. W. D. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/5827398788235627 pt_BR
dc.contributor.referee1 GOMES, Herman Martins.
dc.contributor.referee2 PEREIRA, Eanes Torres.
dc.contributor.referee3 SOUSA, Robson Pequeno de.
dc.description.resumo A presença de artefatos metálicos (ruídos) em tomografias computadorizadas atrapalha o diagnóstico médico. Quando uma imagem é reconstruída usando dados incompletos, ocorrem alterações não naturais na aparência, conhecidas como artefatos, que geralmente são observadas como faixas claras ou escuras na imagem. Erros em tomografias computadorizas afetam a capacidade de diagnóstico e dificultam a distinção precisa dos tipos de tecidos, prejudicando o planejamento de radiação para o tratamento de câncer ou de exames de ortopedia ou odontologia, devido à alta qualidade necessária da imagem de tomografia computadorizada. Diversos métodos para redução de artefatos metálicos em imagens médicas foram desenvolvidos nos últimos 40 anos. Esta dissertação propõe um método de interpolação tridimensional baseada em registro entre fatias adjacentes para reconstrução de tomografias computadorizadas. Foram criados artefatos metálicos em tomografias sem ruídos, que afetassem 1, 2, 3, 4, 5 e 9 fatias consecutivas de tomografias computadorizadas, para posterior reconstrução e comparação com o método de interpolação linear clássica, juntamente com outros métodos de recuperação de informações através da transformada de Radon e da Projeção Fanbeam na reconstrução das fatias de tomografias computadorizadas afetadas por artefatos metálicos. Análises quantitativas utilizando as métricas de correlação, PSNR e erro médio absoluto; e análises qualitativas foram realizadas para avaliar o desempenho do método de interpolação baseada em registro. Os resultados mostram que o método proposto apresenta melhores resultados com as métricas citadas anteriormente em relação a interpolação linear a partir da reconstrução de no mínimo 3 fatias consecutivas de tomografia computadorizada. Com a utilização de métodos de interpolação, as tomografias computadorizadas reconstruídas apresentaram o efeito de aliasing, estando este efeito mais atenuado na interpolação baseada em registro do que na interpolação linear. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM CIÊNCIA DA COMPUTAÇÃO pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Ciência da Computação pt_BR
dc.title Reconstrução de tomografia computadorizada através de interpolação baseada em registro. pt_BR
dc.date.issued 2020-08-07
dc.description.abstract The presence of metallic artifacts (noise) in computed tomography disturbs the medical diagnosis. When an image is reconstructed using incomplete data, unnatural changes in appearance occur, known as artifacts, which are usually seen as light or dark bands in the image. Errors in CT scans affect the diagnostic capacity and make it difficult to accurately distinguish the types of tissues, impairing radiation planning for the treatment of cancer, or orthopedics or dentistry exams, due to the high quality required of the CT scan image. Several methods for reducing metallic artifacts in medical images have been developed in the last 40 years. This dissertation proposes a method of three-dimensional interpolation based on registration between adjacent slices for reconstruction of computed tomographies. Metallic artifacts were created in tomography without noise, affecting 1, 2, 3, 4, 5 and 9 consecutive slices of CT scans, for later reconstruction and comparison with the classical linear interpolation method, along with other methods of information retrieval through the Radon transform and the Fanbeam projection in the reconstruction of slices of computed tomography affected by metallic artifacts. Quantitative analyzes using the correlation, PSNR and absolute mean error metrics; and qualitative analyzes were performed to evaluate the performance of the record-based interpolation method. The results show that the proposed method presents better results with the metrics mentioned above in relation to linear interpolation from the reconstruction of at least 3 consecutive slices of computed tomography. With the use of interpolation methods, the reconstructed computed tomographies showed the effect of aliasing, this effect being more attenuated in record-based interpolation than in linear interpolation. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/15894
dc.date.accessioned 2020-10-06T09:15:40Z
dc.date.available 2020-10-06
dc.date.available 2020-10-06T09:15:40Z
dc.type Dissertação pt_BR
dc.subject Computed Tomography pt_BR
dc.subject Tomografia Computadorizada pt_BR
dc.subject Tomografía Computarizada pt_BR
dc.subject Registration-Based Intepolation pt_BR
dc.subject Interpolación Basada en Registros pt_BR
dc.subject Interpolação Baseada em Registro pt_BR
dc.subject Metal Artifacts Reduction pt_BR
dc.subject Redução de Artefatos de Metal pt_BR
dc.subject Reducción de Artefactos Metálicos pt_BR
dc.subject Reconstrução pt_BR
dc.subject Reconstrucción pt_BR
dc.subject Reconstruction pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator GUIMARÃES, Daniel Marques Vasconcelos.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Reconstruction of computed tomography through record-based interpolation. pt_BR
dc.identifier.citation GUIMARÃES, D. M. V. Reconstrução de tomografia computadorizada através de interpolação baseada em registro. 2020. 130 f. Dissertação (Mestrado em Ciência da Computação) Programa de Pós-graduação em Ciência da Computação, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2020. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta