DSpace/Manakin Repository

Dispositivo modificado do desvio para o armazenamento das primeiras águas pluviais para o consumo humano.

Mostrar registro simples

dc.creator.ID FONTES NETO, D. C. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/6330464651515014 pt_BR
dc.contributor.advisor1 OLIVEIRA, Andréa Maria Brandão Mendes de.
dc.contributor.advisor1ID de Oliveira,A.M.B.M. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/7363025139137477 pt_BR
dc.contributor.referee1 SALES, Luís Gustavo de Lima.
dc.contributor.referee2 ARAÚJO FILHO, Felemom Benigno de.
dc.description.resumo Devido à escassez hídrica em regiões semiáridas do Brasil provocada pelas condições geográficas e climáticas, em especial no Nordeste, o problema da falta de água é um constante tema em evidência. Na busca por soluções viáveis e econômicas em tecnologias que permitam conviver com esse quadro, o desvio proposto por Lima (2012), composto por tubos-duto armazenamento com tubulações de diâmetro de 100 milímetros, permite captar e armazenar água de chuva além de tratar a mesma através da redução das partículas sólidas pelo seu princípio de funcionamento que se baseia em conceitos hidráulicos dos vasos comunicantes. No referido trabalho, buscou-se aprimorar esse dispositivo de desvio através da sua redução em 25% do modelo original em um primeiro momento e num segundo adicionando uma esponja de 6 centímetros de espessura em sua saída para o armazenamento de água. Foram simuladas chuva na área de estudo, Casa de Defumação da UFCG-Pombal, com intensidade de 10 mm/hora que permitiram analisar o comportamento dos modelos em três testes para cada protótipo. Foram analisados os parâmetros físico-químicos e microbiológicos de acordo com a Portaria 2914/11 do Ministério da Saúde e notou alguns parâmetros fora da recomendação e outros dentro, porém o modelo reduzido com o filtro de esponja mesmo se destacou na redução da turbidez e coliformes totais, além de obter maior eficiência econômica de custeio e operacional, exemplificando a aplicação desse projeto no Programa Um Milhão de Cisternas do governo federal e mostrando os benefícios que podem ser alcançados com a aplicação dessa tecnologia. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Ciências e Tecnologia Agroalimentar - CCTA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Recursos Florestais e Engenharia Florestal. pt_BR
dc.title Dispositivo modificado do desvio para o armazenamento das primeiras águas pluviais para o consumo humano. pt_BR
dc.date.issued 2017-08-24
dc.description.abstract Due to water scarcity in semi-arid regions of Brazil caused by geographic and climatic conditions, especially in the Northeast, the problem of lack of water is a constant theme. In the search for viable and economical solutions in technologies that allow to confront this situation, the diversion proposed by Lima (2012), composed of duct-storage pipes with pipes of diameter of 100 millimeters, allows to capture and store rainwater besides treating the Through the reduction of solid particles by its operating principle which is based on hydraulic concepts of communicating vessels. In this work, we tried to improve this deviation device by reducing it by 25% of the original model in a first moment and in a second by adding a 6 cm thick sponge in its outlet for water storage. Rainfall was simulated in the study area, UFCG-Pombal House of Smoke, with an intensity of 10 mm / hour that allowed to analyze the behavior of the models in three tests for each prototype. The physico-chemical and microbiological parameters were analyzed according to Ordinance 2914/11 of the Ministry of Health and noted some parameters outside the recommendation and others within, but the reduced model with the sponge filter even stood out in the reduction of turbidity and coliforms In addition to obtaining greater economic cost and operational efficiency, exemplifying the application of this project in the Federal Government's One Million Cisterns Program and showing the benefits that can be achieved with the application of this technology. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18171
dc.date.accessioned 2021-04-16T19:46:52Z
dc.date.available 2021-04-16
dc.date.available 2021-04-16T19:46:52Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Semiárido nordestino pt_BR
dc.subject Northeastern semi-arid pt_BR
dc.subject Água de chuva - captação pt_BR
dc.subject Rainwater - abstraction pt_BR
dc.subject Dispositivo de desvio pt_BR
dc.subject Detour device pt_BR
dc.subject Águas pluviais pt_BR
dc.subject Rainwater pt_BR
dc.subject Eficiência pt_BR
dc.subject Efficiency pt_BR
dc.subject Qualidade da água para fins nobres pt_BR
dc.subject Quality of water for noble purposes pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator FONTES NETO, Djalma da Costa.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Modified diversion device for the storage of the first rainwater for human consumption. pt_BR
dc.identifier.citation FONTES NETO, D. C. Dispositivo modificado do desvio para o armazenamento das primeiras águas pluviais para o consumo humano. 2017. 70 f. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Ambiental) - Centro de Ciências e Tecnologia Agroalimentar, Universidade Federal de Campina Grande, Pombal, Paraíba, Brasil, 2017. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta