Dépôt DSpace/Manakin

Diagnóstico de contatos de disjuntores baseado na resistência dinâmica de contato e Lógica Fuzzy.

Afficher la notice abrégée

dc.creator.ID SOUZA, R. T. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/0855145610768901 pt_BR
dc.contributor.advisor1 COSTA, Edson Guedes da.
dc.contributor.advisor1ID COSTA, E. G. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/3930289115658143 pt_BR
dc.contributor.referee1 SOUZA, Benemar Alencar de.
dc.contributor.referee1ID SOUZA, B. A. pt_BR
dc.contributor.referee2 LOPES, Waslon Terllizzie Araújo.
dc.contributor.referee2ID LOPES, W. T. A. pt_BR
dc.contributor.referee3 ALTAFIM, Ruy Alberto Correa.
dc.contributor.referee3ID ALTAFIM, R. A. C. pt_BR
dc.contributor.referee4 BEZERRA, José Maurício de Barros.
dc.contributor.referee4ID BEZERRA, J. M. B. pt_BR
dc.description.resumo Esta tese apresenta uma nova metodologia para avaliação dos contatos de disjuntores de média e alta tensão, baseando-se na medição da medição de resistência dinâmica (MRD) e lógica FUZZy. Nos testes da MRD, uma curva de resistência é gerada, contemplando valores de resistência de contato referentes às regiões do contato principal e do contato de arco. os testes foram realizados de contatos com disjuntores do tipo PVO (pequeno volume de óleo) de 800 A/15 KV/ 12,5 KA, 630 A /17,5 KV /12,5 KA e 2.000 A/ 72,5 KV /31,5 KA e um disjuntor do tipo SF6 (hexafluoreto de enxofre) de 1.650 A/72,5 KV/ 25 KA. Para realizar os testes da MRD, um sistema de medição foi projetada e desenvolvido. O sistema utiliza um osciloscópio digital de 4 canais, uma bateria estacionária, de 12 V/ 220 Ah, resistências para limitar a corrente da bateria, sensores de corrente e tensão e um computador pessoal. O sistema é capaz de determinar os valores da resistência, desde o início da abertura dos contatos até sua separação total. Nesta pesquisa foi desenvolvido um algoritmo para extrair da MRD, os parâmetros característicos: resistência do contato principal e resistência do contato de arco. Desenvolveu-se também um sistema fundamentado em lógica FUZZY para estimar o nível de degradação contatos em função dos parâmetros da MRD. Em função dos resultados obtidos, observou-se que o nível de degradação dos contatos é diretamente proporcional aos valores de resistência de contato, o que permite um diagnóstico preciso da condição dos contatos principal e de arco. A aplicação da lógica FUZZY permitiu a estimativa do nível de degradação dos contatos. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica. pt_BR
dc.title Diagnóstico de contatos de disjuntores baseado na resistência dinâmica de contato e Lógica Fuzzy. pt_BR
dc.date.issued 2015-09
dc.description.abstract This thesis presents a new methodology for evaluation of high voltage circuit breaker contacts, based on the dynamic resistance measurement (DRM) and fuzzy logic. In the DRM tests, a resistance curve is generated, contemplating resistance values referring to the main and arcing contact regions. The tests were performed with minimum oil circuit breaker (MOCB) of 800 A/15 KV/ 12,5 KA, 630 A/ 17,5 KV/ 12,5 Ka and 2.000 A/ 72,5 KV/ 31,5 KA, and a SF6 circuit breaker of 1.650 A/72,5 KV/ 25 KA. To perform the DRM test, a measurement system has been designed and developed, which consists of a 4-channel digital oscilloscope, a stationary battery of 12 V/ 220 Ah, resistors to limit the current from the battery, current and voltage sensors and a personal computer. The system is able to determine the dynamic resistance values since the beginning of the contact opening process until total separation. In this research, an algorithm was developed to extract from the DRM curves, the characteristic parameters: main contact resistance and arcing contact resistance. A FUZZY logic based system was also developed in order to estimate the contacts degradation level as a function of the DRM parameters. From the obtainned results, it was observed that the contact degradation level is directy proporcional to the resistance values, allowing an accurate diagnosis of the main and arcing contacts condition. The application of FUZZY logic allowed the estimation of the contacts degradation level. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18210
dc.date.accessioned 2021-04-20T19:02:50Z
dc.date.available 2021-04-20
dc.date.available 2021-04-20T19:02:50Z
dc.type Tese pt_BR
dc.subject Contatos de disjuntores pt_BR
dc.subject Resistência dinâmica de contato pt_BR
dc.subject Lógica Fuzzy pt_BR
dc.subject Resistência estática pt_BR
dc.subject Curva de resistência pt_BR
dc.subject Resistência dinâmica pt_BR
dc.subject Disjuntores de alta tensão pt_BR
dc.subject Disjuntores de média tensão pt_BR
dc.subject Câmara de extinção de arco elétrico pt_BR
dc.subject Extinção do arco elétrico pt_BR
dc.subject Circuit breaker contacts pt_BR
dc.subject Dynamic contact resistance pt_BR
dc.subject Fuzzy Logic pt_BR
dc.subject Static resistance pt_BR
dc.subject Resistance curve pt_BR
dc.subject Dynamic resistance pt_BR
dc.subject High voltage circuit breakers pt_BR
dc.subject Medium voltage circuit breakers pt_BR
dc.subject Electric arc extinguishing chamber pt_BR
dc.subject Electric arc extinction pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator SOUZA, Ronimack Trajano de.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Diagnosis of circuit breaker contacts based on dynamic contact resistance and Fuzzy Logic. pt_BR
dc.identifier.citation SOUZA, Ronimack Trajano. Diagnóstico de contatos de disjuntores baseado na resistência dinâmica de contato e Lógica Fuzzy. 2015. 177f. Tese (Doutorado em Engenharia Elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande, Paraíba, Brasil, 2015. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18210 pt_BR


Fichier(s) constituant ce document

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

Chercher dans le dépôt


Recherche avancée

Parcourir

Mon compte