DSpace/Manakin Repository

Utilização de um sensor de campo 3D e métodos estatísticos para diagnóstico de isoladores.

Mostrar registro simples

dc.creator.ID PEDRO, H. J. G. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/9620256708244128 pt_BR
dc.contributor.advisor1 VALLE, Rômulo Raimundo Maranhão do.
dc.contributor.advisor1ID VALLE, R. R. M. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/1442580492932120 pt_BR
dc.contributor.referee1 ALBERT, Bruno Barbosa.
dc.contributor.referee1ID ALBERT, B. B. pt_BR
dc.description.resumo O desempenho de quatro isoladores de linhas de transmissão submetidos a 12 kV foram avaliados considerando a poluição química no qual o isolador foi submetido. Um sistema de processamento e aquisição de dados foi montado, a fim de permitir a classificação do nível de contaminação, identificar a melhor faixa de frequência que contenha a assinatura espectral dos isoladores e investigar qual polarização é mais apropriada para as medições, utilizando uma abordagem estatística. Quando submetido a elevadas tensões, os isoladores irradiam sinais de rádio frequência devido ao efeito corona. Métodos estatísticos como histogramas, teste de normalidade e o coeficiente de correlação foram utilizados para classificar o nível de poluição em isoladores de vidro. Mostra-se que, em determinadas situações os histogramas podem ser usados para distinguir o estado de conservação dos isoladores. Ao utilizar o coeficiente de correlação em conjunto com o teste de normalidade, é possível identificar faixas de frequência de interesse, ou seja, faixas onde a assinatura espectral dos isoladores se encontra. Os testes foram limitados a uma banda de 300 MHz (na de 30 MHz até 330 MHz), pois utilizar bandas maiores aumenta demasiadamente o tempo necessário para aquisição de dados. Foram utilizados dois tipos de antenas: bicônica e isotrópica (sensor 3D). Durante as medições com a antena bicônica, dois tipos de polarização foram empregados, a polarização vertical e horizontal. A escolha de uma antena (bicônica) com um dos tipos de polarização não considera sinais presentes nas demais polarizações, ocasionando perda de informação relevante do sinal irradiado pelos isoladores. Para investigar esse problema uma antena com características especiais foi empregada. Trata-se do sensor 3D (antena isotrópica) que captura o sinal irradiado pelos isoladores nas polarizações segundo os três eixos, fornecendo um único vetor campo elétrico que resume a polarização total incidente. Medições realizadas com o sensor 3D foram confrontadas com as medições realizadas com a antena linear, com o objetivo de verificar qual polarização leva a um melhor casamento com a polarização do sinal irradiado pelos isoladores. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica. pt_BR
dc.title Utilização de um sensor de campo 3D e métodos estatísticos para diagnóstico de isoladores. pt_BR
dc.date.issued 2014-11
dc.description.abstract The insulating performance of four transmission lines subjected to 12 kV were evaluated considering the chemical pollution of the insulator which has undergone. A system of data acquisition and processing was mounted to enable the classification of the level of contamination, to identify the best frequency band containing the spectral signature of the insulators and investigate polarization which is more suitable for measurements using a statistical approach . When subjected to high voltages, the insulator radiate radio frequency signals due to the corona effect. Statistical methods such as histograms, test normality and the correlation coefficient were used to rate the level of pollution in glass insulators. It is shown that in certain situations the histograms can be used to distinguish the condition of the insulators. By using the correlation coefficient in conjunction with the normality test can be identified frequency bands of interest, or bands where the spectral signature is the insulators. Tests were limited to a band of 300 MHz (30 MHz to 330 MHz), for use higher bands excessively increases the time required for data acquisition. Two types of antennas were used: biconical and isotropic (3D sensor). During measurements with the biconical antenna, two types of polarization were used, the vertical and horizontal polarization. The choice of antenna (biconical) with one type of polarization does not consider the signals present in the other polarization, causing loss of relevant information of the signal radiated by insulators. To investigate this problem an antenna with special features was used. This is the 3D sensor (isotropic antenna) that captures the radiated signal by insulators in polarizations based on the three, providing a single electric field vector that summarizes the overall bias incident. Measurements with 3D sensor were compared with measurements made with the linear antenna, in order to find what polarization leads to a better match with the polarization of the radiated signal by insulators. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18385
dc.date.accessioned 2021-04-28T16:35:11Z
dc.date.available 2021-04-28
dc.date.available 2021-04-28T16:35:11Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Sensor de campo 3D pt_BR
dc.subject Diagnóstico de isoladores pt_BR
dc.subject Métodos estatísticos - diagnóstico de isoladores pt_BR
dc.subject Estatística aplicada à Engenharia Elétrica pt_BR
dc.subject Coeficiente de correlação pt_BR
dc.subject Alta tensão pt_BR
dc.subject Histogramas pt_BR
dc.subject Sistema de aquisição de dados pt_BR
dc.subject Isoladores de linhas de transmissão pt_BR
dc.subject Isoladores de vidro - nível de poluição pt_BR
dc.subject Antena bicônica pt_BR
dc.subject Antena isotrópica pt_BR
dc.subject Processamento de dados pt_BR
dc.subject Variáveis qualitativa e quantitativa pt_BR
dc.subject 3D field sensor pt_BR
dc.subject Insulator diagnostics pt_BR
dc.subject Statistical methods - diagnosis of insulators pt_BR
dc.subject Statistics applied to Electrical Engineering pt_BR
dc.subject Correlation coefficient pt_BR
dc.subject High voltage pt_BR
dc.subject Histograms pt_BR
dc.subject Data acquisition system pt_BR
dc.subject Transmission line insulators pt_BR
dc.subject Glass insulators - pollution level pt_BR
dc.subject Biconical antenna pt_BR
dc.subject Isotropic antenna pt_BR
dc.subject Data processing pt_BR
dc.subject Qualitative and quantitative variables pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator PEDRO, Haslan José Gonçalves.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Use of a 3D field sensor and statistical methods for diagnosing insulators. pt_BR
dc.identifier.citation Haslan J. G. Pedro. Utilização de um sensor de campo 3D e métodos estatísticos para diagnóstico de isoladores. 2014. 88f. (Trabalho de Conclusão de Curso - Monografia), Curso de Bacharelado em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba - Brasil, 2014. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18385 pt_BR