DSpace/Manakin Repository

Modelagem de arritmias cardíacas em hardware para validação e avaliação de marca-passos.

Mostrar registro simples

dc.creator.ID MAGALHÃES, G. V. N. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/3741827966416437 pt_BR
dc.contributor.advisor1 SANTOS JÚNIOR, Gutemberg Gonçalves dos.
dc.contributor.advisor1ID SANTOS JÚNIOR, G. G pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/0204301941083935 pt_BR
dc.contributor.referee1 LIMA, Antonio Marcus Nogueira.
dc.contributor.referee1ID LIMA, A. M. N. pt_BR
dc.description.resumo Em décadas passadas, mais de 600.000 dispositivos de estimulação cardíaca sofreram recall, 40% devido a problemas de software [8]. Isso mostra que desenvolver firmwares livres de bugs para esses sistemas ainda é um grande desafio, e que as metodologias usadas para validação não conseguem identificar cenários que levem esses equipamentos a falha. Por serem sistemas críticos, podendo causar danos à saúde dos pacientes ou até mesmo a morte, é de extrema importância desenvolver equipamentos com alto nível de confiabilidade. Isso incentiva, portanto, a formalização de uma metodologia de validação para esses dispositivos. Uma abordagem que se mostra pertinente, é a criação de uma plataforma que simule diferentes condições de batimentos cardíacos e que permita a conexão com marca-passos comerciais, de tal forma a conseguir estimular e detectar falhas nesses sistemas, possibilitando ainda o debug e o levantamento de uma cobertura de testes suficiente para validação de quaisquer desses dispositivos. Além disso, permite também a avaliação da conformidade desses dispositivos pelas Normas Brasileiras para equipamentos eletromédicos implantáveis, em especial, os marca-passos cardíacos. Ademais, a existência de alguns frameworks consagrados pela comunidade acadêmica para modelagem de batimentos cardíacos com e sem arritmias, à exemplo do Virtual Heart Model [2]-[3] desenvolvido pela University of Pennsylvania e disponibilizado de forma gratuita, mostra-se promissor a criação de uma plataforma com os requisitos estabelecidos. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica. pt_BR
dc.title Modelagem de arritmias cardíacas em hardware para validação e avaliação de marca-passos. pt_BR
dc.date.issued 2018
dc.description.abstract In past decades, more than 600,000 cardiac pacing devices have been recalled, 40 % due to software problems [8]. This shows that developing bugs-free firmwares for these systems is still a major challenge, and that the methodologies used for validation can not identify scenarios that lead to such failure. Because they are critical systems that can cause harm to patients’ health or even death, it is extremely important to develop equipment with a high level of reliability. This encourages, therefore, the formalization of a validation methodology for these devices. One approach that is pertinent is the creation of a platform that simulates different heartbeat conditions and allows the connection with commercial pacemakers, so as to be able to stimulate and detect flaws in these systems, also allowing the textit debug and the collection of sufficient test coverage for validation of any of these devices. In addition, it also allows the evaluation of the conformity of these devices by the Brazilian Standards (NBR) for implantable electromedical equipment, especially cardiac pacemakers. In addition, the existence of some frameworks established by the academic community for modeling heartbeats with and without arrhythmias, such as the Virtual Heart Model [2]-[3] developed by the University of Pennsylvania, is available free of charge. promising the creation of a platform with the established requirements. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18867
dc.date.accessioned 2021-05-18T19:52:13Z
dc.date.available 2021-05-18
dc.date.available 2021-05-18T19:52:13Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Modelagem de arritmias cardíacas pt_BR
dc.subject Marca-passos avaliação pt_BR
dc.subject Tecnologia aplicada à cardiologia pt_BR
dc.subject Cardiologia - tecnologia pt_BR
dc.subject Dispositivos médicos pt_BR
dc.subject Sistemas de tempo real pt_BR
dc.subject Sistemas cíber-físicos pt_BR
dc.subject Autômatos pt_BR
dc.subject Virtual Heart Model - VHM pt_BR
dc.subject Coração - sistema de condução elétrico pt_BR
dc.subject Pacemaker Verification System pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator MAGALHÃES, Gabriel Villanova Novaes.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Hardware cardiac arrhythmias modeling for pacemaker validation and evaluation. pt_BR
dc.identifier.citation MAGALHÃES, Gabriel Villanova Novaes. Modelagem de arritmias cardíacas em hardware para validação e avaliação de marca-passos. 2018. 68f. (Trabalho de Conclusão de Curso - Monografia), Curso de Bacharelado em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba - Brasil, 2018. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/18867 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta