dc.creator.ID |
CAMPOS, M. |
pt_BR |
dc.creator.Lattes |
http://lattes.cnpq.br/7207601062237405 |
pt_BR |
dc.contributor.advisor1 |
LIMA, Antonio Marcus Nogueira. |
|
dc.contributor.advisor1ID |
LIMA, A. M. N. |
pt_BR |
dc.contributor.advisor1Lattes |
http://lattes.cnpq.br/2237395961717699 |
pt_BR |
dc.contributor.advisor2 |
OLIVEIRA, Alexandre Cunha. |
|
dc.contributor.advisor2ID |
OLIVEIRA, A. C. |
pt_BR |
dc.contributor.advisor2Lattes |
http://lattes.cnpq.br/6699829609793478 |
pt_BR |
dc.contributor.referee1 |
CANHA, Luciane Neves. |
|
dc.contributor.referee2 |
SOUZA, Benemar Alencar de. |
|
dc.contributor.referee3 |
JACOBINA, Cursino Brandão. |
|
dc.contributor.referee4 |
COSTA, Flávio Bezerra. |
|
dc.description.resumo |
De uma forma geral todos sistemas elétricos estão susceptíveis a faltas. Todavia, existem faltas
que não são detectadas pelo sistema de proteção, como por exemplo, a causada por galhos
de árvores que tocam a rede elétrica ou ainda um rompimento de cabo sob uma superfície
isolante tal como asfalto. Estas faltas são conhecidas como faltas de alta impedância (FAI).
As FAI se apresentam como um desafio e normalmente não são detectadas pela proteção
do sistema. Neste trabalho, foi realizado um estudo detalhado de técnicas de detecção de
FAI apresentadas na literatura, identificando-se as condições em que cada uma apresenta
melhor comportamento em termos de detecção, bem como as eventuais deficiências de cada
uma das técnicas estudadas. As técnicas existentes podem ser classificadas em Passivas e
Ativas. Das técnicas passivas foram escolhidas cinco para que fosse realizado um estudo
comparativo de forma equilibrada partindo-se de um mesmo cenário e avaliando todas as
técnicas sob as mesmas condições de análise. Uma técnica ativa também foi estudada, sob
a ótica principalmente de desempenho. Baseado em todos estes estudos, foi proposta uma
alteração da técnica ativa, esta modificação resultou em um melhor desempenho comparado
a original. Para completar este estudo, este trabalho apresenta uma metodologia para a
combinação das técnicas passivas de detecção de FAI. A técnica baseada na observação dos
Harmônicos de baixa ordem de sequência negativa, foi combinada transformada wavelets.
Por fim, foi utilizada uma rede neural artificial para que produzisse um diagnóstico, uma
vez que é necessária a combinação de dois resultados para permitir a detecção precisa da
condição de falta. Esta metodologia permitiu a distinção dos eventos do sistema e a correta
detecção das faltas em todos os casos. |
pt_BR |
dc.publisher.country |
Brasil |
pt_BR |
dc.publisher.department |
Centro de Engenharia Elétrica e Informática - CEEI |
pt_BR |
dc.publisher.program |
PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA |
pt_BR |
dc.publisher.initials |
UFCG |
pt_BR |
dc.subject.cnpq |
Engenharia Elétrica. |
pt_BR |
dc.title |
Detecção de faltas de alta impedância em sistemas de distribuição primários de energia elétrica. |
pt_BR |
dc.date.issued |
2017-12-07 |
|
dc.description.abstract |
In general, all electrical systems are susceptible to failure. However, there are faults that are
not detected by the protection system, such as those caused by tree branches that hit the
power grid or a cable break under an insulating surface such as asphalt. These faults are
known as high impedance faults (HIF). HIF present themselves as a challenge and cannot
be detected by traditional methods. In this work, a detailed study of detection techniques
for high impedance faults presented in technical literature was carried out, identifying the
conditions in which each improves detection behavior as well as possible deficiencies in each
technique studied. The techniques existing in the literature can be classified as either passive
or active. From the passive techniques present in the literature, five were chosen so that a
comparative study could be carried out in a balanced way, starting with the same scenario
and evaluating all the techniques under the same conditions. An active technique has also
been studied from the standpoint of performance in terms of detectability and type of fault.
Based on all these studies a change was proposed in the active technique. These modifications
resulted in improved performance compared to the original. In order to complete this study,
this work presents the possibility of combining the passive techniques for detecting HIF.
The technique based on the observation of low order harmonics of negative sequence was
combined with the technique based on wavelets. An artificial neural network was used to
produce a final result, since it is necessary to combine two results to allow precise diagnosis
of the fault condition. This combination allowed the detectors to distinguish the events in
the system and correct detection of the faults in all cases. |
pt_BR |
dc.identifier.uri |
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19984 |
|
dc.date.accessioned |
2021-07-12T16:54:18Z |
|
dc.date.available |
2021-07-12 |
|
dc.date.available |
2021-07-12T16:54:18Z |
|
dc.type |
Tese |
pt_BR |
dc.subject |
Faltas em sistemas de distribuição elétricos |
pt_BR |
dc.subject |
Faltas de alta impedância - detecção |
pt_BR |
dc.subject |
Sistemas de distribuição primários |
pt_BR |
dc.subject |
Processamento de energia |
pt_BR |
dc.subject |
Modelagem do sistema de distribuição de energia |
pt_BR |
dc.subject |
Métodos de detecção de faltas |
pt_BR |
dc.subject |
Detecção de falta de alta impedância por assinatura |
pt_BR |
dc.subject |
Harmônicos de baixa ordem |
pt_BR |
dc.subject |
Transformada de Wavelets |
pt_BR |
dc.subject |
Redes neurais artificiais |
pt_BR |
dc.subject |
Faults in electrical distribution systems |
pt_BR |
dc.subject |
High impedance faults - detection |
pt_BR |
dc.subject |
Primary distribution systems |
pt_BR |
dc.subject |
Energy processing |
pt_BR |
dc.subject |
Modeling the power distribution system |
pt_BR |
dc.subject |
Fault Detection Methods |
pt_BR |
dc.subject |
Signature High Impedance Miss Detection |
pt_BR |
dc.subject |
Low order harmonics |
pt_BR |
dc.subject |
Wavelets Transform |
pt_BR |
dc.subject |
Artificial neural networks |
pt_BR |
dc.rights |
Acesso Aberto |
pt_BR |
dc.creator |
CAMPOS, Maurício de. |
|
dc.publisher |
Universidade Federal de Campina Grande |
pt_BR |
dc.language |
por |
pt_BR |
dc.title.alternative |
Detection of high impedance faults in primary power distribution systems. |
pt_BR |
dc.identifier.citation |
CAMPOS, Maurício de. Detecção de faltas de alta impedância em sistemas de distribuição primários de energia elétrica. 2017. 151f. (Tese de Doutorado) Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2017. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19984 |
pt_BR |