DSpace/Manakin Repository

Detecção de faltas de alta impedância em sistemas de distribuição primários de energia elétrica.

Mostrar registro simples

dc.creator.ID CAMPOS, M. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/7207601062237405 pt_BR
dc.contributor.advisor1 LIMA, Antonio Marcus Nogueira.
dc.contributor.advisor1ID LIMA, A. M. N. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/2237395961717699 pt_BR
dc.contributor.advisor2 OLIVEIRA, Alexandre Cunha.
dc.contributor.advisor2ID OLIVEIRA, A. C. pt_BR
dc.contributor.advisor2Lattes http://lattes.cnpq.br/6699829609793478 pt_BR
dc.contributor.referee1 CANHA, Luciane Neves.
dc.contributor.referee2 SOUZA, Benemar Alencar de.
dc.contributor.referee3 JACOBINA, Cursino Brandão.
dc.contributor.referee4 COSTA, Flávio Bezerra.
dc.description.resumo De uma forma geral todos sistemas elétricos estão susceptíveis a faltas. Todavia, existem faltas que não são detectadas pelo sistema de proteção, como por exemplo, a causada por galhos de árvores que tocam a rede elétrica ou ainda um rompimento de cabo sob uma superfície isolante tal como asfalto. Estas faltas são conhecidas como faltas de alta impedância (FAI). As FAI se apresentam como um desafio e normalmente não são detectadas pela proteção do sistema. Neste trabalho, foi realizado um estudo detalhado de técnicas de detecção de FAI apresentadas na literatura, identificando-se as condições em que cada uma apresenta melhor comportamento em termos de detecção, bem como as eventuais deficiências de cada uma das técnicas estudadas. As técnicas existentes podem ser classificadas em Passivas e Ativas. Das técnicas passivas foram escolhidas cinco para que fosse realizado um estudo comparativo de forma equilibrada partindo-se de um mesmo cenário e avaliando todas as técnicas sob as mesmas condições de análise. Uma técnica ativa também foi estudada, sob a ótica principalmente de desempenho. Baseado em todos estes estudos, foi proposta uma alteração da técnica ativa, esta modificação resultou em um melhor desempenho comparado a original. Para completar este estudo, este trabalho apresenta uma metodologia para a combinação das técnicas passivas de detecção de FAI. A técnica baseada na observação dos Harmônicos de baixa ordem de sequência negativa, foi combinada transformada wavelets. Por fim, foi utilizada uma rede neural artificial para que produzisse um diagnóstico, uma vez que é necessária a combinação de dois resultados para permitir a detecção precisa da condição de falta. Esta metodologia permitiu a distinção dos eventos do sistema e a correta detecção das faltas em todos os casos. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica. pt_BR
dc.title Detecção de faltas de alta impedância em sistemas de distribuição primários de energia elétrica. pt_BR
dc.date.issued 2017-12-07
dc.description.abstract In general, all electrical systems are susceptible to failure. However, there are faults that are not detected by the protection system, such as those caused by tree branches that hit the power grid or a cable break under an insulating surface such as asphalt. These faults are known as high impedance faults (HIF). HIF present themselves as a challenge and cannot be detected by traditional methods. In this work, a detailed study of detection techniques for high impedance faults presented in technical literature was carried out, identifying the conditions in which each improves detection behavior as well as possible deficiencies in each technique studied. The techniques existing in the literature can be classified as either passive or active. From the passive techniques present in the literature, five were chosen so that a comparative study could be carried out in a balanced way, starting with the same scenario and evaluating all the techniques under the same conditions. An active technique has also been studied from the standpoint of performance in terms of detectability and type of fault. Based on all these studies a change was proposed in the active technique. These modifications resulted in improved performance compared to the original. In order to complete this study, this work presents the possibility of combining the passive techniques for detecting HIF. The technique based on the observation of low order harmonics of negative sequence was combined with the technique based on wavelets. An artificial neural network was used to produce a final result, since it is necessary to combine two results to allow precise diagnosis of the fault condition. This combination allowed the detectors to distinguish the events in the system and correct detection of the faults in all cases. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19984
dc.date.accessioned 2021-07-12T16:54:18Z
dc.date.available 2021-07-12
dc.date.available 2021-07-12T16:54:18Z
dc.type Tese pt_BR
dc.subject Faltas em sistemas de distribuição elétricos pt_BR
dc.subject Faltas de alta impedância - detecção pt_BR
dc.subject Sistemas de distribuição primários pt_BR
dc.subject Processamento de energia pt_BR
dc.subject Modelagem do sistema de distribuição de energia pt_BR
dc.subject Métodos de detecção de faltas pt_BR
dc.subject Detecção de falta de alta impedância por assinatura pt_BR
dc.subject Harmônicos de baixa ordem pt_BR
dc.subject Transformada de Wavelets pt_BR
dc.subject Redes neurais artificiais pt_BR
dc.subject Faults in electrical distribution systems pt_BR
dc.subject High impedance faults - detection pt_BR
dc.subject Primary distribution systems pt_BR
dc.subject Energy processing pt_BR
dc.subject Modeling the power distribution system pt_BR
dc.subject Fault Detection Methods pt_BR
dc.subject Signature High Impedance Miss Detection pt_BR
dc.subject Low order harmonics pt_BR
dc.subject Wavelets Transform pt_BR
dc.subject Artificial neural networks pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator CAMPOS, Maurício de.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Detection of high impedance faults in primary power distribution systems. pt_BR
dc.identifier.citation CAMPOS, Maurício de. Detecção de faltas de alta impedância em sistemas de distribuição primários de energia elétrica. 2017. 151f. (Tese de Doutorado) Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2017. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/19984 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta